Product
Insulation resistance tester TOS7200Handling Company
Kikusui Electronics Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Installation location | Insulation resistance | Nominal voltage range (allowable voltage range) | Operating range | Output section Output rise time | Output section Output terminal Output model | Output section Output terminal Voltage to ground | Output section Output voltage range | Output section Output voltage range Resolution | Output section Output voltage range Setting accuracy | Output section discharge function | Output section maximum rated current | Output section maximum rated load | Output section ripple 1,000 V no load | Output section ripple maximum rated load | Output section short circuit current | Output section voltage fluctuation rate | Permissible frequency range | Power consumption at rated load | Resistance meter accuracy | Resistance meter display | Resistance meter hold function | Resistance meter measurement range | Specification warranty range | Storage range | Voltmeter accuracy | Voltmeter measurement range | Voltmeter resolution | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TOS7200 |
Available upon quote | Indoors up to 2,000m altitude | 30MΩ or more (DC 500V) (AC LINE to chassis) | AC 100V~240V (AC 85V~250V) |
Temperature 0℃ ~40℃ Humidity 20%rh~80%rh (no condensation) |
50 ms or less (10~90%, no load) | Floating | ±1,000Vdc | −25 V~ −1,000 V | 1V | ± (1.5% of setting + 2V) | Forced discharge at the end of the test (discharge resistance 25kΩ) | 1mA | 1W (1,000V DC/1mA) | 2 Vp-p or less | 10 Vp-p or less | 12 mA or less | 1% or less (maximum rated load → no load) | 47Hz~63Hz | Max 30VA |
± (10 % of reading) (100 nA < i ≦ 200 nA) ± (5 % of reading) (200 nA < i ≦ 1 μA) |
□.□□MΩ (R < 10.0 MΩ) □□.□MΩ (10.0 MΩ≦ R <100.0 MΩ) □□□MΩ (100.0MΩ ≦ R <1000MΩ) |
The measured resistance value at the end of the test is held during the PASS period. |
Current measurement range can be selected from AUTO or FIX AUTO: Automatically change the current measurement range at any time according to the measured current value FIX: Fixed current measurement range by output voltage setting value and LOWER setting value (when UPPER OFF) |
Temperature 5℃ ~35℃ Humidity 20%rh~80%rh (no condensation) |
Temperature −20℃ ~70℃ Humidity 90% RH or less (no condensation) |
± (1% of reading + 1 V) | 0V~−1,200V | 1V | AC 1,390V for 2 minutes, 10mA or less (AC LINE to chassis) |