Product Image | Part Number | Price (excluding tax) | Ambient humidity | Ambient temperature | Atmosphere | Connection method | Insulation resistance | Mass | Noise resistance | Power consumption | Power supply voltage | Shockproof | Storage temperature | Synchronization method | Transmission distance | Transmission method | Transmission procedure | Transmission speed | Vibration resistance | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VAH-101-Z12 |
Available upon quote | 35~85%RH | 0~+50℃ | No conductive dust or corrosive gas | Multidrop connection | 20MΩ or more between external terminal and outer box | 510g | 1,200Vp-p (pulse width 1μs) | 6.0W | DC24V+15%-10% | 100m/s2 | -20~+70℃ | Pit synchronization method | Maximum 200m | Bidirectional time division multiplexing transmission system | Uniline protocol | 7.35kbps | Compliant with JIS C 0040 | Between external terminal and outer box: AC1000V for 1 minute | |
VAH-101-Z58 |
Available upon quote | 35~85%RH | 0~+50℃ | No conductive dust or corrosive gas | Multidrop connection | 20MΩ or more between external terminal and outer box | 510g | 1,200Vp-p (pulse width 1μs) | 6.0W | DC24V+15%-10% | 100m/s2 | -20~+70℃ | Pit synchronization method | Maximum 200m | Bidirectional time division multiplexing transmission system | Uniline protocol | 7.35kbps | Compliant with JIS C 0040 | Between external terminal and outer box: AC1000V for 1 minute | |
VAH-102-Z12 |
Available upon quote | 35~85%RH | 0~+50℃ | No conductive dust or corrosive gas | Multidrop connection | 20MΩ or more between external terminal and outer box | 510g | 1,200Vp-p (pulse width 1μs) | 3.0W | DC24V+15%-10% | 100m/s2 | -20~+70℃ | Pit synchronization method | Maximum 200m | Bidirectional time division multiplexing transmission system | Uniline protocol | 7.35kbps | Compliant with JIS C 0040 | Between external terminal and outer box: AC1000V for 1 minute | |
VAH-102-Z58 |
Available upon quote | 35~85%RH | 0~+50℃ | No conductive dust or corrosive gas | Multidrop connection | 20MΩ or more between external terminal and outer box | 510g | 1,200Vp-p (pulse width 1μs) | 3.0W | DC24V+15%-10% | 100m/s2 | -20~+70℃ | Pit synchronization method | Maximum 200m | Bidirectional time division multiplexing transmission system | Uniline protocol | 7.35kbps | Compliant with JIS C 0040 | Between external terminal and outer box: AC1000V for 1 minute |