Product
Fixed thermal imaging camera FLIR A500f / A700f Advanced Smart Sensor for situation monitoring and early fire detectionHandling Company
Frier Systems Japan Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accuracy | Environment and Certification ETSI|EMC | Imaging and Lens Detector Spacing | Imaging and Lens Focal Length | Imaging and Lens Focus | Imaging and Lens Video Streaming | Imaging and Lenses Focal Plane Array [FPA] | Imaging and lens contrast enhancement | Imaging and lens multistreaming | Imaging and lens overlays | Imaging and lens spectral range | Imaging and lens streaming resolution | Imaging and lenses Detector time constants | Imaging and lenses F-number | Imaging and lenses Image frequency | Imaging and lenses Image resolution | Imaging and lenses Infrared resolution | Imaging and lenses Infrared video storage (with temperature information) | Imaging and lenses MSX | Imaging and lenses Minimum focal length | Infrared resolution | Measurement analysis Alarm function | Measurement analysis Atmospheric transmittance correction | Measurement analysis Automatic heat/cold sensing | Measurement analysis Measured value correction | Measurement analysis Measurement preset | Measurement analysis Target temperature range | Measurement analysis accuracy | Power supply Power consumption | User interface Web interface |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A500f Advanced Smart Sensor 42° |
Available upon quote | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | 17μm | 10mm | Motorized focus, manual and automatic on command (scene contrast method) | RTSP protocol | Uncooled microbolometer | FSX®/Histogram Flattening (IR only) | Can be | Yes/No | 7.5~14μm | Video stream 0: 640 x 480 pixels Video stream 1: 1,280 x 960 pixels Radiometric stream: 464 x 348 pixels | Normally 10ms | 1.1 | 30Hz | 1,280×960 | 464×348 | RTSP protocol to FLIR Atlas SDK | Can be | 0.15m (0.49ft) | 464×348 | For selected measurement functions, digital inputs, internal camera temperature, and timers. | Based on distance, atmospheric temperature, and relative humidity inputs | Maximum/minimum temperature value and position displayed in the box | Global object parameters. Local parameters per analytic function | Can be | -20℃~120℃ 0℃~650℃ 300℃~1,500℃ | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus | Can be | |
A500f Advanced Smart Sensor 14° |
Available upon quote | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | 17μm | 29mm | Motorized focus, manual and automatic on command (scene contrast method) | RTSP protocol | Uncooled microbolometer | FSX®/Histogram Flattening (IR only) | Can be | Yes/No | 7.5~14μm | Video stream 0: 640 x 480 pixels Video stream 1: 1,280 x 960 pixels Radiometric stream: 464 x 348 pixels | Normally 10ms | 1.5 | 30Hz | 1,280×960 | 464×348 | RTSP protocol to FLIR Atlas SDK | Can be | 1.0m (3.28ft) | 464×348 | For selected measurement functions, digital inputs, internal camera temperature, and timers. | Based on distance, atmospheric temperature, and relative humidity inputs | Maximum/minimum temperature value and position displayed in the box | Global object parameters. Local parameters per analytic function | Can be | -20℃~120℃ 0℃~650℃ 300℃~1,500℃ | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus | Can be | |
A500f Advanced Smart Sensor 24° |
Available upon quote | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | 17μm | 17mm | Motorized focus, manual and automatic on command (scene contrast method) | RTSP protocol | Uncooled microbolometer | FSX®/Histogram Flattening (IR only) | Can be | Yes/No | 7.5~14μm | Video stream 0: 640 x 480 pixels Video stream 1: 1,280 x 960 pixels Radiometric stream: 464 x 348 pixels | Normally 10ms | 1.3 | 30Hz | 1,280×960 | 464×348 | RTSP protocol to FLIR Atlas SDK | Can be | 0.15m (0.49ft) | 464×348 | For selected measurement functions, digital inputs, internal camera temperature, and timers. | Based on distance, atmospheric temperature, and relative humidity inputs | Maximum/minimum temperature value and position displayed in the box | Global object parameters. Local parameters per analytic function | Can be | -20℃~120℃ 0℃~650℃ 300℃~1,500℃ | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus | Can be | |
A700f Advanced Smart Sensor 14° |
Available upon quote | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | 12μm | 29mm | Motorized focus, manual and automatic on command (scene contrast method) | RTSP protocol | Uncooled microbolometer | FSX®/Histogram Flattening (IR only) | Can be | Yes/No | 7.5~14μm | Video stream 0: 640 x 480 pixels Video stream 1: 1,280 x 960 pixels Radiometric stream: 640 x 480 pixels | Normally 7ms | 1.5 | 30Hz | 1,280×960 | 640×480 | RTSP protocol to FLIR Atlas SDK | Can be | 1.0m (3.28ft) | 640×480 | For selected measurement functions, digital inputs, internal camera temperature, and timers. | Based on distance, atmospheric temperature, and relative humidity inputs | Maximum/minimum temperature value and position displayed in the box | Global object parameters. Local parameters per analytic function | Can be | -20℃~120℃ 0℃~650℃ 300℃~2,000℃ | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus | Can be | |
A700f Advanced Smart Sensor 24° |
Available upon quote | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | 12μm | 17mm | Motorized focus, manual and automatic on command (scene contrast method) | RTSP protocol | Uncooled microbolometer | FSX®/Histogram Flattening (IR only) | Can be | Yes/No | 7.5~14μm | Video stream 0: 640 x 480 pixels Video stream 1: 1,280 x 960 pixels Radiometric stream: 640 x 480 pixels | Normally 7ms | 1.3 | 30Hz | 1,280×960 | 640×480 | RTSP protocol to FLIR Atlas SDK | Can be | 0.15m (0.49ft) | 640×480 | For selected measurement functions, digital inputs, internal camera temperature, and timers. | Based on distance, atmospheric temperature, and relative humidity inputs | Maximum/minimum temperature value and position displayed in the box | Global object parameters. Local parameters per analytic function | Can be | -20℃~120℃ 0℃~650℃ 300℃~2,000℃ | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus | Can be | |
A700f Advanced Smart Sensor 42° |
Available upon quote | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | 12μm | 10mm | Motorized focus, manual and automatic on command (scene contrast method) | RTSP protocol | Uncooled microbolometer | FSX®/Histogram Flattening (IR only) | Can be | Yes/No | 7.5~14μm | Video stream 0: 640 x 480 pixels Video stream 1: 1,280 x 960 pixels Radiometric stream: 640 x 480 pixels | Normally 7ms | 1.1 | 30Hz | 1,280×960 | 640×480 | RTSP protocol to FLIR Atlas SDK | Can be | 0.15m (0.49ft) | 640×480 | For selected measurement functions, digital inputs, internal camera temperature, and timers. | Based on distance, atmospheric temperature, and relative humidity inputs | Maximum/minimum temperature value and position displayed in the box | Global object parameters. Local parameters per analytic function | Can be | -20℃~120℃ 0℃~650℃ 300℃~2,000℃ | ±2°C or ±2% error (relative to reading) when ambient temperature is 15°C to 35°C and measurement target temperature is above 0°C | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus | Can be | |
FLIR A500f Advanced Smart Sensor 80° |
Available upon quote | When the ambient temperature is between 15℃ and 35℃ and the temperature of the object exceeds 0℃, ±2℃ or ±2% of the measured value | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | 17μm | 5mm (0.19in) | - | RTSP protocol | Uncooled microbolometer | FSX®/Histogram Flattening (IR only) | Can be | Yes/No | 7.5~14μm | Video stream 0: 640 x 480 pixels, radiometric stream: 464 x 348 pixels | Normally 10ms | 1.3, 80° | - | 1,280×960 | 464×348 | RTSP protocol to FLIR Atlas SDK | - | 0.1m (3.9in) | - | For selected measurement functions, digital inputs, internal camera temperature, and timers. | Based on distance, atmospheric temperature, and relative humidity inputs | Display maximum/minimum temperature value and position in box | Global object parameters. Local parameters per analytic function | Can be | -20℃~120℃ 0℃~650℃ 300℃~1,500℃ | When the ambient temperature is between 15℃ and 35℃ and the temperature of the object exceeds 0℃, ±2℃ or ±2% of the measured value | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus | Can be | |
FLIR A700f Advanced Smart Sensor 80° |
Available upon quote | When the ambient temperature is between 15℃ and 35℃ and the temperature of the object exceeds 0℃, ±2℃ or ±2% of the measured value | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | 17μm | 5mm (0.19in) | - | RTSP protocol | Uncooled microbolometer | FSX®/Histogram Flattening (IR only) | Can be | Yes/No | 7.5~14μm | Video stream 0: 640 x 480 pixels, radiometric stream: 464 x 348 pixels | Normally 10ms | 1.3, 80° | - | 1,280×960 | 464×348 | RTSP protocol to FLIR Atlas SDK | - | 0.1m (3.9in) | - | For selected measurement functions, digital inputs, internal camera temperature, and timers. | Based on distance, atmospheric temperature, and relative humidity inputs | Display maximum/minimum temperature value and position in box | Global object parameters. Local parameters per analytic function | Can be | -20℃~120℃ 0℃~650℃ 300℃~1,500℃ | When the ambient temperature is between 15℃ and 35℃ and the temperature of the object exceeds 0℃, ±2℃ or ±2% of the measured value | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus | Can be |
Click on the part number for more information about each product