Product
A new standard for withstanding voltage and insulation resistance testing that can be used easily, safely and globally: Voltage and insulation resistance tester TOS5300 seriesHandling Company
Kikusui Electronics Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | AC output section Output method | AC output section Output setting range | AC output section Output voltage waveform Distortion rate | AC output section frequency | AC output section frequency accuracy | AC output section input voltage fluctuation | AC output section maximum rated current | AC output section maximum rated output | AC output section maximum rated voltage | AC output section output range | AC output section output setting accuracy | AC output section output setting resolution | AC output section output voltage waveform | AC output section short circuit current | AC output section transformer capacity | AC output section voltage fluctuation rate | DC output section Output setting range | DC output section discharge function | DC output section maximum rated current | DC output section maximum rated load | DC output section maximum rated output | DC output section maximum rated voltage | DC output section output range | DC output section output setting accuracy | DC output section output setting resolution | DC output section ripple (TYP value) 5kV no load | DC output section short circuit current (TYP value) | DC output section voltage fluctuation rate | Limit voltage value (Limit Voltage) | Start Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TOS5300 |
Available upon quote | PWM switching method | 0.00kV ~ 5.50kV | Output voltage 0.5 kV or more: 3% or less (at no load and with pure resistive load) | 50Hz/60Hz | ±0.5% (excluding during voltage rise) | ± 0.3 % (5 kV no load, power supply voltage 90 V ~ 250 V) | 100 mA (output voltage 0.5 kV or more) | 500VA (5kV/100mA) | 5 kV | 0.05 kV ~ 5.00 kV | ± (2 % of set + 20 V) (at no load) | 10V STEP | Sine wave | 200 mA or more (output voltage 1.0 kV or more) | 500VA | 10% or less (maximum rated load → no load) | - | - | - | - | - | - | - | - | - | - | - | - | Upper limit reference value for test voltage setting can be set AC: 0.00 kV ~ 5.50 kV, DC: 0.00 kV ~ 6.20 kV | The starting voltage during a withstanding voltage test can be set to 50% of the set voltage. | |
TOS5301 |
Available upon quote | PWM switching method | 0.00kV ~ 5.50kV | Output voltage 0.5 kV or more: 3% or less (at no load and with pure resistive load) | 50Hz/60Hz | ±0.5% (excluding during voltage rise) | ± 0.3 % (5 kV no load, power supply voltage 90 V ~ 250 V) | 100 mA (output voltage 0.5 kV or more) | 500VA (5kV/100mA) | 5 kV | 0.05 kV ~ 5.00 kV | ± (2 % of set + 20 V) (at no load) | 10V STEP | Sine wave | 200 mA or more (output voltage 1.0 kV or more) | 500VA | 10% or less (maximum rated load → no load) | 0.00 kV ~ 6.20 kV | Forced discharge at the end of the test (discharge resistance 125 kΩ) | 10mA | 100 Vp-p | 50W (5kV / 10mA) | 6kV | 0.05 kV ~ 6.00 kV | ± (2 % of set + 20 V) (at no load) | 10V STEP | 50 Vp-p | 40 mA (at 6 kV output) | 3% or less (maximum rated load → no load) | Upper limit reference value for test voltage setting can be set AC: 0.00 kV ~ 5.50 kV, DC: 0.00 kV ~ 6.20 kV | The starting voltage during a withstanding voltage test can be set to 50% of the set voltage. | |
TOS5302 |
Available upon quote | PWM switching method | 0.00kV ~ 5.50kV | Output voltage 0.5 kV or more: 3% or less (at no load and with pure resistive load) | 50Hz/60Hz | ±0.5% (excluding during voltage rise) | ± 0.3 % (5 kV no load, power supply voltage 90 V ~ 250 V) | 100 mA (output voltage 0.5 kV or more) | 500VA (5kV/100mA) | 5 kV | 0.05 kV ~ 5.00 kV | ± (2 % of set + 20 V) (at no load) | 10V STEP | Sine wave | 200 mA or more (output voltage 1.0 kV or more) | 500VA | 10% or less (maximum rated load → no load) | - | - | - | - | - | - | - | - | - | - | - | - | Upper limit reference value for test voltage setting can be set AC: 0.00 kV ~ 5.50 kV, DC: 0.00 kV ~ 6.20 kV | The starting voltage during a withstanding voltage test can be set to 50% of the set voltage. |
Click on the part number for more information about each product