Product
Process pH electrode Polylite Plus H for monitoring chemical processes and wastewater, etc.Handling Company
T&C Technical Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | ATEX/IECEx | Attached certificate | Certification | Cleaning sterilization performance | Conductivity | Diaphragm part | Electrical connection standards | Electrode | Electrolyte | Electrolyte replenishment | Glass | How to save | Measurement principle | Measuring range | Membrane shape | Number of diaphragms | O-ring | Operating temperature range | Process connection standard | Process pressure | Reference electrode | Sensitivity | Shaft diameter | Shaft length | Temperature sensor | Zero point |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
242428-1213 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | S8 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 120mm | None | Within 0±20mV | |
242428-1223 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | S8 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 225mm | None | Within 0±20mV | |
242428-1233 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | S8 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 325mm | None | Within 0±20mV | |
242428-1253 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | S8 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 425mm | None | Within 0±20mV | |
242428-1111 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | VP6 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 120mm | Pt100 | Within 0±20mV | |
242428-1121 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | VP6 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 225mm | Pt100 | Within 0±20mV | |
242428-1131 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | VP6 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 325mm | Pt100 | Within 0±20mV | |
242428-1151 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | VP6 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 425mm | Pt100 | Within 0±20mV | |
242428-1112 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | VP6 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 120mm | Pt1000 | Within 0±20mV | |
242428-1122 |
Available upon quote |
II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x ℃ Da/Db |
With NIST trace buffer Test result certificate |
F.D.A. | SIP / autoclave | 2μS/cm or more | Single pore | VP6 | Glass | Polysolve plus | Not possible | Hamilton h glass | Dedicated storage solution or 3molKCl | Composite electrode | PH0~14 | Cylindrical | 2 | FKM | 0~130℃ | PG13.5 |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Hamilton Everref L | 57~59mV/pH@25℃ | 12mm | 225mm | Pt1000 | Within 0±20mV |
Click on the part number for more information about each product