Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series-HPB200
Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series-Krone Co., Ltd.

Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series
Krone Co., Ltd.


About This Product

■ Characteristics The HPB / HPA series can be high-precision pressure and absolute pressure measurement under the severe environmental temperature conditions of -40 to 85 ° C. , HPA for absolute pressure monitor is ± 0.03%FS (MAX). The output can be selected from TTL, RS232, RS485, has excellent long -term stability, and is used for data collection in environmental test equipment.

  • Product

    Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series




*Please note that we may not be able to accommodate sample requests.

4 Models of Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Long -term stability Measurement accuracy Measurement medium Operating temperature limit Pressure range Sample rate Save temperature range output power supply resolution type
Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series-Part Number-HPB200

HPB200

Available upon quote Up to 0.25 HPA/year <± 0.4hpa General (non -corrosive) -40 ℃ ~ 85 ℃ 500 ~ 1,200 hpa Select within 8.33ms to 51.2min -55 ℃ ~ 90 ° C TTL, RS232, RS485 6.26VDC (TTL)
5.5 ~ 30VDC (RS-232, RS-485)
0.0011% F.S barometer
Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series-Part Number-HPA200

HPA200

Available upon quote Up to 0.02 % F.S/year <± 0.03%FS General (non -corrosive) -40 ℃ ~ 85 ℃ 0 ~ 1,213.47hpa Select within 8.33ms to 51.2min -55 ℃ ~ 90 ° C TTL, RS232, RS485 6.26VDC (TTL)
5.5 ~ 30VDC (RS-232, RS-485)
0.0011% F.S Altitude
Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series-Part Number-HPB100

HPB100

Available upon quote Up to 0.25 HPA/year <± 0.8hpa General (non -corrosive) -40 ℃ ~ 85 ℃ 500 ~ 1,200 hpa Select within 8.33ms to 51.2min -55 ℃ ~ 90 ° C TTL, RS232, RS485 6.26VDC (TTL)
5.5 ~ 30VDC (RS-232, RS-485)
0.0011% F.S barometer
Overall accuracy ± 0.4hpa / ± 0.03% semiconductor pressure transduca F.S HPB / HPA series-Part Number-HPA100

HPA100

Available upon quote Up to 0.02 % F.S/year <± 0.06%FS General (non -corrosive) -40 ℃ ~ 85 ℃ 0 ~ 1,213.47hpa Select within 8.33ms to 51.2min -55 ℃ ~ 90 ° C TTL, RS232, RS485 6.26VDC (TTL)
5.5 ~ 30VDC (RS-232, RS-485)
0.0011% F.S Altitude

Click on the part number for more information about each product