Product
Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA seriesHandling Company
Krone Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Long -term stability | Measurement accuracy | Measurement medium | Operating temperature limit | Pressure range | Sample rate | Save temperature range | output | power supply | resolution | type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HPB200 |
Available upon quote | Up to 0.25 HPA/year | <± 0.4hpa | General (non -corrosive) | -40 ℃ ~ 85 ℃ | 500 ~ 1,200 hpa | Select within 8.33ms to 51.2min | -55 ℃ ~ 90 ° C | TTL, RS232, RS485 |
6.26VDC (TTL) 5.5 ~ 30VDC (RS-232, RS-485) |
0.0011% F.S | barometer | |
HPA200 |
Available upon quote | Up to 0.02 % F.S/year | <± 0.03%FS | General (non -corrosive) | -40 ℃ ~ 85 ℃ | 0 ~ 1,213.47hpa | Select within 8.33ms to 51.2min | -55 ℃ ~ 90 ° C | TTL, RS232, RS485 |
6.26VDC (TTL) 5.5 ~ 30VDC (RS-232, RS-485) |
0.0011% F.S | Altitude | |
HPB100 |
Available upon quote | Up to 0.25 HPA/year | <± 0.8hpa | General (non -corrosive) | -40 ℃ ~ 85 ℃ | 500 ~ 1,200 hpa | Select within 8.33ms to 51.2min | -55 ℃ ~ 90 ° C | TTL, RS232, RS485 |
6.26VDC (TTL) 5.5 ~ 30VDC (RS-232, RS-485) |
0.0011% F.S | barometer | |
HPA100 |
Available upon quote | Up to 0.02 % F.S/year | <± 0.06%FS | General (non -corrosive) | -40 ℃ ~ 85 ℃ | 0 ~ 1,213.47hpa | Select within 8.33ms to 51.2min | -55 ℃ ~ 90 ° C | TTL, RS232, RS485 |
6.26VDC (TTL) 5.5 ~ 30VDC (RS-232, RS-485) |
0.0011% F.S | Altitude |
Click on the part number for more information about each product