Price (excluding tax)
■ Characteristics ・ SSCNET Ⅲ/H specification ・ Supported speed command operation, torque command operation, position control operation for sscnet Ⅲ/h, SSCNET II ■ mode ・ Communication mode ・ Maintenance mode The value of the item is for maintenance mode ■ Control input signal External input signal 4 points In the case of communication mode, the following signals can be assigned ・ ARST (alarm reset) ・ TL (torque limit) ・ Rot (opposite direction over travel) ・ MTOH (overheating motor) ・ EMG (emergency stop) ・ FOT (Over Travel) ・ ZLS (origin deceleration) When assigning an external input signal, signal logical switching is possible. The control input signal can be fixed in the signal ON/OFF state. ■ Control output signal External output signal 2 points In the case of communication mode, the following signals can be assigned ・ ALM (alarm) ・ RDY (servo lady) ・ PE1 ~ PE2 (position deviation range 1-2) ・ ZZ (command completed) ・ PRF (rough match) ・ BRK (brake release) ・ EMGO (in the emergency stop) ・ OTO (during over travel) ・ SMOD (in speed command mode) ・ PMOD (in position control mode) ・ OCEM (marker output) ・ WNG (warning) ・ SZ (zero speed) ・ PN1 ~ PN2 (positioning completed 1-2) ・ Zrdy (command launch lady) ・ VCP (reach speed) ・ LIM (restricted) ・ HCP (Completion of the origin of the origin) ・ MTON (being energized by motors) ・ TMOD (in torque command mode) ・ NMOD (in internal organs command mode) Signal logical switching is possible when assigned to an external output signal (excluding OCEM)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Acceleration deceleration and deceleration
Cutter command coordinate management
Drive system
Driving mode
Gutter command command
Gutter command diversion
Internal speed command
Internal torque command
Mounting method
Mutual command S -shaped deceleration
Organization command setting unit
Peripheral conditions temperature ℃
Plateau conditions Humidity use/when saving
Pulse command command form
Pulse command correction
Pulse specified S -shaped deceleration
Speed command acceleration deceleration
Speed command analog command (optional)
Speed control speed control range
Speed control speed fluctuation load characteristics
Speed control speed fluctuation rate characteristics
Speed control speed fluctuation rate voltage characteristics
Torque command analog command (optional)
Torque control decomposition ability
Torque control reproducibility
Torque increase time
Vibration resistance
Viper conditions elevation
When saving peripheral conditions
control method
Part Number
VPH-HBHandling Company
CKD Nisshin Electrical Corporation Co., Ltd.Items marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Acceleration deceleration and deceleration | Cutter command coordinate management | Drive system | Driving mode | Gutter command command | Gutter command diversion | Internal speed command | Internal torque command | Mounting method | Mutual command S -shaped deceleration | Organization command setting unit | Peripheral conditions temperature ℃ | Plateau conditions Humidity use/when saving | Speed command acceleration deceleration | Speed control speed control range | Speed control speed fluctuation load characteristics | Speed control speed fluctuation rate characteristics | Speed control speed fluctuation rate voltage characteristics | Torque control decomposition ability | Torque control reproducibility | Torque increase time | Vibration resistance | Viper conditions elevation | When saving peripheral conditions | control method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 8点 (0~99.999secの範囲で、加速と減速を個別で設定可能) | Infinite sending, absolute positioning-2147483648 ~+2147483647, load shaft 1 rotation position management (eg, 0 ~ 359DEG, -179 ~ 180deg) | 3 Sono Masamasa PWM | Speed command operation, torque command operation, visceral command operation | 256 points, 3 types POS (positioning): ABS/Inc, IndX (determined by the outpatient position): Awareness/one direction, HOME (return to the origin): STD, LS less, OT return, on the spot, OT Return LS less | Speed 8 points | 7 Select by control signal (set unit speed command) | 7 Select by control signal (set unit 0.1%) | Panel mounting | 8 points (0 to 1.000Sec) | pulse | 0 ~ 55 | 90%RH or less | Acceleration and deceleration are set individually within the 0 to 99.99999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999s | 1: 5,000 analog speed command 1: 2,000 | 0 to 100%load: ± 0.01%or less (at rated speed) | 0 to 40 ° C: ± 0.1%or less (at rated speed) ± 0.2%or less for analog directing | Rated voltage ± 10%: 0% (at rating speed) | 1: 1,000 (up to rated torque) | ± 1% (up to rated torque) | 0 to 9.9999sec | 5.9m/s*2 (10 ~ 55Hz) However, without resonance | 1,000m or less | 20 ~ 65 | Regular braking: Resurrection resistance external |
CKD Nisshin Electrical Corporation Co., Ltd.