Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor-A400 + Smart Sensor (Advanced Model)
Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor-Frier Systems Japan Co., Ltd.

Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor
Frier Systems Japan Co., Ltd.


About This Product

FLIR Axxx thermal imaging smart sensor cameras provide automation solution providers with the features they need to build complex monitoring systems, alarms, and achieve analysis goals. Smart sensors provide multiple measurement tools and alarm functions, as well as edge computing capabilities. Analysis can be performed at the camera level, so results can be seen immediately. With multiple viewing angle choices, motorized focus control, and unprecedented connectivity, the A400-A500-A700 cameras deliver unparalleled functionality and flexibility. This monitoring system is easy to configure, making it easy to use in-house. It can be tailored to meet your product quality, productivity, maintenance, and safety needs. ■Unparalleled network connectivity Connect to XML or JSON web services using RESTful API or integrate into HMI/SCADA systems via Modbus TCP or EtherNet/IP (Advanced model) ■Supporting improved decision making with advanced analysis Edge analysis using polygon functions (advanced models) etc. enables quick and informed decision-making ■World's top level thermal camera Outstanding image quality up to 640 x 480 (307,200 pixels) and excellent temperature measurement accuracy (<±2°C)

  • Product

    Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor

Share this product


180+ people viewing

Last viewed: 8 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy Alarm function Camera frequency Communication and data storage Digital input Communication and data storage Digital input purposes Communication and data storage Digital input/output connector type Communication and data storage Digital output Communication and data storage Digital output purpose Communication and data storage Ethernet Communication and data storage Ethernet communication Communication and data storage Ethernet connector type Communication and data storage Ethernet interface Communication and data storage Ethernet power supply Communication and data storage Ethernet standards Communication and data storage Ethernet type Communication and data storage Image storage Communication and data storage RS-232 Communication and data storage Video storage Communication and data storage WiFi Communication and data storage encoding Communication and data storage multicast Digital input Digital input/output connector type Digital input/output isolation voltage Digital output Digital output purpose Encoding Ethernet interface Temperature resolution_NETD Wifi
Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor-Part Number-A400 + Smart Sensor (Advanced Model)

A400 + Smart Sensor (Advanced Model)

Available upon quote Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. Each selected measurement function, digital input, internal camera temperature 30Hz 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 male 12 pin A cord (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) For control, results, images, and power TCP/IP socket (FLIR proprietary) M12 8-pin X code (female), RP-SMA (female) Wired, Wi-Fi (optional feature) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature - Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm Optional features sold separately. RP-SMA, female connector Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 male 12 pin A cord (shared with external power supply) 500VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric Wired, Wi-Fi (optional feature) Depends on the lens Optional features sold separately. RP-SMA, female connector
Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor-Part Number-A400 + Smart Sensor (Standard model)

A400 + Smart Sensor (Standard model)

Available upon quote Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. Each selected measurement function, digital input, internal camera temperature 30Hz 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 male 12 pin A cord (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) For control, results, images, and power TCP/IP socket (FLIR proprietary) M12 8-pin X code (female), RP-SMA (female) Wired, Wi-Fi (optional feature) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature - Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm Optional features sold separately. RP-SMA, female connector H.264, MPEG4, or MJPEG Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 male 12 pin A cord (shared with external power supply) 500VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) H.264, MPEG4, or MJPEG Wired, Wi-Fi (optional feature) Depends on the lens Optional features sold separately. RP-SMA, female connector
Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor-Part Number-A500 + Smart Sensor Settings (Advanced Model)

A500 + Smart Sensor Settings (Advanced Model)

Available upon quote Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. Each selected measurement function, digital input, internal camera temperature 30Hz 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 male 12 pin A cord (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) For control, results, images, and power TCP/IP socket (FLIR proprietary) M12 8-pin X code (female), RP-SMA (female) Wired, Wi-Fi (optional feature) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature - Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm Optional features sold separately. RP-SMA, female connector Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 male 12 pin A cord (shared with external power supply) 500VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric Wired, Wi-Fi (optional feature) <30mK, 42° at 30°C, <40mK, 24° at 30°C, <50mK, 14° at 30°C Optional features sold separately. RP-SMA, female connector
Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor-Part Number-A500 + Smart Sensor Settings (Standard Model)

A500 + Smart Sensor Settings (Standard Model)

Available upon quote Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. - 30Hz 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC; NUC disabled; Image tags (start, stop, general); Image flow control (acc. SFNC 2.3): - Single frame (on trigger) - Multi frame (on trigger) - Continuous, etc. M12 male 12 pin A cord (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only Set by program; Failure (NC) For control, results, images, and power ・GigE Vision ver. 1.2 ・Client API GenICam compliant ・TCP/IP socket (FLIR Systems original) M12 8-pin X code (female), RP-SMA (female) Wired, Wi-Fi (optional feature) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps - M8 A code, male connector - Optional features sold separately. RP-SMA, female connector RTSP video storage: H.264/MPEG4/MJPEG RTSP radiometric image transfer: Compressed JPEG-LS, FLIR radiometric GVSP video storage: Uncompressed, etc. Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 male 12 pin A cord (shared with external power supply) 500VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only Set by program; Failure (NC) RTSP video storage: H.264/MPEG4/MJPEG RTSP radiometric image transfer: Compressed JPEG-LS, FLIR radiometric GVSP video storage: Uncompressed, etc. Wired, Wi-Fi (optional feature) <30mK, 42° at 30°C, <40mK, 24° at 30°C, <50mK, 14° at 30°C Optional features sold separately. RP-SMA, female connector
Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor-Part Number-A700 + Smart Sensor (Advanced Model)

A700 + Smart Sensor (Advanced Model)

Available upon quote Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. For each selected measurement function, digital input, and camera internal temperature. 30Hz 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A cord, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) For control, results, images, and power TCP/IP socket (FLIR proprietary) M12 8-pin X code (female), RP-SMA (female) Wired, Wi-Fi (optional) Powered via Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature M8 A code, male connector Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm Optional parts sold separately. RP-SMA, female connector Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A cord, male (shared with external power supply) 500VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) Video storage: H.264, MPEG4, or MJPEG radiometric; Image transfer: compressed JPEG-LS, FLIR radiometric Wired, Wi-Fi (optional) Depends on the lens Optional parts sold separately. RP-SMA, female connector
Fixed Thermography Camera FLIR Axxx Thermography Smart Sensor-Part Number-A700 + Smart Sensor (Standard model)

A700 + Smart Sensor (Standard model)

Available upon quote Error: ±2°C or ±2% of reading value when ambient temperature is 15°C to 35°C and measurement target temperature is 0°C or higher. For each selected measurement function, digital input, and camera internal temperature. 30Hz 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A cord, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) For control, results, images, and power TCP/IP socket (FLIR proprietary) M12 8-pin X code (female), RP-SMA (female) Wired, Wi-Fi (optional) Powered via Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Record up to 100 FLIR radiometric JPEGs. Save as alarm, schedule, or user interaction (camera web) feature - Records up to 10 H.264 videos. Save as alarm function — 5 seconds before alarm and 5 seconds after alarm Optional features sold separately. RP-SMA, female connector H.264, MPEG4, or MJPEG Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A cord, male (shared with external power supply) 500VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only ・Output to external equipment as an alarm function ・Failure (NC) H.264, MPEG4, or MJPEG Wired, Wi-Fi (optional) Depends on the lens Optional parts sold separately. RP-SMA, female connector

Click on the part number for more information about each product