Product
Industrial machine brake and clutchHandling Company
Ask TechnicaItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Example of use in the general industrial field | Recommended application _ for braking | Recommended application _ for conduction | Recommended purpose _ For holding | Si-QS90E-Q5A () | Si-RF-A () | Si-RFA-DM1 () | Si-RFA-DM2 | Si-RFDL-HP8 | Si-RFDL-LP8 | Si-RFDL-UP8 | Si-RFDT-HP8 | Si-RFDT-LP8 | Si-RFDT-UP8 | Si-magb1smqd () | Si-magb2mm () | Si-magb2smqd () | Si-magb3mm () | Si-magb3smqd () | μ rank |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Km84 |
Available upon quote |
Electromagnetic brake General-purpose products Many other results |
◯ | ◯ | ◯ | - | - | - | - | - | - | - | - | - | - |
Non -contact switch Prevention of tampering with coded magnets Needed coded magnet SI-MAGB1mm for operation SIL3 (IEC61508) PLE (ISO13849-1) 1 point of contact (NC) 1 point Normal opening (NO) 1 point of contact |
- | - | - | - | Middle μ | |
CN18 |
Available upon quote |
Electromagnetic brake Torque minister Friction washer |
◯ | ◯ | - | - | - | - | - | - | - | - | - | - | - | - |
Prevention of unauthorized operation Magnetic safety switch SI-MAGB2SMXX is required for operation. |
- | - | - | Low Low μ | |
CN25 |
Available upon quote |
Outboard motor Torque minister |
- | ◯ | ◯ | - | - | - | - | - | - | - | - | - | - | - | - |
Non -contact switch Prevention of tampering with coded magnets Needed coded magnet SI-MAGB2mm for operation SIL3 (IEC61508) PLE (ISO13849-1) 1 point of contact (NC) 1 point Normal opening (NO) 1 point of contact |
- | - | Low Low μ | |
CN80 |
Available upon quote | Electromagnetic brake | ◯ | ◯ | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Prevention of unauthorized operation Magnetic safety switch SI-MAGB3SMXX is required for operation. |
- | Middle μ | |
ND8 |
Available upon quote | Drum -type electromagnetic brake | ◯ | - | ◯ | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Non -contact switch Prevention of tampering with coded magnets Needed coded magnet SI-MAGB3mm for operation SIL3 (IEC61508) PLE (ISO13849-1) 1 point of contact (NC) 1 point Normal opening (NO) 1 point of contact |
Middle μ | |
No183 |
Available upon quote |
Brake in oil Torque minister Lever hold brake |
◯ | ◯ | ◯ |
Limit switch IEC60947-5-1 conformity |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | Middle μ | |
Na13 |
Available upon quote |
Electromagnetic brake Robot holding brake |
◯ | ◯ | ◯ | - |
Prevention of unauthorized operation RFID safety switch SI-RFXXX is required for operation. |
- | - | - | - | - | - | - | - | - | - | - | - | - | Middle μ | |
EP9 |
Available upon quote |
Emergency brake Holding brake |
- | - | ◯ | - | - |
Safety RFID switch diagnosis module 1 × Diagnosis input 8 × PNP status output Providing comprehensive diagnostic information Acquire diagnostic information via IO-Link or USB interface For RFID switch SI-RFDXXX with continuous diagnosis (ISD) |
- | - | - | - | - | - | - | - | - | - | - | - | High High μ | |
CNK31 |
Available upon quote |
Brake in oil Oiled clutch |
◯ | ◯ | - | - | - | - |
Diagnosis module for safety switches with ISD function 1 × Diagnosis input Providing comprehensive diagnostic information Acquire diagnostic information via IO-Link or USB interface |
- | - | - | - | - | - | - | - | - | - | - | Low Low μ | |
RM07 |
Available upon quote | Electromagnetic brake | ◯ | - | ◯ | - | - | - | - |
Non -contact safety sensor for cascade Coding type: High Reset: Lock Diagnosis: Detailed ISD (continuous diagnosis) diagnosis system that provides complete status images (not related to safety) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: Low Reset: Lock Diagnosis: Detailed ISD (continuous diagnosis) diagnosis system that provides complete status images (not related to safety) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: Clear Reset: Lock Diagnosis: Detailed ISD (continuous diagnosis) diagnosis system that provides complete status images (not related to safety) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: High Reset: Automatic Diagnosis: Detailed ISD (continuous diagnosis) diagnosis system that provides complete status images (not related to safety) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: Low Reset: Automatic Diagnosis: Detailed ISD (continuous diagnosis) diagnosis system that provides complete status images (not related to safety) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
Non -contact safety sensor for cascade Coding type: Clear Reset: Automatic Diagnosis: Detailed ISD (continuous diagnosis) diagnosis system that provides complete status images (not related to safety) Operating status indicator (green/red) Switching output indicator (yellow) IP69K SIL3 (IEC61508) PLE (ISO13849-1) Required for the operation of the Si-RF-A actuator |
- | - | - | - | - | High High μ |
Click on the part number for more information about each product