Product
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0Handling Company
Krone Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Applicable tube outer diameter x inner diameter (mm) | Body material | Calibration fluid | Current consumption current | Digital input | Dimension CH X CW (mm) | Dimension L X W X H (HWH) (mm) | Flow range (ML/Min) | Fluid temperature/environmental temperature | Measured fluid | Measurement accuracy | Output connector | Output signal | Power-supply voltage | Protection grade | option | storage temperature | terms of use | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Co55/035SD v2.0 |
Available upon quote | 4.0 x 3.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 3.5 | 44 x 64 x 31 | 300 ~ 3,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
380 | |
Co55/060SD v2.0 |
Available upon quote | 7.0 x 5.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 6.0 | 44 x 64 x 33 | 600 ~ 6,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
420 | |
Co55/080SD v2.0 |
Available upon quote | 9.0 x 6.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 8.0 | 44 x 64 x 35 | 800 ~ 8,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
430 | |
Co55/100SD v2.0 |
Available upon quote | 12.0 x 9.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 10.0 | 44 x 64 x 38 | 1,000-10,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
480 | |
Co55/120SD v2.0 |
Available upon quote | 14.0 x 10.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 12.0 | 44 x 64 x 40 | 1,200 ~ 12,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
500 | |
Co55/140SD v2.0 |
Available upon quote | 16.0 x 12.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 14.0 | 44 x 64 x 42 | 1,400 ~ 14,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
520 | |
Co55/160SD v2.0 |
Available upon quote | 19.0 x 14.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 16.0 | 44 x 64 x 45 | 1,800 ~ 18,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
540 | |
Co55/190SDH v2.0 |
Available upon quote | 22.0 x 16.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 19.0 | 50 x 88 x 43 (64) | 4,000 to 40,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
800 | |
Co55/230SDH v2.0 |
Available upon quote | 25.4 x 15.9 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 23.0 | 50 x 88 x 45 (66) | 5,000 ~ 50,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
800 | |
Co55/260SDH v2.0 |
Available upon quote | 28.6 x 19.0 |
Measurement unit: PMMA Housing: SUS303 * Options: Stainless steel, plastic |
Water (23 ± 2 ℃) * Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request. |
Up to 50 ma | Free configuration: zero point calibration and administration start signal (MAX 30V) | □ 26.0 | 50 x 88 x 47 (68) | 7,000 ~ 50,000 | 0 to 60 ° C | Water, transparent liquid | ± 2 % RD | 8-pin M12 connector (din en 61076-2-101: 2012) |
0/4-20 MA analog output Frequency output: 0 ~ 20 kHz RS-485 Communication (SONOTEC protocol, option MODBUS®) Switching output: pnp/npn/push-pull |
12 ~ 30VDC | IP65 |
Sensor cable 2 meters or 5m Calibration certificate SONOFLOW C3 software |
-20 ~ 70 ° C |
Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE Tube outer diameter: 4-35 mm |
800 |
Click on the part number for more information about each product