Gateway for CC-Link-SDD-CC1A
Gateway for CC-Link-NKE Corporation

Gateway for CC-Link
NKE Corporation


About This Product

SDD-CC1A is a device (gateway) for connecting Uniline and CC-Link. (SDD-CC1A upward compatible version) Uniline's wide variety of input/output devices can be used in a system based on CC-Link. It has Uniline's send unit function and CC-Link communication function. Be sure to use the 256-point specification for the terminal unit. Each 16 input and output points are used as the system area, so the actual number of points used is 112 input points and 112 output points.

  • Product

    Gateway for CC-Link

Share this product


100+ people viewing

Last viewed: 6 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Gateway for CC-Link

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Ambient temperature Atmosphere CC-Link RAS function CC-Link communication method CC-Link communication speed CC-Link connection cable CC-Link encoding method CC-Link error control CC-Link remote station number CC-Link station type CC-Link synchronization method CC-Link transmission format CC-Link transmission line format CC-Link version Number of CC-Link occupied stations Number of connected terminals on Uniline side Operating humidity Storage temperature Type Uniline side I/O points Uniline side Uniline port Uniline side mass Uniline side monitor terminal Uniline side refresh cycle time Uniline side synchronization method Uniline side transmission distance Uniline side transmission method Uniline side transmission procedure
Gateway for CC-Link-Part Number-SDD-CC1A

SDD-CC1A

Available upon quote 0℃~+50℃ No corrosive or flammable gas Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) Broadcast polling method 10M/5M/2.5M/625K/156Kbps (switchable by switch) CC-Link cable (shielded 3-core twisted pair cable) NRZI CRC (X16+X12+X5+1) Station number setting range 1~61 (switchable by switch) Remote device station Frame synchronization method HDLC compliant Bus format (EIA RS485 compliant) CC-Link ver.1.10 4 stations occupied 20 units 35%~85%RH (no condensation) -20℃~+70℃ Basic specifications, Uniline transmission distance 200m 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) 1 port, terminal block 210g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms Bit synchronization method Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for CC-Link-Part Number-SDD-CC1A-C

SDD-CC1A-C

Available upon quote 0℃~+50℃ No corrosive or flammable gas Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) Broadcast polling method 10M/5M/2.5M/625K/156Kbps (switchable by switch) CC-Link cable (shielded 3-core twisted pair cable) NRZI CRC (X16+X12+X5+1) Station number setting range 1~61 (switchable by switch) Remote device station Frame synchronization method HDLC compliant Bus format (EIA RS485 compliant) CC-Link ver.1.10 4 stations occupied 20 units 35%~85%RH (no condensation) -20℃~+70℃ C specification, Uniline transmission distance 200m 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) 1 port, terminal block 210g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms Bit synchronization method Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for CC-Link-Part Number-SDD-CC1A-S

SDD-CC1A-S

Available upon quote 0℃~+50℃ No corrosive or flammable gas Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) Broadcast polling method 10M/5M/2.5M/625K/156Kbps (switchable by switch) CC-Link cable (shielded 3-core twisted pair cable) NRZI CRC (X16+X12+X5+1) Station number setting range 1~61 (switchable by switch) Remote device station Frame synchronization method HDLC compliant Bus format (EIA RS485 compliant) CC-Link ver.1.10 4 stations occupied 20 units 35%~85%RH (no condensation) -20℃~+70℃ S specification, Uniline transmission distance 500m 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) 1 port, terminal block 210g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms Bit synchronization method Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for CC-Link-Part Number-SDD-CC1A-M

SDD-CC1A-M

Available upon quote 0℃~+50℃ No corrosive or flammable gas Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) Broadcast polling method 10M/5M/2.5M/625K/156Kbps (switchable by switch) CC-Link cable (shielded 3-core twisted pair cable) NRZI CRC (X16+X12+X5+1) Station number setting range 1~61 (switchable by switch) Remote device station Frame synchronization method HDLC compliant Bus format (EIA RS485 compliant) CC-Link ver.1.10 4 stations occupied 20 units 35%~85%RH (no condensation) -20℃~+70℃ M specification, Uniline transmission distance 500m 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) 1 port, terminal block 210g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms Bit synchronization method Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for CC-Link-Part Number-SDD-CC1A-Z12

SDD-CC1A-Z12

Available upon quote 0℃~+50℃ No corrosive or flammable gas Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) Broadcast polling method 10M/5M/2.5M/625K/156Kbps (switchable by switch) CC-Link cable (shielded 3-core twisted pair cable) NRZI CRC (X16+X12+X5+1) Station number setting range 1~61 (switchable by switch) Remote device station Frame synchronization method HDLC compliant Bus format (EIA RS485 compliant) CC-Link ver.1.10 4 stations occupied 20 units 35%~85%RH (no condensation) -20℃~+70℃ Z12 specification, Uniline transmission distance 1km 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) 1 port, terminal block 210g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms Bit synchronization method Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol
Gateway for CC-Link-Part Number-SDD-CC1A-Z58

SDD-CC1A-Z58

Available upon quote 0℃~+50℃ No corrosive or flammable gas Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) Broadcast polling method 10M/5M/2.5M/625K/156Kbps (switchable by switch) CC-Link cable (shielded 3-core twisted pair cable) NRZI CRC (X16+X12+X5+1) Station number setting range 1~61 (switchable by switch) Remote device station Frame synchronization method HDLC compliant Bus format (EIA RS485 compliant) CC-Link ver.1.10 4 stations occupied 20 units 35%~85%RH (no condensation) -20℃~+70℃ Z58 specification, Uniline transmission distance 1km 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) 1 port, terminal block 210g Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms Bit synchronization method Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km Bidirectional time division multiplexing transmission system Uniline protocol

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of NKE Corporation


View more products of NKE Corporation