About This Product

A protector that protects the regular monitoring equipment of railway signal equipment from abnormal voltages such as lightning surges.

  • Product

    Signal power supply system Protective device for steady state monitoring equipment

Share this product


220+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

7 Models of Signal power supply system Protective device for steady state monitoring equipment

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Frequency used Impedance ratio (L:T) Impulse protection level (between L1/L2-E) Impulse repetitive current withstand capacity Limit voltage (10/200μs, 200A applied) Mass Maximum allowable circuit voltage Maximum operating circuit voltage Maximum usage level Nominal circuit voltage Operating attenuation Power supply side DC discharge starting voltage Power supply side impulse voltage protection performance Series Size Surge transition rate Transmission band Transmission side DC discharge starting voltage (between L1/L2-E) Transmission side impulse voltage protection performance Withstand voltage
Signal power supply system Protective device for steady state monitoring equipment-Part Number-LH type (for AC)

LH type (for AC)

Available upon quote - 370Ω:600Ω - - Voltage to ground 500V or less Approximately 190g - AC130Vrms 10dBm - 0.5dB or less 400V±80V Voltage to ground 800V or less (10/200μs, 3kV applied) Protector terminal board LH series (W) 94mm× (D) 50mm× (H) 40mm - 0.3kHz~10kHz 400V±80V Voltage to ground: 80V or less, line voltage: 50V or less (10/200μs between L and E, 3kV applied) AC (50/60Hz) 3kV, 1 minute (T-E)
Signal power supply system Protective device for steady state monitoring equipment-Part Number-LH type (for DC)

LH type (for DC)

Available upon quote - 370Ω:600Ω - - Voltage to ground 500V or less Approximately 190g - DC31V 10dBm - 0.5dB or less 400V±80V Voltage to ground 800V or less (10/200μs, 3kV applied) Protector terminal board LH series (W) 94mm× (D) 50mm× (H) 40mm - 0.3kHz~10kHz 400V±80V Voltage to ground: 80V or less, line voltage: 50V or less (10/200μs between L and E, 3kV applied) AC (50/60Hz) 3kV, 1 minute (T-E)
Signal power supply system Protective device for steady state monitoring equipment-Part Number-S-K2-1

S-K2-1

Available upon quote - - 800V or less (10/200μs, 3kV applied) 10/200μs, 200A, 50 times 500V or less Approximately 80g AC260V (peak value), DC225V - - AC110V (effective value), DC150V - 280V or more - Protector terminal board S-K2-1 series (W) 80mm× (D) 45mm× (H) 25mm - - - - -
Signal power supply system Protective device for steady state monitoring equipment-Part Number-S-K2-1W

S-K2-1W

Available upon quote - - 800V or less (10/200μs, 3kV applied) 10/200μs, 400A, 50 times 500V or less Approximately 80g AC260V (peak value), DC225V - - AC110V (effective value), DC150V - 280V or more - Protector terminal board S-K2-1 series (W) 80mm× (D) 45mm× (H) 25mm - - - - -
Signal power supply system Protective device for steady state monitoring equipment-Part Number-SU10L33 type

SU10L33 type

Available upon quote 0.3~5kHz 370Ω: 370Ω - - - Approximately 600g - - 25dBm - 0.5dB or less - - Lightning-resistant transformer SU10L series for transmission (W) 160mm× (D) 48mm× (H) 105mm 1/100 or less - - - AC10kV for 1 minute, impulse 1.2/50μs30kV
Signal power supply system Protective device for steady state monitoring equipment-Part Number-SU10L36 type

SU10L36 type

Available upon quote 0.3~5kHz 370Ω:600Ω - - - Approximately 600g - - 25dBm - 0.5dB or less - - Lightning-resistant transformer SU10L series for transmission (W) 160mm× (D) 48mm× (H) 105mm 1/100 or less - - - AC10kV for 1 minute, impulse 1.2/50μs30kV
Signal power supply system Protective device for steady state monitoring equipment-Part Number-SU10L66 type

SU10L66 type

Available upon quote 0.3~5kHz 600Ω: 600Ω - - - Approximately 600g - - 25dBm - 0.5dB or less - - Lightning-resistant transformer SU10L series for transmission (W) 160mm× (D) 48mm× (H) 105mm 1/100 or less - - - AC10kV for 1 minute, impulse 1.2/50μs30kV

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Sankosha Co., Ltd.


View more products of Sankosha Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree