High speed strain gauge panel meter VGM series-VGM-2SO-A3-1
High speed strain gauge panel meter VGM series-VALCOM CO.,LTD.

High speed strain gauge panel meter VGM series
VALCOM CO.,LTD.


About This Product

Equipped with SPC function enables 4-point monitoring during pressurization process. Ideal for press-fitting, caulking, and molding applications ■Features ・Accuracy of pass/fail judgment is dramatically improved by measuring at four arbitrary points during the pressurization process ・Low cost compared to pressure waveform image data comparison measuring instruments - Initial peak removal function allows comparative measurements without counting irregular peaks when contacting the workpiece. ・3 types available: analog 4-20mA, 0-10V and BCD output ・Peak hold function: "A type" that always displays the peak and "B type" that displays the peak for each shot can be selected. ・Digital zero function, function to measure the value displayed immediately before as "zero" ・Tracking zero function, function that automatically corrects the movement of the zero point internally digitally ・Pattern selection function, it is possible to set up to 4 comparison patterns ■Initial peak removal function There is an initial peak removal function that excludes sudden inputs when contacting a workpiece from counting. By using this function, you can perform comparisons while ignoring unnecessary initial peak values ​​as comparison conditions. This function is also useful when the effective maximum load value is less than the initial peak value, such as when the maximum load value is always displayed. The time interval for removing the initial peak ([T] interval in the figure) can be set freely, so you can perform comparative measurements that fit your system. ■Peak hold function Peak hold function that displays the peak of the load value. There are type A, which always displays the peak, and type B, which displays the peak for each shot. Peak hold A type is a free run type. The peak value will continue to be held until the PH terminal signal is open or reaches the "1" level. Peak hold B type is a type of peak hold that displays the maximum load value for each shot. The peak value continues to be held while the PH terminal signal is open or at "1" level. However, the display does not follow and is updated every time the PH terminal falls. ■Digital zero function This function measures the value displayed immediately before as "zero." The subsequent display will look like this: (input value - digital zero value) = display value

  • Product

    High speed strain gauge panel meter VGM series

Share this product


190+ people viewing

Last viewed: 9 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

3 Models of High speed strain gauge panel meter VGM series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy Comparison condition Upper limit setting value ≧ Measured value ≧ Lower limit setting value Comparison conditions Lower limit set value > measured value Comparison conditions Measured value > Upper limit setting value Comparison operation Compatible sensor Control method Decimal point Digital zero Display Gain adjustment range Hold Hysteresis Maximum display Maximum input voltage Minimum input sensitivity Monitor display Operation method Overrange warning Pattern selection Peak, Valley, Peak Valley Hold Photocoupler output (NPN type) Polarity display Sampling rate Sensor power supply Setting range Start Temperature characteristics Zero display Zero point adjustment range
High speed strain gauge panel meter VGM series-Part Number-VGM-2SO-A3-1

VGM-2SO-A3-1

Available upon quote ± (0.15% of F.S. +1digit) (23℃±5℃), ± (0.05% of F.S. +1digit) (23℃±5℃, sampling speed = 20・10・5・2・1 times/sec) GO L.O. HI Single point comparison using comparison numbers C1 to C4 or normal comparison using comparison number C1 Various strain gauge type sensors (350Ω) Microcomputer calculation method Can be set to any position (switching is done using the key switch on the front) If the COM terminal and DZ terminal are shorted or at the "0" level, the previous displayed value will be displayed as "zero" and that value will be stored. 7 segment LED character height 14.2mm (red), comparison setting display character height 8mm (green) 0.001~+3.300mV/V COM terminal and S/H terminal shorted or "0" level Can be set from 1 to 999 digits for each comparison setting value (comparison number C1 only) 9,999 3.3mV/V 0.5μV/digit Peak hold (PH), digital zero (DZ), digital zero backup (ME) Successive approximation method o.L." or "-o.L." is displayed for input signals exceeding the measurement range 4 patterns can be set arbitrarily by combining COM terminal and P.SEL terminal 0,1 COM terminal and PH terminal shorted, "0" level, peak hold type depends on each comparison C1 to C4 settings (switching is done using the key switch on the front) Maximum allowable load: 30V 20mA Output saturation voltage 1.2V or less at 20mA Display "-" when the calculation result is negative 2,000 times/second DC5V±10% 60mA Upper and lower limit settings including polarity -9,999~0~9,999 COM terminal and S/H terminal open or "1" level ± (0.005% of rdg +0.5digit) /℃ Leading zero suppress -1.000~+1.000mV/V
High speed strain gauge panel meter VGM series-Part Number-VGM-2SO-A5-1

VGM-2SO-A5-1

Available upon quote ± (0.15% of F.S. +1digit) (23℃±5℃), ± (0.05% of F.S. +1digit) (23℃±5℃, sampling speed = 20・10・5・2・1 times/sec) GO L.O. HI Single point comparison using comparison numbers C1 to C4 or normal comparison using comparison number C1 Various strain gauge type sensors (350Ω) Microcomputer calculation method Can be set to any position (switching is done using the key switch on the front) If the COM terminal and DZ terminal are shorted or at the "0" level, the previous displayed value will be displayed as "zero" and that value will be stored. 7 segment LED character height 14.2mm (red), comparison setting display character height 8mm (green) 0.001~+3.300mV/V COM terminal and S/H terminal shorted or "0" level Can be set from 1 to 999 digits for each comparison setting value (comparison number C1 only) 9,999 3.3mV/V 0.5μV/digit Peak hold (PH), digital zero (DZ), digital zero backup (ME) Successive approximation method o.L." or "-o.L." is displayed for input signals exceeding the measurement range 4 patterns can be set arbitrarily by combining COM terminal and P.SEL terminal 0,1 COM terminal and PH terminal shorted, "0" level, peak hold type depends on each comparison C1 to C4 settings (switching is done using the key switch on the front) Maximum allowable load: 30V 20mA Output saturation voltage 1.2V or less at 20mA Display "-" when the calculation result is negative 2,000 times/second DC5V±10% 60mA Upper and lower limit settings including polarity -9,999~0~9,999 COM terminal and S/H terminal open or "1" level ± (0.005% of rdg +0.5digit) /℃ Leading zero suppress -1.000~+1.000mV/V
High speed strain gauge panel meter VGM series-Part Number-VGM-2SO-B4-1

VGM-2SO-B4-1

Available upon quote ± (0.15% of F.S. +1digit) (23℃±5℃), ± (0.05% of F.S. +1digit) (23℃±5℃, sampling speed = 20・10・5・2・1 times/sec) GO L.O. HI Single point comparison using comparison numbers C1 to C4 or normal comparison using comparison number C1 Various strain gauge type sensors (350Ω) Microcomputer calculation method Can be set to any position (switching is done using the key switch on the front) If the COM terminal and DZ terminal are shorted or at the "0" level, the previous displayed value will be displayed as "zero" and that value will be stored. 7 segment LED character height 14.2mm (red), comparison setting display character height 8mm (green) 0.001~+3.300mV/V COM terminal and S/H terminal shorted or "0" level Can be set from 1 to 999 digits for each comparison setting value (comparison number C1 only) 9,999 3.3mV/V 0.5μV/digit Peak hold (PH), digital zero (DZ), digital zero backup (ME) Successive approximation method o.L." or "-o.L." is displayed for input signals exceeding the measurement range 4 patterns can be set arbitrarily by combining COM terminal and P.SEL terminal 0,1 COM terminal and PH terminal shorted, "0" level, peak hold type depends on each comparison C1 to C4 settings (switching is done using the key switch on the front) Maximum allowable load: 30V 20mA Output saturation voltage 1.2V or less at 20mA Display "-" when the calculation result is negative 2,000 times/second DC5V±10% 60mA Upper and lower limit settings including polarity -9,999~0~9,999 COM terminal and S/H terminal open or "1" level ± (0.005% of rdg +0.5digit) /℃ Leading zero suppress -1.000~+1.000mV/V

Click on the part number for more information about each product