Product
High efficiency large capacity switching power supply PAT-T seriesHandling Company
Kikusui Electronics Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Constant current Maximum settable current | Constant current load fluctuation | Constant current power fluctuation | Constant current ripple noise | Constant current setting accuracy | Constant current temperature coefficient | Constant voltage Maximum settable voltage | Constant voltage fall time | Constant voltage load fluctuation | Constant voltage power fluctuation | Constant voltage ripple noise | Constant voltage rise time | Constant voltage setting accuracy | Constant voltage temperature coefficient | Constant voltage transient response | Current display Maximum display | Current display accuracy | Efficiency | Input current | Input power | Input voltage range/input frequency range | Inrush current | Nominal input rated voltage | OUTPUT ON/OFF delay | Power factor | Rated Rated output current | Rating Rated output power | Rating Rated output voltage | Voltage display accuracy | Voltage display maximum display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PAT20-200T |
Available upon quote | 105% of rating×75% (for single-phase input) /105% of rating (for three-phase input) | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 400 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
100 mVp-p in measurement frequency band 10 Hz to 20 MHz 10 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (when load current suddenly changes from 50% to 100%) | 999.9 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 84% (min) | Single-phase 22 A (max) (at 3 kW load) / Three-phase 17 A (max) (at rated load) | Single-phase 4 kVA (max) (at 3 kW load) / Three-phase 5 kVA (max) (at rated load) | 180V~250V ・47Hz~63Hz | 50A peak (max) | Single phase/three phase AC200 V~AC240 V 50 Hz~60 Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200 V, at rated load) | 200.0A | 4 kW (in three-phase input mode) /3 kW (in single-phase input mode) | 20.00V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 99.99 | |
PAT40-100T |
Available upon quote | 105% of rating×75% (for single-phase input) /105% of rating (for three-phase input) | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 300 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
300 mVp-p in measurement frequency band 10 Hz~20 MHz 30 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (when load current suddenly changes from 50% to 100%) | 999.9 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200 V, at rated load) | Single-phase 22 A (max) (at 3 kW load) / Three-phase 17 A (max) (at rated load) | Single-phase 4 kVA (max) (at 3 kW load) / Three-phase 5 kVA (max) (at rated load) | 180V~250V ・47Hz~63Hz | 50A peak (max) | Single phase/three phase AC200 V~AC240 V 50 Hz~60 Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200 V, at rated load) | 100.0A | 4 kW (in three-phase input mode) /3 kW (in single-phase input mode) | 40.00V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 99.99 | |
PAT60-67T |
Available upon quote | 105% of rating×75% (for single-phase input) /105% of rating (for three-phase input) | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 250 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
350 mVp-p in measurement frequency band 10 Hz~20 MHz 30 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (when load current suddenly changes from 50% to 100%) | 99.99 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200 V, at rated load) | Single-phase 22 A (max) (at 3 kW load) / Three-phase 17 A (max) (at rated load) | Single-phase 4 kVA (max) (at 3 kW load) / Three-phase 5 kVA (max) (at rated load) | 180V~250V ・47Hz~63Hz | 50A peak (max) | Single phase/three phase AC200 V~AC240 V 50 Hz~60 Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200 V, at rated load) | 67.00A | 4 kW (in three-phase input mode) /3 kW (in single-phase input mode) | 60.00V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 99.99 | |
PAT160-25T |
Available upon quote | 105% of rating×75% (for single-phase input) /105% of rating (for three-phase input) | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 200 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
350 mVp-p in measurement frequency band 10 Hz~20 MHz 30 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (when load current suddenly changes from 50% to 100%) | 99.99 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200 V, at rated load) | Single-phase 22 A (max) (at 3 kW load) / Three-phase 17 A (max) (at rated load) | Single-phase 4 kVA (max) (at 3 kW load) / Three-phase 5 kVA (max) (at rated load) | 180V~250V ・47Hz~63Hz | 50A peak (max) | Single phase/three phase AC200 V~AC240 V 50 Hz~60 Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200 V, at rated load) | 25.00A | 4 kW (in three-phase input mode) /3 kW (in single-phase input mode) | 160.0V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 999.9 | |
PAT20-400T |
Available upon quote | 105% of rating | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 500 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
100 mVp-p in measurement frequency band 10 Hz to 20 MHz 10 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) | 999.9 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200V, at rated load) | 32 A (max) (at rated load) | 10 kVA (max) | 180V~250V ・47Hz~63Hz | 100 Apeak (max) | 3 phase AC200V~AC240V 50Hz~60Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200V, at rated load) | 400.0 A | 8kW | 20.00V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 99.99 | |
PAT30-266T |
Available upon quote | 105% of rating | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 400 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
300 mVp-p in measurement frequency band 10 Hz~20 MHz 20 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) | 999.9 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200V, at rated load) | 32 A (max) (at rated load) | 10 kVA (max) | 180V~250V ・47Hz~63Hz | 100 Apeak (max) | 3 phase AC200V~AC240V 50Hz~60Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200V, at rated load) | 266.0A | 8kW | 30.00V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 99.99 | |
PAT40-200T |
Available upon quote | 105% of rating | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 400 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
300 mVp-p in measurement frequency band 10 Hz~20 MHz 30 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) | 999.9 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200V, at rated load) | 32 A (max) (at rated load) | 10 kVA (max) | 180V~250V ・47Hz~63Hz | 100 Apeak (max) | 3 phase AC200V~AC240V 50Hz~60Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200V, at rated load) | 200.0A | 8kW | 40.00V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 99.99 | |
PAT60-133T |
Available upon quote | 105% of rating | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 350 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
350 mVp-p in measurement frequency band 10 Hz~20 MHz 30 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) | 999.9 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200V, at rated load) | 32 A (max) (at rated load) | 10 kVA (max) | 180V~250V ・47Hz~63Hz | 100 Apeak (max) | 3 phase AC200V~AC240V 50Hz~60Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200V, at rated load) | 133.0A | 8kW | 60.00V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 99.99 | |
PAT80-100T |
Available upon quote | 105% of rating | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 300 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
350 mVp-p in measurement frequency band 10 Hz~20 MHz 30 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) | 999.9 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200V, at rated load) | 32 A (max) (at rated load) | 10 kVA (max) | 180V~250V ・47Hz~63Hz | 100 Apeak (max) | 3 phase AC200V~AC240V 50Hz~60Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200V, at rated load) | 100.0A | 8kW | 80.00V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 99.99 | |
PAT160-50T |
Available upon quote | 105% of rating | ± (0.2% of rating +30 mA) | ± (0.1% of rating +30 mA) | 200 mArms | ± (0.5% of rating +50 mA) | 200 ppm/℃ (typ) (with external analog control) | 105% of rating | 100 ms (rated load) / 2,000 ms (no load) | ± (0.1% of rating+5 mV) | ± (0.05% of rating+5 mV) |
350 mVp-p in measurement frequency band 10 Hz~20 MHz 30 mVrms in measurement frequency band 5 Hz to 1 MHz |
100 ms (rated load) /100 ms (no load) | ± (0.2% of rating +50 mV) | 100 ppm/℃ (max) (with external analog control) | 5 ms (When sensing at the output terminal when the load current suddenly changes from 50% to 100%) | 999.9 | ± (0.5% of reading+5 digits) at 23℃±5℃ | 85% (min) (input voltage AC200V, at rated load) | 32 A (max) (at rated load) | 10 kVA (max) | 180V~250V ・47Hz~63Hz | 100 Apeak (max) | 3 phase AC200V~AC240V 50Hz~60Hz | OFF. 0.1 s~10.0 s (resolution 0.1 s) | 0.95 (typ) (input voltage AC200V, at rated load) | 50.0A | 8kW | 160.0V | ± (0.2% of reading+5 digits) at 23℃±5℃ | 999.9 |
Click on the part number for more information about each product