Product
General -purpose joint seatHandling Company
Ask TechnicaItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | 50% LLC_ mass increase rate (%) | 50% LLC_ thickness increase (%) | Compression characteristic_Rumable compression rate (%) | Compression characteristics _ Recovery rate (%) | Fuel B_ Increase thickness (%) | Fuel B_ mass increase rate (%) | IRM903 OIL_ mass increase rate (%) | IRM903 OIL_ thickness increase (%) | SSA-EB1ML2P-12ED1Q8 (0) | SSA-EB1MLGRP-12ED1Q8 (0) | SSA-EB1MLP-12ED1Q8 (0) | SSA-EB1MLXRP-12ED1Q8 (0) | SSA-EB1MLYRP-12ED1Q8 (0) | SSA-EB1MP-02ED1Q4 (0) | SSA-EB1MP-02ED1Q5A (0) | SSA-EB1MP-02ED1Q5B (0) | SSA-EB1MP-11ED1Q4 (0) | SSA-EB1MP-22ED1Q8 (0) | SSA-EB1P-02 (0) | SSA-EB1P-02-A01 (0) | SSA-ISD-TCA | Si-RFPT-H2M (0) | Si-RFPT-HP5 (0) | Si-RFPT-L2M (0) | Si-RFPT-LP5 (0) | Si-RFPT-U2M (0) | Si-RFPT-UP5 (0) | Si-RFSL-HP8 | Si-RFSL-LP8 | Si-RFSL-UP8 | Si-RFST-HP8 | Si-RFST-LP8 | Si-RFST-UP8 | Strength easing rate (%) | Tensile strength (MPA) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4600 |
Available upon quote | 9 | 3 | Ten | 62 | Four | Ten | 11 | 3 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Non -contact safety sensor corresponding to individual applications Coding type: High Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor corresponding to individual applications Coding type: High Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor corresponding to individual applications Coding type: Low Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor corresponding to individual applications Coding type: Low Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor corresponding to individual applications Coding type: Clear Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor corresponding to individual applications Coding type: Clear Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
- | - | - | - | - | - | 29 | 16 | |
4607 |
Available upon quote | Ten | Four | 9 | 61 | 12 | 16 | 20 | 13 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Non -contact safety sensor for cascade Coding type: High Reset: Lock Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: Low Reset: Lock Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: Clear Reset: Lock Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: High Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: Low Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: Clear Reset: Automatic Diagnosis: PNP output (not safety -related) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
twenty four | 16 | |
4612 |
Available upon quote | - | - | 7 | 58 | 6 | Five | Five | Five | - | - | - | - | - | - | - | - | - | - | - | - |
T adapter for ISD cascade Connect an incompatible ISD device in the existing ISD cascade Input: Standard safety switch with two NC contacts Up to 32 devices in the cascade network 1 × Diagnosis input Providing comprehensive diagnostic information LED display for input signals and ISD status |
- | - | - | - | - | - | - | - | - | - | - | - | twenty five | 13 | |
4636 |
Available upon quote | 6 | Four | Ten | 60 | 9 | 8 | 9 | 8 |
Emergency shutdown Emergency stop switch With rectangle, lock Protection grade IP65 Two safety output (NC, no voltage) Auxiliary output 1 point (No, PNP) M12 × 1 Osconector, 8 pins |
Emergency shutdown Emergency stop switch With rectangle, lock Protection grade IP65 Non -operating lighting: Green lighting Lighting circuit is interrupted from outside: red lighting Operation lighting: Red lighting Two safety output (NC, no voltage) Auxiliary output 1 point (No, PNP) M12 × 1 Osconector, 8 pins |
Emergency shutdown Emergency stop switch With rectangle, lock Protection grade IP65 LED red (lighting) Two safety output (NC, no voltage) Auxiliary output 1 point (No, PNP) M12 × 1 Osconector, 8 pins |
Emergency shutdown Emergency stop switch With rectangle, lock Protection grade IP65 Non -operating lighting: None Lighting circuit is interrupted from outside: red lighting Operation lighting: Red lighting Two safety output (NC, no voltage) Auxiliary output 1 point (No, PNP) M12 × 1 Osconector, 8 pins |
Emergency shutdown Emergency stop switch With rectangle, lock Protection grade IP65 Non -operating lighting: Yellow lighting Lighting circuit is interrupted from outside: red lighting Operation lighting: Red lighting Two safety output (NC, no voltage) Auxiliary output 1 point (No, PNP) M12 × 1 Osconector, 8 pins |
Emergency shutdown Emergency stop switch With rectangle, lock Protection grade IP65 Two safety output (NC, no voltage) M12 × 1 Osconector, 4 -pin |
- | - |
Emergency shutdown Emergency stop switch With rectangle, lock Protection grade IP65 One safety output (NC, no voltage) Auxiliary output 1 point (No, PNP) M12 × 1 Osconector, 4 -pin |
Emergency shutdown Emergency stop switch With rectangle, lock Protection grade IP65 Two safety output (NC, no voltage) Auxiliary output 2 points (No, PNP) M12 × 1 Osconector, 8 pins |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 19 | 26 | |
4652 |
Available upon quote | 27 | 30 | 11 | 58 | 7 | 13 | 14 | 8 | - | - | - | - | - | - |
Emergency shutdown Emergency stop switch Two safety output (NC, no voltage) M12 × 1 Osconector, 5 -pin |
Emergency shutdown Emergency stop switch Protection grade IP65 Compatible with Siemenset200proprofisafe Gateway Two safety output (NC, no voltage) M12 × 1 Osconector, 5 -pin |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 30 | 13 | |
4660 |
Available upon quote | 7 | 6 | 13 | 58 | 18 | 11 | 17 | twenty five | - | - | - | - | - | - | - | - | - | - |
Emergency shutdown Emergency stop button 30mm mounting console installation Two NC contacts 40mm actuator Push and turn operation for emergency stop/release |
Emergency shutdown Emergency stop button 30mm mounting console installation Two NC contacts 40mm actuator Push and turn operation for emergency stop/release Two safety output (NC, no voltage) M12 x 1 connector, 5 -pin |
- | - | - | - | - | - | - | - | - | - | - | - | - | 32 | 12 |
Click on the part number for more information about each product