Inline type flow meter with up to 4 I/O with excellent long -term stability ■ Applications The T-Mass F patented sensor design provides unprecedented measurement stability in the heat-mass flow rate measurement of the inline type. Changes in process conditions in real time, such as temperature, pressure, flow direction, and gas type. T-MASS F 500, a separated innovative converter, guarantees the operation safety of the installation with very high flexibility and requirements. HeartBeat Technology guarantees the reliability and compatibility verification of measurement. ・ Measurement principles featuring direct measurement of wide flow rate and mass flow rate ・ Measurement of utility gas, process gas, and mixed gas in small -diameter piping ■ Features of equipment ・ Inline type corresponding to 15-100 mm (1/2-4 "). ・ Bid -like measurement, high measurement performance ・ Sensor without a patented drift that complies with SIL 2 ・ Separate type, with up to 4 I/O ・ Backlight display with touch control and WLAN connection ・ Standard cable between the sensor and the converter ■ Advantages ・ Easy programming with 21 types of standard gas or mixed gas that can be set arbitrarily ・ High -level process control -The best measurement accuracy and repetition ・ Highly reliable monitoring - detection of non -process disturbance and reflux ・ Easy maintenance - removable sensor ・ Full access to processes and diagnostic information -I/O and field buses that can be combined by various ・ Reduction of complexity and large combination -I/O functions that can be set arbitrarily ・ Built -in verification function - HeartBeat Technology ■ Product -Aline -type flow meter with up to four I/O, a separate type with excellent long -term stability. ・ Easy programming with 21 types of standard gas or mixed gas that can be set arbitrarily. ・ Measurement of utility gas, process gas, and mixed gas in small -diameter piping. ■ Features of sensor ・ High -level process control -best measurement accuracy and repeatability. ・ Reliable monitoring -Detection of process disorders and reflux. ・ Easy maintenance -a removable sensor. ・ Inline version, call caliber 15-100 mm (1/2-4 "). ・ Bid -like measurement, high measurement performance. A sensor without a patented drift that complies with SIL 2. ■ Features of converter ・ Full access to processes and diagnostic information -Various I/O and field bus can be combined arbitrarily. ・ Relieving complexity and diversity -an I/O function that can be set arbitrarily. ・ Built -in verification function - Heartbeat Technology. ・ Separate type, with up to four I/O. ・ A backlight display with a touch control and WLAN connection. ・ Standard cable between the sensor and the converter.

  • Product

    Flow rate that can be measured by liquid and gas flow rate Proline T-MASS F 500 Thermal mass flow rate meter

Share this product


230+ people viewing

Last viewed: 6 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Flow rate that can be measured by liquid and gas flow rate Proline T-MASS F 500 Thermal mass flow rate meter

Product Image Part Number Price (excluding tax) Call caliber range Certification and authentication regarding measurement Digital communication Display / operation Explosion -proof certification Functional safety Liquid part material Material certificate Material of converter housing Maximum measurement error Maximum process pressure Measured value Measurement principle Measurement range Peripheral temperature range Pressure certification and authentication Process temperature of measurements Product safety Protection grade input output power supply
Flow rate that can be measured by liquid and gas flow rate Proline T-MASS F 500 Thermal mass flow rate meter-Part Number-Proline T-MASS F 500

Proline T-MASS F 500

Available upon quote Call caliber: 15 ~ 100 mm (1/2 ~ 4 ") Calibration at certification facilities (compliant with ISO/IEC 17025)
HeartBeat Technology corresponds to ISO 9001: 2015 - Section 7.1.5.2 A compliant traceability requirements
HART, MODBUS RS485 4 lines display, display part with backlight, touch control (operated from outside)
Can be set from site display and operation tools
ATEX, CCSAUS, IECEX, NEPSI, JPN, UK EX, EAC Compatible with functional safety that complies with IEC 61508, functional safety applications compliant with IEC 61511 Measuring tube
・ Call caliber: 15 ~ 50 mm (1/2-2 "): Stainless steel casting, CF3M/1.4408
・ Call caliber: 65 ~ 100 mm (2½ ~ 4 "): Stainless steel, 1.4404 (SUS 316 or 316L equivalent)
Process connection
Flange connection
Stainless steel, 1.4404 (equivalent to SUS F316 or F316L)
Screw -in connection
Stainless steel, 1.4404 (SUS 316 or 316L equivalent)
Measurement element
One direction
・ Stainless steel, 1.4404 (SUS 316 or 316L equivalent)
・ Aloy C22, 2.4602 (UNS N06022);
Two -way
Stainless steel, 1.4404 (SUS 316 or 316L equivalent)
Backflow detection
Stainless steel, 1.4404 (SUS 316 or 316L equivalent)
3.1 Material certificate
Nace MR0175/MR0103
Aluminum, ALSI 10mg, coating
Polycarbonate
Gas: 1.0% O.R. (10-100% O.F.S.), 0.1% O.F.S. (1-10% O.F.S.) PN40 / CL. 300 / 20k Mass flow rate, temperature, standard volume flow, volume flow rate, free air protruding, flow speed, heat flow, energy flow, density Thermal style 0.5 ~ 3,750 kg/h (1.1 ~ 8,250 LB/h) -40 ~+60 ° C (-40 ~+140 ° f)
option:
Converter: -50 ~+60 ° C (-50 ~+140 ° f),
Sensor: -60 ~+60 ° C (-60 ~+140 ° f)
PED, CRN -40 ~+180 ° C (-40 ~+356 ° f) CE, C-Tick IP66/67, Type 4X container, sensor: IP68, Type 6P (optional) Status input
4 ~ 20 ma input
4 output:
4-20 MA Hot (Active/Passive)
4-20 MA (Active/Passive)
Pulse/frequency/switch output (active/passive)
Relay output
DC 24 V
AC 100 ~ 240 V

Customers who viewed this product also viewed

Other products of Endress+Hauser Group Services AG


View more products of Endress+Hauser Group Services AG

About Company Handling This Product

Endress+Hauser Group Services AG

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree