High efficiency large capacity switching power supply PAT-T series-PAT20-200T
High efficiency large capacity switching power supply PAT-T series-Kikusui Electronics Co., Ltd.

High efficiency large capacity switching power supply PAT-T series
Kikusui Electronics Co., Ltd.


About This Product

The PAT-T series is a constant voltage/constant current automatic switching type switching DC power supply. By adopting a soft switching method, we aim to improve efficiency and reduce noise, and by making full use of high-density mounting technology, we have achieved a significant reduction in size and weight. Equipped with a "power factor correction circuit" that is unusual for this class, it not only improves the power supply environment (suppresses harmonic current), but also greatly contributes to "energy conservation" by simplifying and downsizing power distribution equipment and reducing power consumption. . Furthermore, by optimizing the heat dissipation design, we have achieved a guaranteed operating temperature of 50°C. It can also be used in harsh environments such as continuous full-load operation at high temperatures. The operation/display panel has a simple and intuitive design for ease of viewing and use, while considering control by a computer or sequencer, it is equipped with an RS-232C interface in addition to external analog control, monitor output, and status output. Standard equipment. Also supports USB, GPIB, and LAN (LXI) interfaces as options. It can be used both stand-alone and as part of a test system. Features ・Achieved output capacity starting from 100 yen per 1W ・Space-saving and easy to use ・Can be used vertically (optional) ・Soft switching method ・Supports parallel operation of up to 5 units (same model) ・4kW type can also operate with single-phase 200V input ・CV, CC priority start function ・External analog control function ・High current model (smart rack system) ■Other functions ・RS-232C is standard equipment ・USB/GPIB/LAN compatible (factory option) ・Output ON/OFF delay function for peace of mind during sequence operation, etc. ・Memory function (3 sets of voltage/current) ・Voltage/current monitor output ・Status signal output ・Remote sensing function ・Protective function equipment ・High noise resistance (safe for car electronics related tests, etc.) ・High maintainability such as easy fan replacement *Other model numbers are available.

  • Product

    High efficiency large capacity switching power supply PAT-T series

Share this product


750+ people viewing

Last viewed: 11 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of High efficiency large capacity switching power supply PAT-T series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Constant current Maximum settable current Constant current load fluctuation Constant current power fluctuation Constant current ripple noise Constant current setting accuracy Constant current temperature coefficient Constant voltage Maximum settable voltage Constant voltage fall time Constant voltage load fluctuation Constant voltage power fluctuation Constant voltage ripple noise Constant voltage rise time Constant voltage setting accuracy Constant voltage temperature coefficient Constant voltage transient response Current display Maximum display Current display accuracy Efficiency Input current Input power Input voltage range/input frequency range Inrush current Nominal input rated voltage OUTPUT ON/OFF delay Power factor Rated Rated output current Rating Rated output power Rating Rated output voltage Voltage display accuracy Voltage display maximum display
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT20-200T

PAT20-200T

Available upon quote 105% of rating×75% (for single-phase input) /105% of rating (for three-phase input) ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 400 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 100 mVp-p in measurement frequency band 10 Hz to 20 MHz
10 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (when load current suddenly changes from 50% to 100%) 999.9 ± (0.5% of reading+5 digits) at 23℃±5℃ 84% (min) Single-phase 22 A (max) (at 3 kW load) / Three-phase 17 A (max) (at rated load) Single-phase 4 kVA (max) (at 3 kW load) / Three-phase 5 kVA (max) (at rated load) 180V~250V ・47Hz~63Hz 50A peak (max) Single phase/three phase AC200 V~AC240 V 50 Hz~60 Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200 V, at rated load) 200.0A 4 kW (in three-phase input mode) /3 kW (in single-phase input mode) 20.00V ± (0.2% of reading+5 digits) at 23℃±5℃ 99.99
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT40-100T

PAT40-100T

Available upon quote 105% of rating×75% (for single-phase input) /105% of rating (for three-phase input) ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 300 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 300 mVp-p in measurement frequency band 10 Hz~20 MHz
30 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (when load current suddenly changes from 50% to 100%) 999.9 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200 V, at rated load) Single-phase 22 A (max) (at 3 kW load) / Three-phase 17 A (max) (at rated load) Single-phase 4 kVA (max) (at 3 kW load) / Three-phase 5 kVA (max) (at rated load) 180V~250V ・47Hz~63Hz 50A peak (max) Single phase/three phase AC200 V~AC240 V 50 Hz~60 Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200 V, at rated load) 100.0A 4 kW (in three-phase input mode) /3 kW (in single-phase input mode) 40.00V ± (0.2% of reading+5 digits) at 23℃±5℃ 99.99
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT60-67T

PAT60-67T

Available upon quote 105% of rating×75% (for single-phase input) /105% of rating (for three-phase input) ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 250 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 350 mVp-p in measurement frequency band 10 Hz~20 MHz
30 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (when load current suddenly changes from 50% to 100%) 99.99 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200 V, at rated load) Single-phase 22 A (max) (at 3 kW load) / Three-phase 17 A (max) (at rated load) Single-phase 4 kVA (max) (at 3 kW load) / Three-phase 5 kVA (max) (at rated load) 180V~250V ・47Hz~63Hz 50A peak (max) Single phase/three phase AC200 V~AC240 V 50 Hz~60 Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200 V, at rated load) 67.00A 4 kW (in three-phase input mode) /3 kW (in single-phase input mode) 60.00V ± (0.2% of reading+5 digits) at 23℃±5℃ 99.99
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT160-25T

PAT160-25T

Available upon quote 105% of rating×75% (for single-phase input) /105% of rating (for three-phase input) ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 200 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 350 mVp-p in measurement frequency band 10 Hz~20 MHz
30 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (when load current suddenly changes from 50% to 100%) 99.99 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200 V, at rated load) Single-phase 22 A (max) (at 3 kW load) / Three-phase 17 A (max) (at rated load) Single-phase 4 kVA (max) (at 3 kW load) / Three-phase 5 kVA (max) (at rated load) 180V~250V ・47Hz~63Hz 50A peak (max) Single phase/three phase AC200 V~AC240 V 50 Hz~60 Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200 V, at rated load) 25.00A 4 kW (in three-phase input mode) /3 kW (in single-phase input mode) 160.0V ± (0.2% of reading+5 digits) at 23℃±5℃ 999.9
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT20-400T

PAT20-400T

Available upon quote 105% of rating ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 500 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 100 mVp-p in measurement frequency band 10 Hz to 20 MHz
10 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) 999.9 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200V, at rated load) 32 A (max) (at rated load) 10 kVA (max) 180V~250V ・47Hz~63Hz 100 Apeak (max) 3 phase AC200V~AC240V 50Hz~60Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200V, at rated load) 400.0 A 8kW 20.00V ± (0.2% of reading+5 digits) at 23℃±5℃ 99.99
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT30-266T

PAT30-266T

Available upon quote 105% of rating ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 400 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 300 mVp-p in measurement frequency band 10 Hz~20 MHz
20 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) 999.9 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200V, at rated load) 32 A (max) (at rated load) 10 kVA (max) 180V~250V ・47Hz~63Hz 100 Apeak (max) 3 phase AC200V~AC240V 50Hz~60Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200V, at rated load) 266.0A 8kW 30.00V ± (0.2% of reading+5 digits) at 23℃±5℃ 99.99
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT40-200T

PAT40-200T

Available upon quote 105% of rating ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 400 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 300 mVp-p in measurement frequency band 10 Hz~20 MHz
30 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) 999.9 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200V, at rated load) 32 A (max) (at rated load) 10 kVA (max) 180V~250V ・47Hz~63Hz 100 Apeak (max) 3 phase AC200V~AC240V 50Hz~60Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200V, at rated load) 200.0A 8kW 40.00V ± (0.2% of reading+5 digits) at 23℃±5℃ 99.99
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT60-133T

PAT60-133T

Available upon quote 105% of rating ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 350 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 350 mVp-p in measurement frequency band 10 Hz~20 MHz
30 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) 999.9 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200V, at rated load) 32 A (max) (at rated load) 10 kVA (max) 180V~250V ・47Hz~63Hz 100 Apeak (max) 3 phase AC200V~AC240V 50Hz~60Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200V, at rated load) 133.0A 8kW 60.00V ± (0.2% of reading+5 digits) at 23℃±5℃ 99.99
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT80-100T

PAT80-100T

Available upon quote 105% of rating ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 300 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 350 mVp-p in measurement frequency band 10 Hz~20 MHz
30 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) 999.9 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200V, at rated load) 32 A (max) (at rated load) 10 kVA (max) 180V~250V ・47Hz~63Hz 100 Apeak (max) 3 phase AC200V~AC240V 50Hz~60Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200V, at rated load) 100.0A 8kW 80.00V ± (0.2% of reading+5 digits) at 23℃±5℃ 99.99
High efficiency large capacity switching power supply PAT-T series-Part Number-PAT160-50T

PAT160-50T

Available upon quote 105% of rating ± (0.2% of rating +30 mA) ± (0.1% of rating +30 mA) 200 mArms ± (0.5% of rating +50 mA) 200 ppm/℃ (typ) (with external analog control) 105% of rating 100 ms (rated load) / 2,000 ms (no load) ± (0.1% of rating+5 mV) ± (0.05% of rating+5 mV) 350 mVp-p in measurement frequency band 10 Hz~20 MHz
30 mVrms in measurement frequency band 5 Hz to 1 MHz
100 ms (rated load) /100 ms (no load) ± (0.2% of rating +50 mV) 100 ppm/℃ (max) (with external analog control) 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) 999.9 ± (0.5% of reading+5 digits) at 23℃±5℃ 85% (min) (input voltage AC200V, at rated load) 32 A (max) (at rated load) 10 kVA (max) 180V~250V ・47Hz~63Hz 100 Apeak (max) 3 phase AC200V~AC240V 50Hz~60Hz OFF. 0.1 s~10.0 s (resolution 0.1 s) 0.95 (typ) (input voltage AC200V, at rated load) 50.0A 8kW 160.0V ± (0.2% of reading+5 digits) at 23℃±5℃ 999.9

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kikusui Electronics Co., Ltd.


View more products of Kikusui Electronics Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree