Product
Flow rate measurement of liquid flow rate Proline Promag W 300 Electromagnetic flow meterHandling Company
Endress+Hauser Group Services AGCategories
Product Image | Part Number | Price (excluding tax) | Call caliber range | Certification and authentication regarding measurement | Digital communication | Display / operation | Explosion -proof certification | Ferry class certification and authentication | Functional safety | Liquid part material | Material certificate | Material of converter housing | Materials of sensor housing | Maximum measurement error | Maximum process pressure | Measured value | Measurement principle | Measurement range | Peripheral temperature range | Pressure certification and authentication | Process temperature of measurements | Product safety | Sanitari certification and authentication | input | output | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Proline Promag W 300 |
Available upon quote | 25 ~ 3000 mm (1 ~ 120 ") |
Calendarized at the certified facility (compliant with ISO/IEC 17025), NAMUR HeartBeat Technology corresponds to measurement traceability requests conformed to ISO 9001: 2015 - Section 7.1.5.2 a (Tüv Süd certificate) |
HART, Profibus DP, Profibus PA, Foundation Field Bus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA |
4 lines display, display part with backlight, touch control (operated from outside) Can be set from site display and operation tools Separate display can be used |
ATEX, IECEX, CCSAUS, NEPSI, InMetro, UK EX | LR certification, DNV GL certification, ABS certification, BV certification | Compatible with functional safety that complies with IEC 61508, functional safety applications compliant with IEC 61511 |
Lining: Polyurethane; Hard rubber, PTFE Electrode: 1.4435 (equivalent to SUS 316L); Aloy C22, 2.4602 (UNS N06022); Tantal |
3.1 Material certificate | ALSI10mg, coating; 1.4409 (CF3M) (equivalent to SUS 316L); Stainless steel suitable for sanitari converter |
25 ~ 300 mm (1 ~ 12 "): ALSI10mg, coating 25 ~ 2400 mm (1 ~ 90 "): Carbon steel with protective painting Sensor connection housing (standard): ALSI10mg, coating Sensor connection housing (optional): Polycarbonate; 1.4409 (CF3M) (equivalent to SUS 316L) |
Volume flow rate (standard): ± 0.5 % O.R. 1 mm/s (0.04 in/s) A volume flow rate (option): ± 0.2 % O.R. ± 2 mm/s (0.08 in/s), flat specifications |
PN 40, Class 300, 20k | Volume flow rate, conductive rate, mass flow rate | Electromagnetic format | 0.5 m³/h ~ 263,000 m³/h (2.5gal/min ~ 1,665 mgal/d) |
Flange material: Carbon steel: --10 ~+60 ° C (+14 ~+140 ° f) Flange material: Stainless steel: --40 ~+60 ° C (–40 ~+140 ° f) |
CRN, PED |
Lining material: Hard rubber: 0 ~+80 ° C (+32 ~+176 ° f) Lining material: polyurethane: --20 ~+50 ° C (–4 ~+122 ° f) Lining material: PTFE: --20 ~+90 ° C (–4 ~+194 ° f) |
CE, C-Tick, EAC Marking | ACS, KTW/W270, NSF 61, WRAS BS 6920 |
Status input 4 ~ 20 ma input |
3 Output: 4-20 MA Hot (Active/Passive) 4-20 MA Wirelesshart 4-20 MA (Active/Passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
DC 24 V AC 100-230 V AC 100-230 V / DC 24 V (non -dangerous place) |
Endress+Hauser Group Services AG