Thermal gas flow meter DN65-250 testo 6456-Testo 6456 DN65 (2½ ")
Thermal gas flow meter DN65-250 testo 6456-Testo SE & Co. KGaA

Thermal gas flow meter DN65-250 testo 6456
Testo SE & Co. KGaA


About This Product

Accurate compressed air consumption measurement with compressed air system, You can monitor consumption and leaks and perform flow rate measurements.

  • Product

    Thermal gas flow meter DN65-250 testo 6456

Share this product


450+ people viewing

Last viewed: 2 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

7 Models of Thermal gas flow meter DN65-250 testo 6456

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Analog current output Bearing pressure Display range Distribution diameter Electric shock protection class Humidity Low -flow cut -off (LFC) Mass (zinc plating steel / stainless steel) Maximum current load Maximum load resistance Measurement accuracy (applied to the measurement range) Media Media temperature Model number Number of output signals Operating temperature Operating voltage Piping length Protection grade Pulse voltage Reproducibility Short circuit protection Storage temperature Temperature coefficient accuracy power consumption pulse width
Thermal gas flow meter DN65-250 testo 6456-Part Number-Testo 6456 DN65 (2½ ")

Testo 6456 DN65 (2½ ")

Available upon quote 4-20 ma 16 BAR (> DN200 14 BAR) 0 to 120 % of full scale values DN65 (2½ ") III <90 % Can be changed by users. Settings at the time of factory: 0.13 %x final values ​​in the measurement range 8.5 kg <150 ma 500 Ω When compressed air purifying class 1 (particles) / 5 (humidity and moisture) / 1 (oil): ± (3 %x measured+ 0.3 %x final value of measurement range) Compressed air -10 ~+60 ° C /+14 ~+140 ° f 0555 6456 2 0 to +60 ° C 18-30 VDC (EN 50178 SELV / Pelv) 124 mm IP 65: IP 67 VDC / 2 V ± (1.5 % x measurement value) -20 to +85 ° C C ± (measured value x 0.07 %) 1/k ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) <80 ma 0.002-2s (depending on the pulse output value)
Thermal gas flow meter DN65-250 testo 6456-Part Number-Testo 6456 DN80 (3 ")

Testo 6456 DN80 (3 ")

Available upon quote 4-20 ma 16 BAR (> DN200 14 BAR) 0 to 120 % of full scale values DN80 (3 ") III <90 % Can be changed by users. Settings at the time of factory: 0.13 %x final values ​​in the measurement range 10.6 kg <150 ma 500 Ω When compressed air purifying class 1 (particles) / 5 (humidity and moisture) / 1 (oil): ± (3 %x measured+ 0.3 %x final value of measurement range) Compressed air -10 ~+60 ° C /+14 ~+140 ° f 0555 6456 2 0 to +60 ° C 18-30 VDC (EN 50178 SELV / Pelv) 160 mm IP 65: IP 67 VDC / 2 V ± (1.5 % x measurement value) -20 to +85 ° C C ± (measured value x 0.07 %) 1/k ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) <80 ma 0.002-2s (depending on the pulse output value)
Thermal gas flow meter DN65-250 testo 6456-Part Number-Testo 6456 DN100 (4 ")

Testo 6456 DN100 (4 ")

Available upon quote 4-20 ma 16 BAR (> DN200 14 BAR) 0 to 120 % of full scale values DN100 (4 ") III <90 % Can be changed by users. Settings at the time of factory: 0.13 %x final values ​​in the measurement range 12.8 kg <150 ma 500 Ω When compressed air purifying class 1 (particles) / 5 (humidity and moisture) / 1 (oil): ± (3 %x measured+ 0.3 %x final value of measurement range) Compressed air -10 ~+60 ° C /+14 ~+140 ° f 0555 6456 2 0 to +60 ° C 18-30 VDC (EN 50178 SELV / Pelv) 160 mm IP 65: IP 67 VDC / 2 V ± (1.5 % x measurement value) -20 to +85 ° C C ± (measured value x 0.07 %) 1/k ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) <80 ma 0.002-2s (depending on the pulse output value)
Thermal gas flow meter DN65-250 testo 6456-Part Number-Testo 6456 DN125 (5 ")

Testo 6456 DN125 (5 ")

Available upon quote 4-20 ma 16 BAR (> DN200 14 BAR) 0 to 120 % of full scale values DN125 (5 ") III <90 % Can be changed by users. Settings at the time of factory: 0.13 %x final values ​​in the measurement range 20.6 kg <150 ma 500 Ω When compressed air purifying class 1 (particles) / 5 (humidity and moisture) / 1 (oil): ± (3 %x measured+ 0.3 %x final value of measurement range) Compressed air -10 ~+60 ° C /+14 ~+140 ° f 0555 6456 2 0 to +60 ° C 18-30 VDC (EN 50178 SELV / Pelv) 172 mm IP 65: IP 67 VDC / 2 V ± (1.5 % x measurement value) -20 to +85 ° C C ± (measured value x 0.07 %) 1/k ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) <80 ma 0.002-2s (depending on the pulse output value)
Thermal gas flow meter DN65-250 testo 6456-Part Number-Testo 6456 DN150 (6 ")

Testo 6456 DN150 (6 ")

Available upon quote 4-20 ma 16 BAR (> DN200 14 BAR) 0 to 120 % of full scale values DN150 (6 ") III <90 % Can be changed by users. Settings at the time of factory: 0.13 %x final values ​​in the measurement range 26.2 kg <150 ma 500 Ω When compressed air purifying class 1 (particles) / 5 (humidity and moisture) / 1 (oil): ± (3 %x measured+ 0.3 %x final value of measurement range) Compressed air -10 ~+60 ° C /+14 ~+140 ° f 0555 6456 2 0 to +60 ° C 18-30 VDC (EN 50178 SELV / Pelv) 180 mm IP 65: IP 67 VDC / 2 V ± (1.5 % x measurement value) -20 to +85 ° C C ± (measured value x 0.07 %) 1/k ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) <80 ma 0.002-2s (depending on the pulse output value)
Thermal gas flow meter DN65-250 testo 6456-Part Number-Testo 6456 DN200 (8 ")

Testo 6456 DN200 (8 ")

Available upon quote 4-20 ma 16 BAR (> DN200 14 BAR) 0 to 120 % of full scale values DN200 (8 ") III <90 % Can be changed by users. Settings at the time of factory: 0.13 %x final values ​​in the measurement range 36.6 kg <150 ma 500 Ω When compressed air purifying class 1 (particles) / 5 (humidity and moisture) / 1 (oil): ± (3 %x measured+ 0.3 %x final value of measurement range) Compressed air -10 ~+60 ° C /+14 ~+140 ° f 0555 6456 2 0 to +60 ° C 18-30 VDC (EN 50178 SELV / Pelv) 180 mm IP 65: IP 67 VDC / 2 V ± (1.5 % x measurement value) -20 to +85 ° C C ± (measured value x 0.07 %) 1/k ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) <80 ma 0.002-2s (depending on the pulse output value)
Thermal gas flow meter DN65-250 testo 6456-Part Number-Testo 6456 DN250 (10 ")

Testo 6456 DN250 (10 ")

Available upon quote 4-20 ma 16 BAR (> DN200 14 BAR) 0 to 120 % of full scale values DN250 (10 ") III <90 % Can be changed by users. Settings at the time of factory: 0.13 %x final values ​​in the measurement range 55.1 kg <150 ma 500 Ω When compressed air purifying class 1 (particles) / 5 (humidity and moisture) / 1 (oil): ± (3 %x measured+ 0.3 %x final value of measurement range) Compressed air -10 ~+60 ° C /+14 ~+140 ° f 0555 6456 2 0 to +60 ° C 18-30 VDC (EN 50178 SELV / Pelv) 196 mm IP 65: IP 67 VDC / 2 V ± (1.5 % x measurement value) -20 to +85 ° C C ± (measured value x 0.07 %) 1/k ± 0.5 k (applicable within the measurement range of flow velocity and flow rate) <80 ma 0.002-2s (depending on the pulse output value)

Click on the part number for more information about each product