Product
Digital indicator TD-98AHandling Company
Tokyo Measuring Instruments Laboratory Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | A/D converter effective resolution | A/D converter speed | Analog filter | Applicable gauge resistance | Balance adjustment method | Bridge power supply | Calibration method | Calibration value selection | Comparison function | Display | Equivalent input calibration (error range ±0.1% FS) | External dimensions | External input | External output | Hold function | Interface | Mass | Measurement target | Measuring range | Monitor output (load resistance 2kΩ or more) | Nonlinearity | Number of measurement points | Operating temperature and humidity range | Panel cut dimensions | Power supply | Sensitivity stability | Storage temperature and humidity range | Zero stability |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TD-98A |
Available upon quote |
・Approx. 1/15,000 for 6.0mV/V input (at bridge power supply DC2.5V) ・About 1/30,000 for 3.0mV/V input (at bridge power supply DC10V) |
2,000 times/second | Select from 30Hz, 100Hz, 300Hz, 1kHz | 87.5~350Ω | By digital calculation | Select from DC2.5V, 10V (output current within 120mA) | Equivalent input calibration, actual load calibration | Can store and switch between 4 types of calibration values | Upper upper limit (HH), lower lower limit (LL), OK, upper limit (HI), lower limit (LO) | 3.5 inch TFT color LCD module (display area 71 x 53 mm) 320 x 240 dots |
・0.5mV/V~6.0mV/V (at bridge power supply DC2.5V) ・0.5mV/V~3.0mV/V (at bridge power supply DC10V) |
96 (W) × 96 (H) × 138 (D) mm | Work selection input, hold control input, digital zero input, graph drawing control input, calibration value selection input | Upper and lower limit comparison output, normal operation output, hold completion output, graph drawing completion output, open collector output | Sample hold, peak hold, bottom hold, peak-to-peak hold, average value hold, inflection point hold, local maximum hold, local minimum hold, extreme value difference hold | RS-232C, asynchronous, baud rate 9,600bps~57,600bps | Approximately 1.0kg | Strain gauge type transducer (87.5~350Ω) |
・±6.0mV/V (at bridge power supply DC2.5V) ・±3.0mV/V (at bridge power supply DC10V) ・Maximum display ±99,999 |
・Approx. 0.5V per 1mV/V input (at bridge power supply DC2.5V) ・Approx. 2V per 1mV/V input (at bridge power supply DC10V) |
Within 0.02%FS±1digit (at 3.0mV/V input) | 1 point | -10℃~+40℃, 85%RH or less (excluding condensation) | 92×92^+1^-0mm (Plate thickness: 1.6~3.2mm) | DC24V (±15%) | Within 0.01%/℃ | -20℃~+60℃, 85%RH or less (excluding condensation) | Within 0.5μV/℃ RTI |