Product
IXARC Absolute Encoder OCD-CAA1BHandling Company
POSITAL -FrabaItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Axial diameter | EMC: Noise Immediate | Electromagnetic interference | Flange material | Flango | Friction torque | Housing coating | Housing material | Humidity | Impact resistance | Inertial rotor inertia | Interface cycle time | Maximum axial load | Maximum machine speed | Mttf | Operating temperature | Output driver | Over -voltage prevention | Polar Improvement | Profile | Programming function | Protection structure (housing) | Protection structure (shaft) | Shaft type | Supply voltage | Transmission speed | Turn -on time | Vibration resistance | interface | power consumption |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OCD-CAA1B-1413-S12V-2AW |
Available upon quote | ø 12 mm (0.47 ") | Din en 61000-6-2 | Din en 61000-6-4 | Stainless steel V2A (1.4305; 303) | Synchro Frange, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | No paint | Stainless steel (V2A) (1.4305, 303) | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial load 50 n, radius direction load 50 N | ≤ 3,000 1/min | 13.5 years (40 ° C) | -40 ℃ Fixed (-40 ° f), -30 ℃ Flexible (-22 ° F) -+85 ° C (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Middle real axis, one -sided hand removal l = 20mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-1213-B12V-2AW |
Available upon quote | ø 12 mm (0.47 ") | Din en 61000-6-2 | Din en 61000-6-4 | Stainless steel V2A (1.4305; 303) | One -side hollow shaft, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | No paint | Stainless steel (V2A) (1.4305, 303) | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | - | ≤ 3,000 1/min | 13.5 years (40 ° C) | -40 ℃ Fixed (-40 ° f), -30 ℃ Flexible (-22 ° F) -+85 ° C (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Makura hole depth = 30mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-1416-C10V-5AW |
Available upon quote | ø 10 mm (0.39 ") | Din en 61000-6-2 | Din en 61000-6-4 | Stainless steel V2A (1.4305; 303) | Clamping flange, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | No paint | Stainless steel (V2A) (1.4305, 303) | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 3,000 1/min | 13.5 years (40 ° C) | -40 ℃ Fixed (-40 ° f), -30 ℃ Flexible (-22 ° F) -+85 ° C (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Middle real axis, one -sided hand removal l = 20mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-1416-SA1A-PA9 |
Available upon quote | ø 6 mm (0.24 ") | Din en 61000-6-2 | Din en 61000-6-4 | Aluminum | Synchro Frange, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | Cathedematic prevention (> 720 hours salt water spray resistance) + liquid painting | steel | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 12,000 1/min | 13.5 years (40 ° C) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP54 | IP65 | Both the interior axis of the axis l = 10mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-1213-B08A-PA9 |
Available upon quote | ø 12 mm (0.47 ") | Din en 61000-6-2 | Din en 61000-6-4 | Stainless steel V2A (1.4305; 303) | Synchro Frange, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | No paint | Stainless steel (V2A) (1.4305, 303) | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial load 50 n, radius direction load 50 N | ≤ 3,000 1/min | 13.5 years (40 ° C) | -40 ℃ Fixed (-40 ° f), -30 ℃ Flexible (-22 ° F) -+85 ° C (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Middle real axis, one -sided hand removal l = 20mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-0013-B15S-H72 |
Available upon quote | ø 15 mm (0.59 ") | Din en 61000-6-2 | Din en 61000-6-4 | Aluminum | One -side hollow shaft, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | Cathedemonic protection (> 720 hours salt water spray resistance) | steel | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | - | ≤ 3,000 1/min | 13.5 years (40 ° C) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Makura hole depth = 30mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-0012-B15S-H2M |
Available upon quote | ø 15 mm (0.59 ") | Din en 61000-6-2 | Din en 61000-6-4 | Aluminum | One -side hollow shaft, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | Cathedemonic protection (> 720 hours salt water spray resistance) | steel | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | - | ≤ 3,000 1/min | 13.5 years (40 ° C) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Makura hole depth = 30mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-0012-SA10-H2M |
Available upon quote | ø 6 mm (0.24 ") | Din en 61000-6-2 | Din en 61000-6-4 | Aluminum | Synchro Frange, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | Cathedemonic protection (> 720 hours salt water spray resistance) | steel | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 12,000 1/min | 13.5 years (40 ° C) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP65 | IP65 | Both the interior axis of the axis l = 10mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-1416-B12V-H3P |
Available upon quote | ø 12 mm (0.47 ") | Din en 61000-6-2 | Din en 61000-6-4 | Stainless steel V2A (1.4305; 303) | One -side hollow shaft, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | No paint | steel | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | - | ≤ 3,000 1/min | 13.5 years (40 ° C) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Makura hole depth = 30mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w | |
OCD-CAA1B-0012-S06V-H2M |
Available upon quote | ø 6 mm (0.24 ") | Din en 61000-6-2 | Din en 61000-6-4 | Stainless steel V2A (1.4305; 303) | Synchro Frange, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | No paint | Stainless steel (V2A) (1.4305, 303) | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 3,000 1/min | 13.5 years (40 ° C) | - +85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP68/IP69K | IP66/IP67 | Middle real axis L = 10mm | 10 - 30 VDC | Minimum 20 k bore rate, up to 1 m bore rate | <1 s | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 2.5 w |
Click on the part number for more information about each product