Gateway for Modbus-SDD-485MB
Gateway for Modbus-NKE Corporation

Gateway for Modbus
NKE Corporation


About This Product

SDD-485MB is a device (gateway) for connecting Uniline and RS-485 Modbus. Uniline's wide variety of input/output devices can be used in systems that mainly use RS-485 Modbus. It has Uniline send unit function and RS-485 Modbus-RTU communication function. Be sure to use the 256-point specification for the terminal unit. Modbus communication is possible with the general-purpose 485 port.

  • Product

    Gateway for Modbus

Share this product


100+ people viewing

Last viewed: 8 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Gateway for Modbus

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Ambient temperature Atmosphere Modbus communication method Modbus communication speed Modbus error control Modbus slave address Modbus synchronization method Modbus transmission format Modbus transmission protocol Number of Modbus connections Number of connected terminals on Uniline side Operating humidity Storage temperature Type Uniline side I/O points Uniline side Uniline port Uniline side mass Uniline side monitor terminal Uniline side refresh cycle time Uniline side synchronization method Uniline side transmission delay time Uniline side transmission distance Uniline side transmission method Uniline side transmission procedure
Gateway for Modbus-Part Number-SDD-485MB

SDD-485MB

Available upon quote 0℃~+50℃ No corrosive or flammable gas Single master/multi-slave system 19,200/9,600/4,800bps (set with slide switch) CRC-16 (Modbus) Setting range 1~63 (Set with slide switch) Start-stop synchronization method 8 bits of data, even parity, 1 stop bit Modbus-RTU compliant 16 units 20 units 35%~85%RH (no condensation) -20℃~+70℃ Basic specifications, Uniline transmission distance 200m 256 points (256 points x 1 port) Set input/output assignment using MODE switch 1 port, connector 160g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. 200m 11.4mS Max., 500m 21.1mS Max., 1km 39.4mS Max. Bit synchronization method 200m 22.8mS Max., 500m 42.2mS Max., 1km 79.0mS Max. Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for Modbus-Part Number-SDD-485MB-C

SDD-485MB-C

Available upon quote 0℃~+50℃ No corrosive or flammable gas Single master/multi-slave system 19,200/9,600/4,800bps (set with slide switch) CRC-16 (Modbus) Setting range 1~63 (Set with slide switch) Start-stop synchronization method 8 bits of data, even parity, 1 stop bit Modbus-RTU compliant 16 units 20 units 35%~85%RH (no condensation) -20℃~+70℃ C specification, Uniline transmission distance 200m 256 points (256 points x 1 port) Set input/output assignment using MODE switch 1 port, connector 160g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. 200m 11.4mS Max., 500m 21.1mS Max., 1km 39.4mS Max. Bit synchronization method 200m 22.8mS Max., 500m 42.2mS Max., 1km 79.0mS Max. Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for Modbus-Part Number-SDD-485MB-S

SDD-485MB-S

Available upon quote 0℃~+50℃ No corrosive or flammable gas Single master/multi-slave system 19,200/9,600/4,800bps (set with slide switch) CRC-16 (Modbus) Setting range 1~63 (Set with slide switch) Start-stop synchronization method 8 bits of data, even parity, 1 stop bit Modbus-RTU compliant 16 units 20 units 35%~85%RH (no condensation) -20℃~+70℃ S specification, Uniline transmission distance 500m 256 points (256 points x 1 port) Set input/output assignment using MODE switch 1 port, connector 160g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. 200m 11.4mS Max., 500m 21.1mS Max., 1km 39.4mS Max. Bit synchronization method 200m 22.8mS Max., 500m 42.2mS Max., 1km 79.0mS Max. Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for Modbus-Part Number-SDD-485MB-M

SDD-485MB-M

Available upon quote 0℃~+50℃ No corrosive or flammable gas Single master/multi-slave system 19,200/9,600/4,800bps (set with slide switch) CRC-16 (Modbus) Setting range 1~63 (Set with slide switch) Start-stop synchronization method 8 bits of data, even parity, 1 stop bit Modbus-RTU compliant 16 units 20 units 35%~85%RH (no condensation) -20℃~+70℃ M specification, Uniline transmission distance 500m 256 points (256 points x 1 port) Set input/output assignment using MODE switch 1 port, connector 160g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. 200m 11.4mS Max., 500m 21.1mS Max., 1km 39.4mS Max. Bit synchronization method 200m 22.8mS Max., 500m 42.2mS Max., 1km 79.0mS Max. Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for Modbus-Part Number-SDD-485MB-Z12

SDD-485MB-Z12

Available upon quote 0℃~+50℃ No corrosive or flammable gas Single master/multi-slave system 19,200/9,600/4,800bps (set with slide switch) CRC-16 (Modbus) Setting range 1~63 (Set with slide switch) Start-stop synchronization method 8 bits of data, even parity, 1 stop bit Modbus-RTU compliant 16 units 20 units 35%~85%RH (no condensation) -20℃~+70℃ Z12 specification, Uniline transmission distance 1km 256 points (256 points x 1 port) Set input/output assignment using MODE switch 1 port, connector 160g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. 200m 11.4mS Max., 500m 21.1mS Max., 1km 39.4mS Max. Bit synchronization method 200m 22.8mS Max., 500m 42.2mS Max., 1km 79.0mS Max. Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for Modbus-Part Number-SDD-485MB-Z58

SDD-485MB-Z58

Available upon quote 0℃~+50℃ No corrosive or flammable gas Single master/multi-slave system 19,200/9,600/4,800bps (set with slide switch) CRC-16 (Modbus) Setting range 1~63 (Set with slide switch) Start-stop synchronization method 8 bits of data, even parity, 1 stop bit Modbus-RTU compliant 16 units 20 units 35%~85%RH (no condensation) -20℃~+70℃ Z58 specification, Uniline transmission distance 1km 256 points (256 points x 1 port) Set input/output assignment using MODE switch 1 port, connector 160g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. 200m 11.4mS Max., 500m 21.1mS Max., 1km 39.4mS Max. Bit synchronization method 200m 22.8mS Max., 500m 42.2mS Max., 1km 79.0mS Max. Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol

Click on the part number for more information about each product