Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Co55/035SD v2.0
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Krone Co., Ltd.

Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0
Krone Co., Ltd.


About This Product

■ Characteristics ・ The SONOFLOW® Co55/XXXSD (H) series is an integrated model of the co55 series. -Contracted analog output and frequency output are also standard equipment, supporting applications in various fields. ・ RS-485 communication (SONOTEC protocol, modbus® with software settings), up to 12 sensors in a harsh environment ・ Compact, all -in -one ultrasonic flow meter that enables bus operation. ■ Applications Measurement of flow rate of artificial cardiopulmonary and dialysis devices, etc. * There are other model numbers.

  • Product

    Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0

Share this product


880+ people viewing

Last viewed: 37 minutes ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Applicable tube outer diameter x inner diameter (mm) Body material Calibration fluid Current consumption current Digital input Dimension CH X CW (mm) Dimension L X W X H (HWH) (mm) Flow range (ML/Min) Fluid temperature/environmental temperature Measured fluid Measurement accuracy Output connector Output signal Power-supply voltage Protection grade option storage temperature terms of use weight
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/035SD v2.0

Co55/035SD v2.0

Available upon quote 4.0 x 3.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 3.5 44 x 64 x 31 300 ~ 3,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
380
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/060SD v2.0

Co55/060SD v2.0

Available upon quote 7.0 x 5.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 6.0 44 x 64 x 33 600 ~ 6,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
420
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/080SD v2.0

Co55/080SD v2.0

Available upon quote 9.0 x 6.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 8.0 44 x 64 x 35 800 ~ 8,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
430
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/100SD v2.0

Co55/100SD v2.0

Available upon quote 12.0 x 9.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 10.0 44 x 64 x 38 1,000-10,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
480
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/120SD v2.0

Co55/120SD v2.0

Available upon quote 14.0 x 10.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 12.0 44 x 64 x 40 1,200 ~ 12,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
500
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/140SD v2.0

Co55/140SD v2.0

Available upon quote 16.0 x 12.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 14.0 44 x 64 x 42 1,400 ~ 14,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
520
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/160SD v2.0

Co55/160SD v2.0

Available upon quote 19.0 x 14.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 16.0 44 x 64 x 45 1,800 ~ 18,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
540
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/190SDH v2.0

Co55/190SDH v2.0

Available upon quote 22.0 x 16.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 19.0 50 x 88 x 43 (64) 4,000 to 40,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
800
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/230SDH v2.0

Co55/230SDH v2.0

Available upon quote 25.4 x 15.9 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 23.0 50 x 88 x 45 (66) 5,000 ~ 50,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
800
Ultrasonic flow meter for clamp -on tubes SONOFLOW CO.55/XXXSD (H) v2.0-Part Number-Co55/260SDH v2.0

Co55/260SDH v2.0

Available upon quote 28.6 x 19.0 Measurement unit: PMMA
Housing: SUS303 * Options: Stainless steel, plastic
Water (23 ± 2 ℃)
* Calonization will be performed on your tube, fluid, flow range, temperature, etc. according to your request.
Up to 50 ma Free configuration: zero point calibration and administration start signal (MAX 30V) □ 26.0 50 x 88 x 47 (68) 7,000 ~ 50,000 0 to 60 ° C Water, transparent liquid ± 2 % RD 8-pin M12 connector (din en 61076-2-101: 2012) 0/4-20 MA analog output
Frequency output: 0 ~ 20 kHz
RS-485 Communication (SONOTEC protocol, option MODBUS®)
Switching output: pnp/npn/push-pull
12 ~ 30VDC IP65 Sensor cable 2 meters or 5m
Calibration certificate
SONOFLOW C3 software
-20 ~ 70 ° C Tube material: PVC, silicon, PTFE, PFA, FEP, TPE, Tigon, PE
Tube outer diameter: 4-35 mm
800

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Krone Co., Ltd.


View more products of Krone Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree