Product
LevelFlex FMP54 for liquid guide trader type continuous level meterHandling Company
Endress+Hauser Group Services AGCategories
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Application limit | Characteristics / application | Class certification | Design certification | Features | Interface measurement | Major liquid portion | Maximum measurement distance | Measurement principle | Power / communication | Process connection | Process pressure / maximum overpressure limit | Process temperature | Safety certification | Selection item | Sensor length | Standard conformity certificate/authentication | accuracy | communication |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LevelFlex FMP54 |
Available upon quote |
-50 ~+80 ° C (-58 ~+176 ° f) |
Application limit |
Premium device high -voltage/high temperature specification Rod probe, rope probe, coukenical probe Built -in data memory, proofreading before shipment, highly reliable measurement: Moving measurement surface + foam, also corresponding to changes in measurements |
GL/DNV/ABS/LR/BV |
EN 10204-3.1 Nace MR0175, MR0103 ASME B31.1, B31.3 AD2000 Boiler authentication |
HeartBeat Technology, Bluetooth® setting, Operation and maintenance by Smartblue app, Historom, Easy identification by RFID tag |
Interface/liquid that can be clearly recognized Same clock measurement of interface and level |
Rod probe: SUS304 equivalent, SUS316L equivalent, Aloy C, Ceramic Rope Prove: SUS304 equivalent, SUS316 equivalent, SUS316L equivalent, Aloy C, Ceramic Coukical Prove: SUS304 equivalent, SUS316L equivalent, Aloy C, Ceramic |
rod: 10m minimum DK> 1.6 rope: 25 m ... 30m minimum DK> 1.6; 30 m ... 45 m minimum DK> 1,9 Coukical Prove: 6 M Minimum DK> 1.4 |
Guide trader |
2 -wire type (HART/PROFIBUS PA/FOUNDATION field bus) 4 -wire type (HART) Bluetooth® wireless technologies and apps (options) |
screw: G 1 1/2, mnpt 1 1/2 Flange: ASME 2 "... 4", DN50 ... DN100, JIS 10k, 63k, Fisher Masoneilan |
Vacuum ~ 40 mpa (Vacuum ~ 5,800 PSI) |
XT: -196 ~+280 ° C (-321 ~+536 ° f) HT: -196 ~+450 ° C (-321 ~+842 ° f) |
Overflow prevention WHG SIL |
3 m/9 FT cable separate type sensor, Remote control by Smartblue app via Bluetooth® |
Rod probe: 10 m Rope Prove: 45 m Coukical Prove: 6 M |
ATEX, FM, CSA C/US, IEC EX, InMetro, Nepsi, KC, EAC, JPN EX, UK EX |
Rod probe: +/- 2 mm Rope probe <= 15 m: +/- 2 mm Rope Prove> 15 M: +/- 10 mm Coukical Prove: +/- 2 mm |
4 ~ 20 ma heat Profibus PA Foundation field bus Bluetooth® Wireless Technology |
Endress+Hauser Group Services AG