High reliability power supply PAN-A series-PAN16-10A
High reliability power supply PAN-A series-Kikusui Electronics Co., Ltd.

High reliability power supply PAN-A series
Kikusui Electronics Co., Ltd.


About This Product

The PAN-A series is a high performance, highly reliable variable DC stabilized power supply that can be used in all fields from research and development and quality control to production sites. This series consists of a pre-regulator using an FET and a series regulator using a power transistor. Therefore, it combines the high-quality output characteristics that are a feature of series control type, and the highly efficient input characteristics with low power harmonic distortion that is a feature of choke input type phase control. On the other hand, in terms of reliability and safety, which are important for power supplies, we use components with sufficient derating and utilize the mounting technology we have cultivated over many years. In addition, all models are equipped with various safety features such as overvoltage protection devices. Features ■Low temperature drift We have achieved low temperature drift of 100ppm/℃ (constant voltage characteristics) and 300ppm/℃ (constant current characteristics) by selecting the parts used, improving the circuit, and designing heat dissipation using forced air cooling. ■Fast transient response The wideband error amplifier has stable frequency-gain/phase characteristics and loop gain up to high frequencies, so it has a low output impedance and can adequately respond to sudden changes. Standard value: 50μs ■Application Equipped with various functions to support system upgrades, such as remote control using analog signals or a computer (GPIB), remote sensing, and one-control series and parallel operation. PAN350-3.5A/PAN600-2A cannot be operated in series. ■Computer control By connecting the power supply controller PIA4800 series to the PAN-A series, computer control via GPIB or RS232C is possible. ■Output on/off control Output on/off can be controlled using external contact signals. ■One-control parallel operation - The current capacity can be increased by connecting the same models in parallel. Output control can be performed with one main unit (master). - When performing remote sensing, remote control, output on/off, etc., please use only one main unit. *Other model numbers are available.

  • Product

    High reliability power supply PAN-A series

Share this product


600+ people viewing

Last viewed: 1 hour ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of High reliability power supply PAN-A series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) About input voltage Constant current operation display color Constant current temperature coefficient Constant voltage operation display color Constant voltage temperature coefficient Cooling method Dimension type Ground Input power (approx. kVA) Input voltage (V) Insulation voltage Load fluctuation CC (mA) Load fluctuation CV (mV) Mass kg (approx.) Operating humidity range Operating temperature range Output CC (A) Output CV (V) Power supply fluctuation CC (mA) Power supply fluctuation CV (mV) Ripple CC (mArms) Ripple CV (mVrms) Ripple noise Transient response time
High reliability power supply PAN-A series-Part Number-PAN16-10A

PAN16-10A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan 0 Possible to ground positive or negative terminal 0.4 100 AC1,500V for 1 minute No abnormality 3 0.005%+2 11 10%~90%RH 0~40℃ 0~10 0~16 1 0.005%+2 2 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN16-18A

PAN16-18A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan Possible to ground positive or negative terminal 0.8 100 AC1,500V for 1 minute No abnormality 3 0.005%+1 17 10%~90%RH 0~40℃ 0~18 0~16 1 0.005%+1 5 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN16-30A

PAN16-30A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan Possible to ground positive or negative terminal 1.1 100 AC1,500V for 1 minute No abnormality 3 0.005%+2 Twenty three 10%~90%RH 0~40℃ 0~30 0~16 3 0.005%+1 5 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN16-50A

PAN16-50A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan II Possible to ground positive or negative terminal 1.6 100 AC1,500V for 1 minute No abnormality 5 0.005%+2 36 10%~90%RH 0~40℃ 0~50 0~16 3 0.005%+1 10 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN35-5A

PAN35-5A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan 0 Possible to ground positive or negative terminal 0.4 100 AC1,500V for 1 minute No abnormality 2 0.005%+1 11 10%~90%RH 0~40℃ 0~5 0~35 1 0.005%+1 1 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN35-10A

PAN35-10A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan Possible to ground positive or negative terminal 0.8 100 AC1,500V for 1 minute No abnormality 3 0.005%+1 17 10%~90%RH 0~40℃ 0~10 0~35 1 0.005%+1 2 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN35-20A

PAN35-20A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan Possible to ground positive or negative terminal 1.4 100 AC1,500V for 1 minute No abnormality 3 0.005%+2 Twenty three 10%~90%RH 0~40℃ 0~20 0~35 3 0.005%+1 3 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN35-30A

PAN35-30A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan II Possible to ground positive or negative terminal 1.8 100 AC1,500V for 1 minute No abnormality 5 0.005%+1 36 10%~90%RH 0~40℃ 0~30 0~35 3 0.005%+1 5 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN60-3A

PAN60-3A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan 0 Possible to ground positive or negative terminal 0.35 100 AC1,500V for 1 minute No abnormality 2 0.005%+1 11 10%~90%RH 0~40℃ 0~3 0~60 2 0.005%+1 1 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current
High reliability power supply PAN-A series-Part Number-PAN60-6A

PAN60-6A

Available upon quote All shipments will be 100V as indicated. If you require a power supply voltage other than 100V, please contact us when placing your order. (factory option) Displayed with red LED 300p.p.m./℃ (standard value) Displayed with green LED 100p.p.m./℃ (standard value) Forced air cooling by fan Possible to ground positive or negative terminal 0.7 100 AC1,500V for 1 minute No abnormality 3 0.005%+1 17 10%~90%RH 0~40℃ 0~6 0~60 3 0.005%+1 2 0.5 5Hz to 1MHz, ±3dB band, AC voltage type with average value indication and effective value indication, measured by grounding either the positive or negative output 50μs: Time for the output voltage to return to within 0.05% of the rated value + 10mV for a 5% to 100% fluctuation in the output current

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kikusui Electronics Co., Ltd.


View more products of Kikusui Electronics Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree