Product
High reliability power supply PAN-A seriesHandling Company
Kikusui Electronics Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | About input voltage | Constant current operation display color | Constant current temperature coefficient | Constant voltage operation display color | Constant voltage temperature coefficient | Cooling method | Dimension type | Ground | Input power (approx. kVA) | Input voltage (V) | Insulation voltage | Load fluctuation CC (mA) | Load fluctuation CV (mV) | Mass kg (approx.) | Operating humidity range | Operating temperature range | Output CC (A) | Output CV (V) | Power supply fluctuation CC (mA) | Power supply fluctuation CV (mV) | Ripple CC (mArms) | Ripple CV (mVrms) | Ripple noise | Transient response time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PAN16-10A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | 0 | Possible to ground positive or negative terminal | 0.4 | 100 | AC1,500V for 1 minute No abnormality | 3 | 0.005%+2 | 11 | 10%~90%RH | 0~40℃ | 0~10 | 0~16 | 1 | 0.005%+2 | 2 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN16-18A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | Ⅰ | Possible to ground positive or negative terminal | 0.8 | 100 | AC1,500V for 1 minute No abnormality | 3 | 0.005%+1 | 17 | 10%~90%RH | 0~40℃ | 0~18 | 0~16 | 1 | 0.005%+1 | 5 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN16-30A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | Ⅰ | Possible to ground positive or negative terminal | 1.1 | 100 | AC1,500V for 1 minute No abnormality | 3 | 0.005%+2 | Twenty three | 10%~90%RH | 0~40℃ | 0~30 | 0~16 | 3 | 0.005%+1 | 5 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN16-50A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | II | Possible to ground positive or negative terminal | 1.6 | 100 | AC1,500V for 1 minute No abnormality | 5 | 0.005%+2 | 36 | 10%~90%RH | 0~40℃ | 0~50 | 0~16 | 3 | 0.005%+1 | 10 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN35-5A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | 0 | Possible to ground positive or negative terminal | 0.4 | 100 | AC1,500V for 1 minute No abnormality | 2 | 0.005%+1 | 11 | 10%~90%RH | 0~40℃ | 0~5 | 0~35 | 1 | 0.005%+1 | 1 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN35-10A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | Ⅰ | Possible to ground positive or negative terminal | 0.8 | 100 | AC1,500V for 1 minute No abnormality | 3 | 0.005%+1 | 17 | 10%~90%RH | 0~40℃ | 0~10 | 0~35 | 1 | 0.005%+1 | 2 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN35-20A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | Ⅰ | Possible to ground positive or negative terminal | 1.4 | 100 | AC1,500V for 1 minute No abnormality | 3 | 0.005%+2 | Twenty three | 10%~90%RH | 0~40℃ | 0~20 | 0~35 | 3 | 0.005%+1 | 3 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN35-30A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | II | Possible to ground positive or negative terminal | 1.8 | 100 | AC1,500V for 1 minute No abnormality | 5 | 0.005%+1 | 36 | 10%~90%RH | 0~40℃ | 0~30 | 0~35 | 3 | 0.005%+1 | 5 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN60-3A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | 0 | Possible to ground positive or negative terminal | 0.35 | 100 | AC1,500V for 1 minute No abnormality | 2 | 0.005%+1 | 11 | 10%~90%RH | 0~40℃ | 0~3 | 0~60 | 2 | 0.005%+1 | 1 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current | |
PAN60-6A |
Available upon quote | All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) | Displayed with red LED | 300p.p.m./℃ (standard value) | Displayed with green LED | 100p.p.m./℃ (standard value) | Forced air cooling by fan | Ⅰ | Possible to ground positive or negative terminal | 0.7 | 100 | AC1,500V for 1 minute No abnormality | 3 | 0.005%+1 | 17 | 10%~90%RH | 0~40℃ | 0~6 | 0~60 | 3 | 0.005%+1 | 2 | 0.5 | 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output | 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current |
Click on the part number for more information about each product