Fixed infrared camera for gas detection FLIR GF77a-FLIR GF77a 25° CH4 (7-8.5 µm)
Fixed infrared camera for gas detection FLIR GF77a-FLIR GF77f 25°
Fixed infrared camera for gas detection FLIR GF77a-Frier Systems Japan Co., Ltd.

Fixed infrared camera for gas detection FLIR GF77a
Frier Systems Japan Co., Ltd.


About This Product

The FLIR GF77a is FLIR Systems' first uncooled automatic leak detection camera designed specifically for methane gas visualization. This affordable fixed camera solution provides upstream/midstream gas processors, producers, or operators with the functionality they need to continuously monitor the potential hazards of invisible methane gas leaks. Provide. The small and lightweight FLIR GF77a includes FLIR patented features such as High Sensitivity Mode (HSM) to help visualize gases. GF77a helps oil and gas companies maintain valuable capital equipment, avoid product loss, meet emission reduction metrics, and maintain safer work procedures. GF77a also has a GF77f variant that includes a housing that withstands harsh environments. ■Affordable fixed OGI (infrared camera for gas detection) solution It offers industry-leading features for continuous monitoring, including high-sensitivity modes, remote motorized focus, and an open architecture for third-party integration. ■Visualization of industrial gases Spectral filtering allows you to detect methane gas and find the source of the leak while reducing direct inspection and ensuring worker safety. ■Excellent connectivity Compliant with RTSP, GigE, the GF77a has the flexibility to meet a variety of industrial communication needs and continuously detects gas leaks with network connectivity.

  • Product

    Fixed infrared camera for gas detection FLIR GF77a

Share this product


150+ people viewing

Last viewed: 8 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of Fixed infrared camera for gas detection FLIR GF77a

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy Camera frequency Communication and data storage Connection type Communication and data storage Digital input Communication and data storage Digital input/output connector type Communication and data storage Digital output Communication and data storage Digital output purpose Communication and data storage Ethernet communication Communication and data storage Ethernet connector type Communication and data storage Ethernet power supply Communication and data storage Ethernet video streaming Communication and data storage Serial communication Communication and data storage WiFi Communication and data storage connector Communication and data storage multicast Communication and data storage unicast Digital input Digital input/output connector type Digital output Digital output purpose Imaging and Lens Camera Frequency Imaging and Lens Gas Sensitivity (NECL) Imaging and Lens Video Lamp Imaging and lens contrast enhancement Imaging and lens overlays Imaging and lens spectral range Imaging and lenses FLIR screen - EST mode Imaging and lenses Image resolution Thermal resolution (NETD) Wifi
Fixed infrared camera for gas detection FLIR GF77a-Part Number-FLIR GF77a 25° CH4 (7-8.5 µm)

FLIR GF77a 25° CH4 (7-8.5 µm)

Available upon quote Ambient temperature 15℃~35℃, ‎When the temperature of the measuring object is 0℃ or higher, error ±5℃ 30Hz Wi-Fi: Peer to peer (ad hoc) or infrastructure (network) 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 male 12 pin A cord (shared with external power supply) 3x opto-isolated, 0~48VDC, max. 350mA (derated to 200mA at 60%; solid state opto-relay, 1x fault output (NC) only ・Set by program ・Fault (NC) ・GigE Vision ver. 1.2 ・Client API GenICam compliant ・TCP/IP socket-based FLIR Systems exclusive M12.8 pin X code, female Powered via Ethernet, PoE IEEE 802.3af Class 3 Can be Pan and tilt control: RS232 and RS485 exclusively Optional features, Wi-Fi standards – IEEE802.11a/b/g/n Pan/Tilt Control: M8 A-cord, male; Wi-Fi: Female RP-SMA (Pan/Tilt Control and Wi-Fi functionality are optional) RTSP protocol, GVSP (GigE Vision) protocol RTSP protocol, GVSP (GigE Vision) protocol 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 male 12 pin A cord (shared with external power supply) 3x opto-isolated, 0~48VDC, max. 350mA (derated to 200mA at 60%; solid state opto-relay, 1x fault output (NC) only ・Set by program ・Fault (NC) 30Hz CH4 (<100 ppm × m), N2O (<75 ppm × m), C3H8 (<400 ppm × m), SO2 (<30 ppm × m); ΔT=10℃, distance=1m Built-in LED light Histogram flattening for FSX, RTSP and GVSP video storage (infrared only), image source 0 Image source 0: RTSP protocol: Yes, No, GVSP (GigE Vision) protocol: Yes, No 7~8.5μm None 2,592×1,944 pixels <25mk at 30℃ (86°F) Optional features, Wi-Fi standards – IEEE802.11a/b/g/n
Fixed infrared camera for gas detection FLIR GF77a-Part Number-FLIR GF77f 25°

FLIR GF77f 25°

Available upon quote Range 1: -20°~80°C ±3°C, Range 2: 0°~250°C: 0°~100°C: ±3°C, 100°~250°C: ±3%, Range 3: 100°~500°C :±3% 30Hz Wi-Fi: peer-to-peer (ad hoc) or infrastructure (network) 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 male 12 pin A cord (shared with external power supply) 3 x opto-isolated, 0~48V DC, max. 350mA (reduced to 200mA at 60°C), solid state opto-relay, 1 x abnormal output (NC) only ・Set by program ・Abnormality (NC) ・GigE Vision ver. 1.2 ・Client API GenICam compliant ・TCP/IP socket-based FLIR Systems exclusive RJ45, female Power via Ethernet, PoE IEEE 802.3af Class 3 Can be Pan and tilt control: RS232 and RS485 only Wi-Fi standard – IEEE802.11a/b/g/n Pan and tilt control: M8 A-cord, male; Wi-Fi: female RP-SMA (pan/tilt function optional) RTSP protocol, GVSP (GigE Vision) protocol RTSP protocol, GVSP (GigE Vision) protocol 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 male 12 pin A cord (shared with external power supply) 3 x opto-isolated, 0~48VDC, max. 350mA (reduced to 200mA at 60°C), solid state opto-relay, 1 x abnormal output (NC) only ・Set by program ・Abnormality (NC) 30Hz CH4 (<100 ppm × m), N2O (<75 ppm × m), C3H8 (<400 ppm × m), SO2 (<30 ppm × m); ΔT=10℃, distance=1m Built-in LED light Histogram flattening for FSX, RTSP and GVSP video storage (infrared only), image source 0 Image source 0: RTSP protocol: Yes, No, GVSP (GigE Vision) protocol: Yes, No 7~8.5μm None 1,280×960 pixels <25mk (30℃) Wi-Fi standard – IEEE802.11a/b/g/n

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Frier Systems Japan Co., Ltd.


View more products of Frier Systems Japan Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree