Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-A50 29° + Smart Sensor Configuration (Advanced type)
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Frier Systems Japan Co., Ltd.

Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor
Frier Systems Japan Co., Ltd.


About This Product

FLIR A50 and A70 smart sensor cameras are ideal for users who require built-in on-camera analytics and alarm functionality for condition monitoring and early fire detection applications. With Wi-Fi, an integrated visual camera, and the option of ONVIF S compatibility (advanced version only), the FLIR A50/A70 cameras are flexible, configurable solutions that meet the unique needs of automation customers across a wide range of industries. Using A50/A70 cameras as system components for cloud and industrial Internet of Things (IIoT) solutions allows businesses to protect assets, improve safety, maximize uptime, and minimize maintenance costs. You can. ■High image quality Quickly access thermal properties with a wide-area, non-contact temperature sensor that provides up to 640 x 480 (307,200 pixels) resolution and ±2°C temperature accuracy. ■Trouble-free integration Simplify integration with thermal imaging smart sensors that communicate with standard industrial protocols and video management systems including HMI, SCADA, and optional ONVIF S compatibility. ■Sturdy and easy to install Multiple mounting options allow you to mount the lightweight, IP66 camera with M8/12 connectors anywhere. *Other model numbers are available.

  • Product

    Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor

Share this product


330+ people viewing

Last viewed: 20 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy Alarm function Communication and data storage Digital input Communication and data storage Digital input purposes Communication and data storage Digital input/output connector type Communication and data storage Digital input/output isolation voltage Communication and data storage Digital output Communication and data storage Digital output purpose Communication and data storage Ethernet Communication and data storage Ethernet communication Communication and data storage Ethernet connector type Communication and data storage Ethernet interface Communication and data storage Ethernet power supply Communication and data storage Ethernet standards Communication and data storage Ethernet type Communication and data storage ONVIF Profile S compliant Communication and data storage RS-232 Communication and data storage WiFi Communication and data storage encoding Communication and data storage multicast Digital input Digital input/output connector type Digital output Digital output purpose Encoding Ethernet interface F value Image frequency Temperature resolution_NETD Wifi
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A50 29° + Smart Sensor Configuration (Advanced type)

A50 29° + Smart Sensor Configuration (Advanced type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 box and mask polygons (total number) 3 deltas (any value/reference/external lock difference) 2 isotherms (top/bottom/interval) 2 equal coverage 1 reference temperature 2 lines 1 polyline 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Can be M8 A-code, male connector Optional features sold separately. RP-SMA, female connector Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A50 29° + Smart Sensor Configuration (Standard type)

A50 29° + Smart Sensor Configuration (Standard type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 boxes 3 deltas (any value/reference/external lock difference) 1 isotherm (top/bottom/interval) 1 class coverage 1 reference temperature 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps No M8 A-code, male connector Optional features sold separately. RP-SMA, female connector H.264, MPEG4, or MJPEG Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) H.264, MPEG4, or MJPEG Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A50 51° + Smart Sensor Configuration (Advanced type)

A50 51° + Smart Sensor Configuration (Advanced type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 box and mask polygons (total number) 3 deltas (any value/reference/external lock difference) 2 isotherms (top/bottom/interval) 2 equal coverage 1 reference temperature 2 lines 1 polyline 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Can be M8 A-code, male connector Optional features sold separately. RP-SMA, female connector Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A50 51° + Smart Sensor Configuration (Standard type)

A50 51° + Smart Sensor Configuration (Standard type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 boxes 3 deltas (any value/reference/external lock difference) 1 isotherm (top/bottom/interval) 1 class coverage 1 reference temperature 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps No M8 A-code, male connector Optional features sold separately. RP-SMA, female connector H.264, MPEG4, or MJPEG Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) H.264, MPEG4, or MJPEG Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A50 95° + Smart Sensor Configuration (Advanced type)

A50 95° + Smart Sensor Configuration (Advanced type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 box and mask polygons (total number) 3 deltas (any value/reference/external lock difference) 2 isotherms (top/bottom/interval) 2 equal coverage 1 reference temperature 2 lines 1 polyline 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Can be M8 A-code, male connector Optional features sold separately. RP-SMA, female connector Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A50 95° + S Smart Sensor Configuration (Standard type)

A50 95° + S Smart Sensor Configuration (Standard type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 boxes 3 deltas (any value/reference/external lock difference) 1 isotherm (top/bottom/interval) 1 class coverage 1 reference temperature 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps No M8 A-code, male connector Optional features sold separately. RP-SMA, female connector H.264, MPEG4, or MJPEG Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) H.264, MPEG4, or MJPEG Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A70 29° + Smart Sensor Configuration (Advanced type)

A70 29° + Smart Sensor Configuration (Advanced type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 box and mask polygons (total number) 3 deltas (any value/reference/external lock difference) 2 isotherms (top/bottom/interval) 2 equal coverage 1 reference temperature 2 lines 1 polyline 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Can be M8 A-code, male connector Optional features sold separately. RP-SMA, female connector Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A70 29° + Smart Sensor Configuration (Standard type)

A70 29° + Smart Sensor Configuration (Standard type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 boxes 3 deltas (any value/reference/external lock difference) 1 isotherm (top/bottom/interval) 1 class coverage 1 reference temperature 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps No M8 A-code, male connector Optional features sold separately. RP-SMA, female connector H.264, MPEG4, or MJPEG Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) H.264, MPEG4, or MJPEG Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A70 51° + Smart Sensor Configuration (Advanced type)

A70 51° + Smart Sensor Configuration (Advanced type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 box and mask polygons (total number) 3 deltas (any value/reference/external lock difference) 2 isotherms (top/bottom/interval) 2 equal coverage 1 reference temperature 2 lines 1 polyline 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps Can be M8 A-code, male connector Optional features sold separately. RP-SMA, female connector Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) Video stream: H.264, MPEG4, or MJPEG [BR] Radiometric stream: Compressed JPEG-LS, FLIR radiometric Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector
Fixed Infrared Thermography Camera FLIR A50/A70 Smart Sensor-Part Number-A70 51°+ Smart Sensor Configuration (Standard type)

A70 51°+ Smart Sensor Configuration (Standard type)

Available upon quote Ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher, ±2℃ or ±2% error (relative to read value) 10 spot meters 10 boxes 3 deltas (any value/reference/external lock difference) 1 isotherm (top/bottom/interval) 1 class coverage 1 reference temperature 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V NUC, NUC disabled, alarm M12 12-pin A-coded, male (shared with external power supply) 500 VRMS 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as an alarm function •Abnormality (NC) For control, results, images, and power TCP/IP socket-based (FLIR proprietary) M12 8-pin X-code, female, RP-SMA, female Wired, Wi-Fi (optional) Power over Ethernet, PoE IEEE 802.3af Class 3 IEEE 802.3 1,000Mbps No M8 A-code, male connector Optional features sold separately. RP-SMA, female connector H.264, MPEG4, or MJPEG Can be 2x opto-isolated, Vin (low) =0~1.5V, Vin (high) =3~25V M12 12-pin A-coded, male (shared with external power supply) 3x opto-isolated, 0~48V DC, max. 350mA, solid state opto-relay, 1x fault output (NC) only •Output to external device as alarm function, •Abnormality (NC) H.264, MPEG4, or MJPEG Wired, Wi-Fi (optional) 1.4 30Hz <35mK Optional features sold separately. RP-SMA, female connector

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Frier Systems Japan Co., Ltd.


View more products of Frier Systems Japan Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree