Product Image | Part Number | Price (excluding tax) | Accuracy (23±5℃ 35~85%RH) | Case material | Compliant EN standard | Conversion method | Display resolution | Display section | Display update speed | External control | External dimensions | Input impedance | Input signal | Installation location | Insulation resistance | Mass | Maximum allowable input | Measurement channel | Measuring range | Operating temperature and humidity range | Over warning | Pollution degree | Power consumption | Power supply | Protective structure | Rated altitude | Sampling rate | Storage temperature and humidity range | Transient overvoltage | Vibration resistance | Withstand voltage | Zero display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VGM5-1 |
Available upon quote | ± (0.05% of FS+1digit) | Polycarbonate (PC) Black UL94V-0 | EN61326-1 (EMS: Industrial installation/EMI: Class A) "Applicable for wiring lengths of 30 m or less", EN61010-1, EN50581 | ΔΣ conversion method | 1/99,999 | 2.4 inch TFT LCD display, 1 channel input: Ach. measurement result, 2 channel input: Ach. measurement result, Bch. measurement result, calculation result, Ach. and Bch. measurement result | 10 times/second, 1 time/second | Assign any of the following 5 functions to the control terminal (user setting) ① Comparison output reset function: Comparison reset ② Current value hold function: Current value hold A/B/A&B ③ Maximum value hold function: Maximum value hold A/B/A&B | 96mm (W) ×52mm (H) ×145mm (D) | Approximately 1MΩ (±5V, 0~5V, 1~5V, ±10V, 0~10V), approximately 10Ω (±20mA, 0~20mA, 4~20mA) | Single ended | Indoor | DC500V 100MΩ or more | Approximately 350g | ±100V (±5V, 0~5V, 1~5V, ±10V, 0~10V), ±50mA (±20mA, 0~20mA, 4~20mA) | 1 channel or 2 channels (depending on model) | ±5V, 0~5V, 1~5V, ±10V, 0~10V, ±20mA, 0~20mA, 4~20mA | −5~50℃, 35~85%RH (non-condensing) | If the display range is exceeded, OVER or -OVER is displayed. | 2 | AC power supply 7: AC100V: 11VA max AC240V: 15VA max, DC power supply 5: DC12V: 6.5W max, DC power supply 8: DC24V: 6.5W max, DC48V: 7W max | AC power supply 7: AC100~240V±10% 50/60Hz, DC power supply 5: DC12V±10%, DC power supply 8: DC24~48V±10% | IP66 (front) | 2,000m or less | 1ch input product: max. 4,000 times/sec, 2ch input product: max. 2,000 times/sec | −10~70℃ 60%RH or less | II | 10~55Hz half amplitude 0.15mm X, Y, Z directions 30 minutes | AC power supply 7: Power supply terminal — Input/external control/comparison output/between various output terminals 3000 VAC for 1 minute, DC power supply 5 or 8: Power terminal — Input/external control/comparison output/between various output terminals 1500 VAC for 1 minute | Leading zero suppress | |
VGM5-3 |
Available upon quote | ± (0.05% of FS+1digit) | Polycarbonate (PC) Black UL94V-0 | EN61326-1 (EMS: Industrial installation/EMI: Class A) "Applicable for wiring lengths of 30 m or less", EN61010-1, EN50581 | ΔΣ conversion method | 1/99,999 | 2.4 inch TFT LCD display, 1 channel input: Ach. measurement result, 2 channel input: Ach. measurement result, Bch. measurement result, calculation result, Ach. and Bch. measurement result | 10 times/second, 1 time/second | Assign any of the following 5 functions to the control terminal (user setting) ① Comparison output reset function: Comparison reset ② Current value hold function: Current value hold A/B/A&B ③ Maximum value hold function: Maximum value hold A/B/A&B | 96mm (W) ×52mm (H) ×145mm (D) | Approximately 1MΩ (±5V, 0~5V, 1~5V, ±10V, 0~10V), approximately 10Ω (±20mA, 0~20mA, 4~20mA) | Single ended | Indoor | DC500V 100MΩ or more | Approximately 350g | ±100V (±5V, 0~5V, 1~5V, ±10V, 0~10V), ±50mA (±20mA, 0~20mA, 4~20mA) | 1 channel or 2 channels (depending on model) | ±5V, 0~5V, 1~5V, ±10V, 0~10V, ±20mA, 0~20mA, 4~20mA | −5~50℃, 35~85%RH (non-condensing) | If the display range is exceeded, OVER or -OVER is displayed. | 2 | AC power supply 7: AC100V: 11VA max AC240V: 15VA max, DC power supply 5: DC12V: 6.5W max, DC power supply 8: DC24V: 6.5W max, DC48V: 7W max | AC power supply 7: AC100~240V±10% 50/60Hz, DC power supply 5: DC12V±10%, DC power supply 8: DC24~48V±10% | IP66 (front) | 2,000m or less | 1ch input product: max. 4,000 times/sec, 2ch input product: max. 2,000 times/sec | −10~70℃ 60%RH or less | II | 10~55Hz half amplitude 0.15mm X, Y, Z directions 30 minutes | AC power supply 7: Power supply terminal — Input/external control/comparison output/between various output terminals 3000 VAC for 1 minute, DC power supply 5 or 8: Power terminal — Input/external control/comparison output/between various output terminals 1500 VAC for 1 minute | Leading zero suppress |
Click on the part number for more information about each product