Product
Gateway for CC-LinkHandling Company
NKE CorporationCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Atmosphere | CC-Link RAS function | CC-Link communication method | CC-Link communication speed | CC-Link connection cable | CC-Link encoding method | CC-Link error control | CC-Link remote station number | CC-Link station type | CC-Link synchronization method | CC-Link transmission format | CC-Link transmission line format | CC-Link version | Number of CC-Link occupied stations | Number of connected terminals on Uniline side | Operating humidity | Storage temperature | Type | Uniline side I/O points | Uniline side Uniline port | Uniline side mass | Uniline side monitor terminal | Uniline side refresh cycle time | Uniline side synchronization method | Uniline side transmission distance | Uniline side transmission method | Uniline side transmission procedure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SDD-CC1A |
Available upon quote | 0℃~+50℃ | No corrosive or flammable gas | Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) | Broadcast polling method | 10M/5M/2.5M/625K/156Kbps (switchable by switch) | CC-Link cable (shielded 3-core twisted pair cable) | NRZI | CRC (X16+X12+X5+1) | Station number setting range 1~61 (switchable by switch) | Remote device station | Frame synchronization method | HDLC compliant | Bus format (EIA RS485 compliant) | CC-Link ver.1.10 | 4 stations occupied | 20 units | 35%~85%RH (no condensation) | -20℃~+70℃ | Basic specifications, Uniline transmission distance 200m | 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) | 1 port, terminal block | 210g | Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. | Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms | Bit synchronization method | Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km | Bidirectional time division multiplexing transmission system | Uniline protocol | |
SDD-CC1A-C |
Available upon quote | 0℃~+50℃ | No corrosive or flammable gas | Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) | Broadcast polling method | 10M/5M/2.5M/625K/156Kbps (switchable by switch) | CC-Link cable (shielded 3-core twisted pair cable) | NRZI | CRC (X16+X12+X5+1) | Station number setting range 1~61 (switchable by switch) | Remote device station | Frame synchronization method | HDLC compliant | Bus format (EIA RS485 compliant) | CC-Link ver.1.10 | 4 stations occupied | 20 units | 35%~85%RH (no condensation) | -20℃~+70℃ | C specification, Uniline transmission distance 200m | 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) | 1 port, terminal block | 210g | Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. | Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms | Bit synchronization method | Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km | Bidirectional time division multiplexing transmission system | Uniline protocol | |
SDD-CC1A-S |
Available upon quote | 0℃~+50℃ | No corrosive or flammable gas | Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) | Broadcast polling method | 10M/5M/2.5M/625K/156Kbps (switchable by switch) | CC-Link cable (shielded 3-core twisted pair cable) | NRZI | CRC (X16+X12+X5+1) | Station number setting range 1~61 (switchable by switch) | Remote device station | Frame synchronization method | HDLC compliant | Bus format (EIA RS485 compliant) | CC-Link ver.1.10 | 4 stations occupied | 20 units | 35%~85%RH (no condensation) | -20℃~+70℃ | S specification, Uniline transmission distance 500m | 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) | 1 port, terminal block | 210g | Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. | Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms | Bit synchronization method | Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km | Bidirectional time division multiplexing transmission system | Uniline protocol | |
SDD-CC1A-M |
Available upon quote | 0℃~+50℃ | No corrosive or flammable gas | Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) | Broadcast polling method | 10M/5M/2.5M/625K/156Kbps (switchable by switch) | CC-Link cable (shielded 3-core twisted pair cable) | NRZI | CRC (X16+X12+X5+1) | Station number setting range 1~61 (switchable by switch) | Remote device station | Frame synchronization method | HDLC compliant | Bus format (EIA RS485 compliant) | CC-Link ver.1.10 | 4 stations occupied | 20 units | 35%~85%RH (no condensation) | -20℃~+70℃ | M specification, Uniline transmission distance 500m | 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) | 1 port, terminal block | 210g | Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. | Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms | Bit synchronization method | Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km | Bidirectional time division multiplexing transmission system | Uniline protocol | |
SDD-CC1A-Z12 |
Available upon quote | 0℃~+50℃ | No corrosive or flammable gas | Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) | Broadcast polling method | 10M/5M/2.5M/625K/156Kbps (switchable by switch) | CC-Link cable (shielded 3-core twisted pair cable) | NRZI | CRC (X16+X12+X5+1) | Station number setting range 1~61 (switchable by switch) | Remote device station | Frame synchronization method | HDLC compliant | Bus format (EIA RS485 compliant) | CC-Link ver.1.10 | 4 stations occupied | 20 units | 35%~85%RH (no condensation) | -20℃~+70℃ | Z12 specification, Uniline transmission distance 1km | 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) | 1 port, terminal block | 210g | Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. | Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms | Bit synchronization method | Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km | Bidirectional time division multiplexing transmission system | Uniline protocol | |
SDD-CC1A-Z58 |
Available upon quote | 0℃~+50℃ | No corrosive or flammable gas | Automatic double-row function, slave station disconnection function, data link status confirmation, offline test (hardware test, line test, parameter confirmation test) | Broadcast polling method | 10M/5M/2.5M/625K/156Kbps (switchable by switch) | CC-Link cable (shielded 3-core twisted pair cable) | NRZI | CRC (X16+X12+X5+1) | Station number setting range 1~61 (switchable by switch) | Remote device station | Frame synchronization method | HDLC compliant | Bus format (EIA RS485 compliant) | CC-Link ver.1.10 | 4 stations occupied | 20 units | 35%~85%RH (no condensation) | -20℃~+70℃ | Z58 specification, Uniline transmission distance 1km | 256 points Select the operation mode (input/output assignment) with the MODE switch. However, in the case of operation MODE 0, 112 input points/112 output points (16 remote input/output points each are used as system area) | 1 port, terminal block | 210g | Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. | Basic/C specification approximately 11ms, S/M specification approximately 22ms, Z12/Z58 specification approximately 44ms | Bit synchronization method | Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km | Bidirectional time division multiplexing transmission system | Uniline protocol |
Click on the part number for more information about each product