Product Image | Part Number | Price (excluding tax) | Analog current output | Bearing pressure | Display range | Distribution diameter | Electric shock protection class | Humidity | Low -flow cut -off (LFC) | Mass (stainless steel type) | Mass (steel type) | Maximum current load | Maximum load resistance | Media | Media temperature | Model number | Number of signals | Operating temperature | Operating voltage | Output signal | Piping length | Protection grade | Pulse voltage | Reproducibility | Short circuit protection | Storage temperature | Temperature coefficient | Temperature monitoring accuracy | power consumption | pulse width |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Testo 6457 DN65 (2½ ") |
Available upon quote | 4-20 ma | 16 BAR (> DN200 14 BAR) | 0 to 120 % of full scale values | DN65 (2½ ") | III | <90 % | Can be changed by users. Settings at the time of factory: 0.13 %x full scale value | 11.1 kg | 9.2 kg | <150 ma | 500 Ω | Compressed air | -10 ~+60 ° C /+14 ~+140 ° f | 0555 6457 | 2 | 0 to +60 ° C | 18-30 VDC (EN 50178 SELV / Pelv) | Analog current output x 1, pulse output x 1 | 124 mm | IP 65: IP 67 | VDC / 2 V | ± (1.5 % x measurement value) | ◯ | -20 to +85 ° C C | ± (measured value x 0.07 %) 1/k | ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) | <80 ma | 0.002-2s (depending on the pulse output value) | |
Testo 6457 DN80 (3 ") |
Available upon quote | 4-20 ma | 16 BAR (> DN200 14 BAR) | 0 to 120 % of full scale values | DN80 (3 ") | III | <90 % | Can be changed by users. Settings at the time of factory: 0.13 %x full scale value | 13.2 kg | 11.3 kg | <150 ma | 500 Ω | Compressed air | -10 ~+60 ° C /+14 ~+140 ° f | 0555 6457 | 2 | 0 to +60 ° C | 18-30 VDC (EN 50178 SELV / Pelv) | Analog current output x 1, pulse output x 1 | 160 mm | IP 65: IP 67 | VDC / 2 V | ± (1.5 % x measurement value) | ◯ | -20 to +85 ° C C | ± (measured value x 0.07 %) 1/k | ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) | <80 ma | 0.002-2s (depending on the pulse output value) | |
Testo 6457 DN100 (4 ") |
Available upon quote | 4-20 ma | 16 BAR (> DN200 14 BAR) | 0 to 120 % of full scale values | DN100 (4 ") | III | <90 % | Can be changed by users. Settings at the time of factory: 0.13 %x full scale value | 15.4 kg | 13.5 kg | <150 ma | 500 Ω | Compressed air | -10 ~+60 ° C /+14 ~+140 ° f | 0555 6457 | 2 | 0 to +60 ° C | 18-30 VDC (EN 50178 SELV / Pelv) | Analog current output x 1, pulse output x 1 | 160 mm | IP 65: IP 67 | VDC / 2 V | ± (1.5 % x measurement value) | ◯ | -20 to +85 ° C C | ± (measured value x 0.07 %) 1/k | ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) | <80 ma | 0.002-2s (depending on the pulse output value) | |
Testo 6457 DN125 (5 ") |
Available upon quote | 4-20 ma | 16 BAR (> DN200 14 BAR) | 0 to 120 % of full scale values | DN125 (5 ") | III | <90 % | Can be changed by users. Settings at the time of factory: 0.13 %x full scale value | 23.2 kg | 21.3 kg | <150 ma | 500 Ω | Compressed air | -10 ~+60 ° C /+14 ~+140 ° f | 0555 6457 | 2 | 0 to +60 ° C | 18-30 VDC (EN 50178 SELV / Pelv) | Analog current output x 1, pulse output x 1 | 172 mm | IP 65: IP 67 | VDC / 2 V | ± (1.5 % x measurement value) | ◯ | -20 to +85 ° C C | ± (measured value x 0.07 %) 1 / k | ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) | <80 ma | 0.002-2s (depending on the pulse output value) | |
Testo 6457 DN150 (6 ") |
Available upon quote | 4-20 ma | 16 BAR (> DN200 14 BAR) | 0 to 120 % of full scale values | DN150 (6 ") | III | <90 % | Can be changed by users. Settings at the time of factory: 0.13 %x full scale value | 28.8 kg | 26.9 kg | <150 ma | 500 Ω | Compressed air | -10 ~+60 ° C /+14 ~+140 ° f | 0555 6457 | 2 | 0 to +60 ° C | 18-30 VDC (EN 50178 SELV / Pelv) | Analog current output x 1, pulse output x 1 | 180 mm | IP 65: IP 67 | VDC / 2 V | ± (1.5 % x measurement value) | ◯ | -20 to +85 ° C C | ± (measured value x 0.07 %) 1/k | ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) | <80 ma | 0.002-2s (depending on the pulse output value) | |
Testo 6457 DN200 (8 ") |
Available upon quote | 4-20 ma | 16 BAR (> DN200 14 BAR) | 0 to 120 % of full scale values | DN200 (8 ") | III | <90 % | Can be changed by users. Settings at the time of factory: 0.13 %x full scale value | 39.2 kg | 37.3 kg | <150 ma | 500 Ω | Compressed air | -10 ~+60 ° C /+14 ~+140 ° f | 0555 6457 | 2 | 0 to +60 ° C | 18-30 VDC (EN 50178 SELV / Pelv) | Analog current output x 1, pulse output x 1 | 180 mm | IP 65: IP 67 | VDC / 2 V | ± (1.5 % x measurement value) | ◯ | -20 to +85 ° C C | ± (measured value x 0.07 %) 1/k | ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) | <80 ma | 0.002-2s (depending on the pulse output value) | |
Testo 6457 DN250 (10 ") |
Available upon quote | 4-20 ma | 16 BAR (> DN200 14 BAR) | 0 to 120 % of full scale values | DN250 (10 ") | III | <90 % | Can be changed by users. Settings at the time of factory: 0.13 %x full scale value | 57.7 kg | 55.8 kg | <150 ma | 500 Ω | Compressed air | -10 ~+60 ° C /+14 ~+140 ° f | 0555 6457 | 2 | 0 to +60 ° C | 18-30 VDC (EN 50178 SELV / Pelv) | Analog current output x 1, pulse output x 1 | 196 mm | IP 65: IP 67 | VDC / 2 V | ± (1.5 % x measurement value) | ◯ | -20 to +85 ° C C | ± (measured value x 0.07 %) 1/k | ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) | <80 ma | 0.002-2s (depending on the pulse output value) |
Click on the part number for more information about each product