Digital instruction ORP meter Aer-101-Orp-Shinko Technos Co., Ltd.

Aer-101-Orp, C5 | Digital instruction ORP meter Aer-101-Orp
Shinko Technos Co., Ltd.


Price (excluding tax)

Estimate Required


Model Description

・ Input number: 1 point ・ Input: ORP composite electrode sensor ・ Power supply voltage: 100-240 V AC (standard) ・ Options: Serial communication RS-485


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Ambient temperature

Conformity standard

Contact output

External dimensions

Input sampling cycle

Linearness

Measurement range

Moving average number

Peripheral humidity

Protective structure

Repetition

Self -diagnostic function

Serial Communication (Options: C5) Data Bit/Parity

Serial communication (Options: C5)

Serial communication (Options: C5) Certification format

Serial communication (Options: C5) Communication method

Serial communication (Options: C5) Communication protocol

Serial communication (Options: C5) Communication speed

Serial communication (Options: C5) Stop bit

Serial communication (Options: C5) Sync

Serial communication (Options: C5) error correction

Serial communication (option: C5) cable length

Serial communication (option: C5) communication line

Serial communication (option: C5) error detection

Time accuracy

Transmission output 1

Transmission output 2

mass

power supply

structure

See all 4 models in list
  • Part Number

    Aer-101-Orp, C5




*Please note that we may not be able to accommodate sample requests.

Digital instruction ORP meter Aer-101-Orp Aer-101-Orp, C5's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Ambient temperature Conformity standard Contact output External dimensions Input sampling cycle Linearness Measurement range Moving average number Peripheral humidity Protective structure Repetition Self -diagnostic function Serial Communication (Options: C5) Data Bit/Parity Serial communication (Options: C5) Serial communication (Options: C5) Certification format Serial communication (Options: C5) Communication method Serial communication (Options: C5) Communication protocol Serial communication (Options: C5) Communication speed Serial communication (Options: C5) Stop bit Serial communication (Options: C5) Sync Serial communication (Options: C5) error correction Serial communication (option: C5) cable length Serial communication (option: C5) communication line Serial communication (option: C5) error detection Time accuracy Transmission output 1 Transmission output 2 mass power supply structure
Digital instruction ORP meter Aer-101-Orp-Part Number-Aer-101-Orp, C5 Available upon quote 0 to 50 ℃ ROHS command support ・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation W48XH96XD110mm case depth: 98.5mm (at panel mount) 125ms Within ± 5 MV (for equivalent input) -2000 ~ 2000 MV, decomposition ability: 1 MV 1 to 120 times 35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) Within ± 5 MV (for equivalent input) Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Perform the following operations from the external computer. ・ Read and set various set values ・ Read of ORP value and state ・ Change and adjust function ・ Reading and setting of user storage area ASCII, binary Half double communication Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation Select 9600, 19200, 38400 BPS by key operation Select 1 bit and 2 bits by key operation Toning synchronization Command resend 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant ・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) Within ± 1%for the set time ORP value or MV is converted to analog amount for each input sampling and output by current. If the transmission output maximum value and the lower limit of the transmission output are set to the same value, the transmission output is fixed to 4 ma DC. ・ The transmission output volume can be displayed. ・ Resolution: 12,000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output span Approximately 280g 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66

There are 4 models for this product.

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree