Product
Compatible with a wide range of power measurements from minute power to large power 149-10AHandling Company
Kikusui Electronics Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | AC voltage Maximum allowable input voltage | AC voltage accuracy | AC voltage measurement range | Accessories | DC voltage Maximum allowable input voltage | DC voltage accuracy | DC voltage measurement range | Display | Input resistance | Mass | Power consumption | Power supply | Size | Voltmeter model |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
149-10A |
Available upon quote |
11 kV rms (Sine Wave 50 ~ 60 Hz) Pulse: 15 kV peak |
± (1% rdg + 0.05% range) | 0.500~10.000kV |
High voltage test lead (TL05-TOS) x 1 High voltage cable (HTL-2.5DH) x 1 |
DC: ±14kV Pulse: 15 kV peak |
± (0.5% rdg + 0.03% range) | 0.500~10.000kV | LED, 7 segments | 1,000 MΩ ± 2% | Approximately 3 kg | Approximately 10VA | 100V ± 10%, 50/60Hz | 134 (140) W × 164 (190) H × 270 (350) Dmm () is the maximum part |
Double integral type AC is average value response, sine wave RMS value calibration 3 sampling/s |