Product
Peltier temperature controller (TEC controller / Peltier for TEC controller / Peltier) Pelchakontroller PLC seriesHandling Company
Joint company clug electronItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Compatible temperature sensor | Current current consumption (body) | Current current consumption (indicator) | Main temperature sensor | Operation temperature humidity range | Peltier drive output current | Peltier drive system | Peltier driven output voltage | Power-supply voltage | Saving temperature humidity range | Setting / display resolution ability | Setting temperature range | Sub temperature sensor | Timer setting range | control method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PLC-24v6a / PLC-5v6a |
$ 108.80〜 | Shirokane Temperature resistance (PT) or NTC Thermista 3 conductor/2 conductor type PT sensor compatible ∗ Specify the sensor type when receiving orders. | 170mA (MAX) Peltier element drive current and DC fan drive current are not included | 90mA (MAX) | Shirokane Temperature resistant (PT) or NTC Thermista 3 conductor/2 conductor compatible ∗ Specify the sensor type when ordering | 10 ° C to 40 ° C/5%to 85%without condensation | 6a (MAX) Maximum output current is restricted by power supply voltage and internal resistance of Peltier elements and electromotive force | PWM voltage drive cooling/Heated both directions | PLC-24v6a: 24V (MAX) PLC-5v6a: 5V Output voltage is restricted by power supply voltage | PLC-24v6a: DC7V-24vPLC-5V6A: DC5V ± 0.25V | -20 ° C to 60 ℃/5%to 90%without condensation | 0.1 ° C custom products may have different resolution. | -20.0 ° C ~+100.0 ° C (Pt) -10.0 ° C ~+80.0 ° C (NTC) Custom products may have different temperature ranges. | - | 0.1 minutes to 999.9 minutes 0.1 hours to 720 hours set or hourly set time accuracy ± 1% | Digital PI control sensor output is converted to A/D and digital processing | |
PLC-24v10AL-PT (PT100) / PLC-24v10al-TH (NTC Thermista) |
$ 185.60〜 | - | 150mA (MAX) Peltier element drive current and DC fan drive current are not included | 90mA (MAX) | PLC-24v10AL-PT Shirokane Mass-Temperature resistant (PT100) ∗ 3 conductor/2 Conducted PT sensor compatible PLC-24v10al-Thntc Thermista (R25 = 10kΩ) ∗ You can select NTC Thumista varieties by dedicated configuration software. | 10 ° C to 40 ° C/5%to 85%without condensation | 10A (MAX) drive current is restricted by power supply voltage, internal resistance and thermal power of Pelte elements | PWM voltage drive cooling/Heated both directions | 7V to 24V (single power supply operation) Depending on the power supply voltage 0.5V to 24V (2 power operations) Depending on the power supply voltage | DC7V ~ 24V single power supply When operating Peltier driving (VP): DC0.5V to 24v2 Power operation for control circuits (F+): DC7V -24v2 Power supply | -20 ° C to 60 ℃/5%to 90%without condensation | 0.1 ℃ | -40 ℃ ~+100 ° C ∗ You can change the set temperature range by dedicated setting software | You can select sensor varieties by dedicated configuration software (R25 = 10kΩ) ∗ | 0.1 minutes to 999.9 minutes 0.1 hours to 720 hours set or hourly set time accuracy ± 1% | You can change the PID control parameters by digital PID control ∗ dedicated setting software | |
PLC-24v10A |
$ 236.80〜 | - | 150mA (MAX) Peltier element drive current and DC fan drive current are not included | 90mA (MAX) | Shirokane measurement temperature resistor (PT100) NTC thumista (R25 = 10kΩ) 3 conductor/2 leading PT sensor compatible ∗ You can select sensor varieties by dedicated configuration software | 10 ° C to 40 ° C/5%to 85%without condensation | 10A (MAX) drive current is restricted by power supply voltage, internal resistance and thermal power of Pelte elements | PWM voltage drive cooling/Heated both directions | 3V to 24V (single power supply operation) Depending on the power supply voltage 0.5V to 24V (2 power operations) Depending on the power supply voltage | DC3V ~ 24V single power supply operation for Peltier driving (VP): DC0.5V to 24v2 For control circuits (F+): DC3V -24v2 Power supply | -20 ° C to 60 ℃/5%to 90%without condensation | 0.1 ℃ | -50 ℃ ~+150 ° C (PT100) -40 ° C ~+100 ° C (thermista) ∗ You can change the set temperature range by dedicated setting software. | You can select sensor varieties by dedicated configuration software (R25 = 10kΩ) ∗ | 0.1 minutes to 999.9 minutes 0.1 hours to 720 hours set or hourly set time accuracy ± 1% | You can change the PID control parameters by digital PID control ∗ dedicated setting software |
Click on the part number for more information about each product