Product
Fixed type infrared thermography camera FLIR A50/A70 Dedicated image transfer cameraHandling Company
Frier Systems Japan Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accuracy | Communication and data storage Digital input | Communication and data storage Digital input purposes | Communication and data storage Digital input/output connector type | Communication and data storage Digital output | Communication and data storage Digital output purpose | Communication and data storage Ethernet | Communication and data storage Ethernet communication | Communication and data storage Ethernet connector type | Communication and data storage Ethernet interface | Communication and data storage Ethernet power supply | Communication and data storage Ethernet standards | Communication and data storage ONVIF Profile S compliant | Communication and data storage RS-232 | Communication and data storage Serial communication | Communication and data storage WiFi | Communication and data storage multicast | Digital input | Digital input/output connector type | Digital input/output isolation voltage | Digital output | Digital output purpose | Ethernet interface | Ethernet type | F value | Image frequency | Imaging and lenses F-number | Imaging and lenses MSX | Temperature resolution_NETD | Wifi |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A50 29° + Image Streaming Configuration (Advanced type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | Can be | M8 A-code, male connector | Pan & tilt control Pelco D standard HW interface: RS232 and RS485 only | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A50 29° + Image Streaming Configuration (Standard type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | No | M8 A-code, male connector | - | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A50 51° + Image Streaming Configuration (Advanced type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | Can be | M8 A-code, male connector | Pan & tilt control Pelco D standard HW interface: RS232 and RS485 only | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A50 51° + Image Streaming Configuration (Standard type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | No | M8 A-code, male connector | - | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A50 95° + Image Streaming Configuration (Advanced type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | Can be | M8 A-code, male connector | Pan & tilt control Pelco D standard HW interface: RS232 and RS485 only | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A50 95° + Image Streaming Configuration (Standard type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | No | M8 A-code, male connector | - | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A70 29° + Image Streaming Configuration (Advanced type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | Can be | M8 A-code, male connector | Pan & tilt control Pelco D standard HW interface: RS232 and RS485 only | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A70 29° + Image Streaming Configuration (Standard type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | No | M8 A-code, male connector | - | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A70 51°+ Image Streaming Configuration (Standard type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | No | M8 A-code, male connector | - | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector | |
A70 51°+ Image Streaming Configuration (Advanced type) |
Available upon quote | Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | NUC; NUC disabled; Image tags (start, stop, general); Image flow control (according to SFNC 2.3): - Single frame (when triggered) - Multi-frame (when triggered) - Continuous | M12 12-pin A-coded, male (shared with external power supply) | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | For control, results, images, and power | ・GigE Vision version 1.2 ・Compliant with Client API GenICam ・TCP/IP socket-based (FLIR proprietary) | M12 8-pin X-code, female, RP-SMA, female | Wired, Wi-Fi (optional) | Power over Ethernet, PoE IEEE 802.3af Class 3 | IEEE 802.3 | Can be | M8 A-code, male connector | Pan & tilt control Pelco D standard HW interface: RS232 and RS485 only | Optional features sold separately. RP-SMA, female connector | Can be | 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V | M12 12-pin A-coded, male (shared with external power supply) | 500 VRMS | 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only | Setting by program, abnormality (NC) | Wired, Wi-Fi (optional) | 1,000Mbps | 1.4 | 30Hz | 1.4 | Yes, included in the visual camera option | <35mK | Optional features sold separately. RP-SMA, female connector |
Click on the part number for more information about each product