Product
Interface for PLCHandling Company
NKE CorporationCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Installation location | Mass | Monitor terminal | Noise resistance | Number of I/O points | Number of connected terminals | Operating humidity | Refresh cycle time (128 points) | Refresh cycle time (256 points) | Refresh cycle time (64 points) | Storage humidity | Storage temperature | Synchronization method | Transmission delay time (128 points) | Transmission delay time (256 points) | Transmission delay time (64 points) | Transmission distance | Transmission method | Transmission procedure | Uniline port | Usage atmosphere | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MQ-HUW |
Available upon quote | 0℃~+55℃ | Inside the control panel | - | Monitor unit RM-120 enables monitoring of ON/OFF status and abnormal ID, and forced ON/OFF. | - | 128 points or 256 points (input and output can be selected for each 16 points) | 20 units | 5%~95%RH (no condensation) | 200m approx. 5.1ms, 500m approx. 10.1ms, 1km approx. 20.0ms | 200m approx. 9.6ms, 500m approx. 18.9ms, 1km approx. 37.5ms | - | 5%~95%RH (no condensation) | -25℃~+75℃ | Bit synchronization method | 200m approx. 5.9~11.0ms, 500m approx. 11.4~21.5ms, 1km approx. 22.4~42.4ms | 200m approx. 10.4~20.0ms, 500m approx. 20.2~39.1ms, 1km approx. 39.9~77.4ms | - | Select total length: 200m, 500m, 1km | Bidirectional time division multiplexing transmission system | Uniline protocol | 1 port, removable terminal block | Free of corrosive gases | - | |
OMCJ1-HUW |
Available upon quote | 0℃~+55℃ | - | 100g | ON/OFF status can be monitored using the separately sold monitor unit RM-120 | 1,500Vp-p (pulse width 1μs, 100ns) | 128 points (input/output combination 128/0.64/64.0/128), 256 points (input/output combination 256/0.128/128.0/256,192/64) | 20 units | 35%~85%RH (no condensation) | 200m approx. 5.1ms, 500m approx. 10.1ms, 1km approx. 20ms | 200m approx. 9.6ms, 500m approx. 18.9ms, 1km approx. 37.5ms | - | - | -20℃~+70℃ | Bit synchronization method | 200m approx. 11.0ms, 500m approx. 21.5ms, 1km approx. 42.4ms | 200m approx. 20.0ms, 500m approx. 39.1ms, 1km approx. 77.4ms | - | Basic/C specification 200m, S/M specification 500m, Z12/Z58 specification 1km | Bidirectional time division multiplexing transmission system | Uniline protocol | 1 port, removable terminal block | No corrosive or flammable gas | 1,000V (Uniline side external terminal and PLC side) | |
F3SVH64A |
Available upon quote | 0℃~+50℃ | - | 140g | Monitor unit RM-120 (sold separately) enables monitoring of ON/OFF status, forced ON/OFF, and error ID monitoring. | - | Select 64 points, 128 points, or 256 points with the dip switch, and select the operation mode (input/output assignment) with the rotary switch. | - | 35%~85%RH (no condensation) | Without monitor connection: 200m 5.8ms, 500m 10.9ms, 1km 20.6ms/With monitor connection: 200m 6.5ms, 500m 11.5ms, 1km 21.0ms | Without monitor connection: 200m 11.0ms, 500m 20.5ms, 1km 41.0ms/With monitor connection: 200m 11.5ms, 500m 21.0ms, 1km 42.0ms | Without monitor connection: 200m 3.3ms, 500m 6.2ms, 1km 11.7ms/With monitor connection: 200m 4.0ms, 500m 6.8ms, 1km 12.0ms | - | -20℃~+70℃ | - | Without monitor connection: 200m 11.6ms, 500m 21.8ms, 1km 41.2ms/With monitor connection: 200m 13.0ms, 500m 23.0ms, 1km 42.0ms | Without monitor connection: 200m 22.0ms, 500m 41.0ms, 1km 82.0ms/With monitor connection: 200m 23.0ms, 500m 42.0ms, 1km 84.0ms | Without monitor connection: 200m 6.6ms, 500m 12.4ms, 1km 23.4ms/With monitor connection: 200m 8.0ms, 500m 13.6ms, 1km 24.0ms | Select total length: 200m, 500m, 1km | Synchronization/multiplexing method | Uniline protocol | 1 port (20 addresses Max.) | No corrosive or flammable gas | - |
Click on the part number for more information about each product