High speed strain gauge panel meter VGM4 seriesHandling Company
VALCOM CO.,LTD.Categories
Product Image | Part Number | Price (excluding tax) | A/D conversion speed | AC adapter power specifications | Bridge voltage | Calibration accuracy | Calibration range | Calibration settings | Compatible standards | D/A output | DC power specifications | Decimal point | Digital filter | Display | Display range | External dimensions | External input signal CC-Link | External input signal input | External input signal output | Function settings | Gain drift | Hold function | Mass | Nonlinearity | Number of views | Operating humidity range | Operating temperature range | Signal input range | Storage temperature range | TEDS function | Zero drift | Zero point adjustment range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VGM4 |
Available upon quote | 4,000 times/second | DC12V 9W, AC100~240V 50/60Hz 12W (includes attached AC adapter) | DC10V, 2.5V±10% (current maximum 30mA, remote sensing available) | Within 0.1%F.S. (φ8-4 core shielded cable, length 1m, load resistance 350Ω, BV10V, 0.5mV/V or more) | 0.3~3.2mV/V | Zero calibration/span calibration (TEDS calibration, actual load calibration, equivalent input calibration) | CE marking - EN62326 (Class A), UL61010-1 | Isolated output Voltage output 0~±10V (settable in 1V steps) or current output 4~20mA | Rated DC12V-24V 9W (not available when special case is selected) | Display position can be selected | Select from 3Hz (-6db/oct) 10, 30, 100, 300, 1000Hz (-12db/oct), None | 320×240 color LCD | -99,999~99,999 | Approximately 96 (W) × 53 (H) × 131 (D) mm (excluding protrusions) | CC-Link Ver.1.10 Remote device station Maximum number of connections: 42, DA, DB (isolated from main circuit with photocoupler), DG, SLD | Hold, judgment, clear, digital zero, set value memory selection 1, set value memory selection 2 (isolated from the main unit circuit with a photocoupler) | HH, HI, OK, LO, LL open collector output (isolated from main circuit with photocoupler) | Upper limit, lower limit, upper upper limit, lower lower limit, comparison mode, hysteresis, near zero, moving average processing, low pass filter, motion detection, zero tracking, static strain, digital zero, digital tare subtraction, section specification | Within ±0.005%F.S./℃ |
Sample hold, peak hold, bottom hold, peak to peak hold, peak and bottom hold, Average hold, section specified hold (peak, bottom peak to peak) |
Approximately 300g | Within 0.01%F.S. + 1Digit (when input is 1mV/V or more) | Select from 4, 6, 10, 20 times/sec | 85%RH or less (no condensation) | 0~40℃ | ±3.2mV/V | -20~60℃ | IEEE1451.4 Class 2 mixed mode interface, cannot be used with applied voltage remote sense function | Within 0.5μV/℃ (input equivalent value) | ±2mV/V |