Product
Fixed Thermography Camera FLIR Axxx Thermography Smart SensorHandling Company
Frier Systems Japan Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accuracy | Alarm function | Camera frequency | Communication and data storage Digital input | Communication and data storage Digital input purposes | Communication and data storage Digital input/output connector type | Communication and data storage Digital output | Communication and data storage Digital output purpose | Communication and data storage Ethernet | Communication and data storage Ethernet communication | Communication and data storage Ethernet connector type | Communication and data storage Ethernet interface | Communication and data storage Ethernet power supply | Communication and data storage Ethernet standards | Communication and data storage Ethernet type | Communication and data storage Image storage | Communication and data storage RS-232 | Communication and data storage Video storage | Communication and data storage WiFi | Communication and data storage encoding | Communication and data storage multicast | Digital input | Digital input/output connector type | Digital input/output isolation voltage | Digital output | Digital output purpose | Encoding | Ethernet interface | Temperature resolution_NETD | Wifi |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A400 + Smart Sensor (Advanced Model) |
Available upon quote | Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. | Each selected measurement function, digital input, internal camera temperature | 30Hz | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC, NUC disabled, alarm | M12 male 12 pin A cord (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | For control, results, images, and power | TCP/IP socket (FLIR proprietary) | M12 8-pin X code (female), RP-SMA (female) | Wired, Wi-Fi (optional feature) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | 1,000Mbps | Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature | - | Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm | Optional features sold separately. RP-SMA, female connector | Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 male 12 pin A cord (shared with external power supply) | 500VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric | Wired, Wi-Fi (optional feature) | Depends on the lens | Optional features sold separately. RP-SMA, female connector | |
A400 + Smart Sensor (Standard model) |
Available upon quote | Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. | Each selected measurement function, digital input, internal camera temperature | 30Hz | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC, NUC disabled, alarm | M12 male 12 pin A cord (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | For control, results, images, and power | TCP/IP socket (FLIR proprietary) | M12 8-pin X code (female), RP-SMA (female) | Wired, Wi-Fi (optional feature) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | 1,000Mbps | Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature | - | Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm | Optional features sold separately. RP-SMA, female connector | H.264, MPEG4, or MJPEG | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 male 12 pin A cord (shared with external power supply) | 500VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | H.264, MPEG4, or MJPEG | Wired, Wi-Fi (optional feature) | Depends on the lens | Optional features sold separately. RP-SMA, female connector | |
A500 + Smart Sensor Settings (Advanced Model) |
Available upon quote | Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. | Each selected measurement function, digital input, internal camera temperature | 30Hz | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC, NUC disabled, alarm | M12 male 12 pin A cord (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | For control, results, images, and power | TCP/IP socket (FLIR proprietary) | M12 8-pin X code (female), RP-SMA (female) | Wired, Wi-Fi (optional feature) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | 1,000Mbps | Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature | - | Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm | Optional features sold separately. RP-SMA, female connector | Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 male 12 pin A cord (shared with external power supply) | 500VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric | Wired, Wi-Fi (optional feature) | <30mK, 42° at 30°C, <40mK, 24° at 30°C, <50mK, 14° at 30°C | Optional features sold separately. RP-SMA, female connector | |
A500 + Smart Sensor Settings (Standard Model) |
Available upon quote | Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. | - | 30Hz | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (acc. SFNC 2.3): - Single frame (on trigger) - Multi frame (on trigger) - Continuous, etc. | M12 male 12 pin A cord (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Set by program; Failure (NC) | For control, results, images, and power | ・GigE Vision ver. 1.2 ・Client API GenICam compliant ・TCP/IP socket (FLIR Systems original) | M12 8-pin X code (female), RP-SMA (female) | Wired, Wi-Fi (optional feature) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | 1,000Mbps | - | M8 A code, male connector | - | Optional features sold separately. RP-SMA, female connector | RTSP video storage: H.264/MPEG4/MJPEG RTSP radiometric image transfer: Compressed JPEG-LS, FLIR radiometric GVSP video storage: Uncompressed, etc. | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 male 12 pin A cord (shared with external power supply) | 500VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Set by program; Failure (NC) | RTSP video storage: H.264/MPEG4/MJPEG RTSP radiometric image transfer: Compressed JPEG-LS, FLIR radiometric GVSP video storage: Uncompressed, etc. | Wired, Wi-Fi (optional feature) | <30mK, 42° at 30°C, <40mK, 24° at 30°C, <50mK, 14° at 30°C | Optional features sold separately. RP-SMA, female connector | |
A700 + Smart Sensor (Advanced Model) |
Available upon quote | Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. | For each selected measurement function, digital input, and camera internal temperature. | 30Hz | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC, NUC disabled, alarm | M12 12-pin A cord, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | For control, results, images, and power | TCP/IP socket (FLIR proprietary) | M12 8-pin X code (female), RP-SMA (female) | Wired, Wi-Fi (optional) | Powered via Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | 1,000Mbps | Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature | M8 A code, male connector | Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm | Optional parts sold separately. RP-SMA, female connector | Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A cord, male (shared with external power supply) | 500VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric | Wired, Wi-Fi (optional) | Depends on the lens | Optional parts sold separately. RP-SMA, female connector | |
A700 + Smart Sensor (Standard model) |
Available upon quote | Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. | For each selected measurement function, digital input, and camera internal temperature. | 30Hz | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC, NUC disabled, alarm | M12 12-pin A cord, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | For control, results, images, and power | TCP/IP socket (FLIR proprietary) | M12 8-pin X code (female), RP-SMA (female) | Wired, Wi-Fi (optional) | Powered via Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | 1,000Mbps | Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature | - | Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm | Optional features sold separately. RP-SMA, female connector | H.264, MPEG4, or MJPEG | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A cord, male (shared with external power supply) | 500VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | ・Output to external equipment as an alarm function ・Failure (NC) | H.264, MPEG4, or MJPEG | Wired, Wi-Fi (optional) | Depends on the lens | Optional parts sold separately. RP-SMA, female connector |
Click on the part number for more information about each product