Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Angle Decomposition Ability
Angle decomposition ability
Current Consumption Current
Current consumption current
Division and Detector
Division and detector
Hysterical
Impact Resistance
Impact resistance
Indicator light
Light Source
Peripheral term
Power-Supply Voltage
Power-supply voltage
Protective Structure
Protective structure
Repetition
Response Time
Response time
START-UP TIME
Scanning Angle
Scanning angle
Start-up time
Synchronous function
Time of Scanning
Time of scanning
USed Peripheral Temperature Humidity
Used peripheral temperature humidity
Vibration Resistance
Vibration resistance
input
interface
kinds
light source
mass
output
Part Number
UST-05LAHandling Company
Hokuyo ElectricItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Angle Decomposition Ability | Angle decomposition ability | Current Consumption Current | Current consumption current | Division and Detector | Division and detector | Hysterical | Impact Resistance | Impact resistance | Indicator light | Light Source | Peripheral term | Power-Supply Voltage | Power-supply voltage | Protective Structure | Protective structure | Repetition | Response Time | Response time | START-UP TIME | Scanning Angle | Scanning angle | Start-up time | Synchronous function | Time of Scanning | Time of scanning | USed Peripheral Temperature Humidity | Used peripheral temperature humidity | Vibration Resistance | Vibration resistance | input | interface | kinds | light source | mass | output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 0.5 DEGREES | 0.5 degrees | 150ma or More, However, a Rush Current is Required at about 400ma. | 150mA or more, however, a rush current is required at about 400mA. | 60mm to 5000mm60mm ~ 2000mm minimum Detector 130mm | 60mm to 5000mm60mm ~ 2000mm minimum detector 130mm | HYSTERESIS 6.25%HYSTERESIS 3.125%NO HYSTERESIS | 196 M/S2X. Y. Z Direction 10 Times Each | 196 M/S2X. Y. Z direction 10 times each | Power Supply Lantern: Lighting, Output Output 1 Indicator at Startup, and Failure: LightPut in The Area Detection 2 L IGHTING OUTPUT IN THE AREA Detection 3 Display Lights: Lights in the Area. | SEMICONDUCTOR LASER LASER SAFETY CLASS 1 | 80,000LX or less) note) If you receive strong as Such as sunlight Directly, you may be erroneous. | Power Supply Voltage DC12V/DC24V | Power supply voltage DC12V/DC24V | IP65 | IP65 | σ <20mm | OFF: 66msec ~ 3241msecon: 66msec ~ 3241msec | OFF: 66msec ~ 3241msecon: 66msec ~ 3241msec | Within 10sec | 270 DEGREES | 270 degrees | Within 10sec | Synchronous Operation Mode Synchronous Slave Synchronous Slave Synchronous Slave Synchronous Slave | 25msec | 25msec | -10 ℃ ~+50 ℃ 85%RH or Less | -10 ℃ ~+50 ℃ 85%RH or less | 10-55HZ DOUBLE WIDTH 1.5 m Mx. Y. Z Direction 2 HOURS 55-20HZ98 M/S2 Super 2 Minutes X. 1 Hour Each | 10-55Hz double width 1.5 m mx. Y. Z direction 2 hours 55-20HZ98 M/S2 Super 2 minutes X. Y. 1 hour each | Input 6 Points Input 1-5: Input Area Switching Synchronous Input: Synchronous Signal Input of Slave Machine | USBRS422 | Detection Area Setting Type | Semiconductor laser laser safety class 1 | 130g | Output 5 -Point Output 1: Output Off Output 2: Output Off Output By Detection In The Area 3: Output Off Off Off 4: Failure Output Output 4: Failur e output output 5: if the output of sync output is output, it will indicate 1 to 3 ObstacleS. |