PID insulation tester TOS7210SHandling Company
Kikusui Electronics Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Ammeter accuracy | Ammeter display | Ammeter measurement range | Ammeter measurement range AUTO | Ammeter measurement range FIX | Ammeter measurement range selection | Output section Maximum rated output | Output section Output rise time | Output section Output terminal Output format | Output section Output terminal Voltage to ground | Output section Output voltage Resolution | Output section Output voltage accuracy | Output section Output voltage range | Output section discharge function | Output section maximum rated current | Output section ripple 2,000V no load | Output section ripple maximum rated load | Output section short circuit current | Output section voltage fluctuation rate | Resistance meter | Resistance meter accuracy | Resistance meter display | Resistance meter hold function | Resistance meter measurement range | Resistance meter measurement range AUTO | Resistance meter measurement range FIX | Resistance meter measurement range selection | Voltmeter accuracy | Voltmeter measurement range | Voltmeter resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TOS7210S |
Available upon quote |
± (4% of reading +0.005μA) (i<10.00μA) ± (4% of reading +0.005μA) (10.00μA≦i<100.0μA) |
□.□□□μA (i<10.00μA) □□.□□μA (10.00μA≦i<100.0μA) □□□.□μA (100.0μA≦i<1,000μA) □□□□μA (1,000μA≦i) |
0.000μA~1,900μA | Automatically changes the current measurement range at any time according to the current measurement value | The current measurement range is fixed by the output voltage setting value and LOWER setting value (at W COMP OFF) | Current measurement range can be selected from AUTO or FIX | 2W (2,000V/1mA) | 50ms or less (10%~90%, no load) | Floating |
±1,000 Vdc (terminals whose polarity is set to positive) +1,000 Vdc and -3,000 Vdc (terminals with negative polarity) |
1V | ± (1.5% of setting +2V) | 50V~2,000V | Forced discharge at the end of the test (discharge resistance 20kΩ) | 1mA | 20Vp-p or less | 20Vp-p or less | 2mA or less (instantaneous 200mA or less) | 1% or less (maximum rated load → no load) | (i = output voltage measurement value/resistance measurement value) |
± (10% of reading) (100nA<i≦200nA) ± (5% of reading) (200nA<i≦1μA) |
□.□□MΩ ([R<10.0MΩ) □□.□MΩ (10.0MΩ≦R<100.0MΩ) □□□MΩ (100.0MΩ≦R<1,000MΩ) |
The resistance value at the end of the test is held during the PASS period. | 0.01MΩ~5,000MΩ (within a range exceeding 100nA and maximum rated current 1mA) | Automatically changes the current measurement range at any time according to the current value for resistance measurement | The current measurement range is fixed by the output voltage setting value and LOWER setting value (at W COMP OFF) | Current measurement range can be selected from AUTO or FIX | ± (1% of reading +1V) | 0V~2,400V | 1V |