About This Product

◾️A abundant assortment of Absolute rotary encoder Absolute rotary encoder can provide a unique position value from the moment you turn on the power. The movement that occurs while the power of the system is turned off is converted to an accurate position when the encoder is turned on again. Another advantage is its abundant variations. Absolute encoder can select a single turn, multi -turn, different resolution, communication interface, etc. Users can also select according to needs from thousands of mechanical and connection configurations. ◾️Main variation The motion control is diverse, from factory automation to mobile machine control systems. This application has its own characteristics, but it requires accurate and real -time information on the physical position of the machine device. Posital's Abtalute Encoder Series is designed to deal with all issues facing customers. ◾️Fangi and shaft options ・ Real axis and hollow shaft ・ Multiple flange design that conforms to all applications ・ Coupling, tethers and adapters are available ◾️ Application The IXARC Absolute Encoder always realizes reliable positions and does not require relative values, increasing the safety and efficiency of machinery. There are other model numbers.

  • Product

    IXARC Absolute Encoder OCD-CAA1B




*Please note that we may not be able to accommodate sample requests.

10 Models of IXARC Absolute Encoder OCD-CAA1B

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Axial diameter EMC: Noise Immediate Electromagnetic interference Flange material Flango Friction torque Housing coating Housing material Humidity Impact resistance Inertial rotor inertia Interface cycle time Maximum axial load Maximum machine speed Mttf Operating temperature Output driver Over -voltage prevention Polar Improvement Profile Programming function Protection structure (housing) Protection structure (shaft) Shaft type Supply voltage Transmission speed Turn -on time Vibration resistance interface power consumption
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-1413-S12V-2AW

OCD-CAA1B-1413-S12V-2AW

Available upon quote ø 12 mm (0.47 ") Din en 61000-6-2 Din en 61000-6-4 Stainless steel V2A (1.4305; 303) Synchro Frange, ø 58 mm ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) No paint Stainless steel (V2A) (1.4305, 303) 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS Axial load 50 n, radius direction load 50 N ≤ 3,000 1/min 13.5 years (40 ° C) -40 ℃ Fixed (-40 ° f), -30 ℃ Flexible (-22 ° F) -+85 ° C (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP66/IP67 IP66/IP67 Middle real axis, one -sided hand removal l = 20mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-1213-B12V-2AW

OCD-CAA1B-1213-B12V-2AW

Available upon quote ø 12 mm (0.47 ") Din en 61000-6-2 Din en 61000-6-4 Stainless steel V2A (1.4305; 303) One -side hollow shaft, ø 58 mm ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) No paint Stainless steel (V2A) (1.4305, 303) 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS - ≤ 3,000 1/min 13.5 years (40 ° C) -40 ℃ Fixed (-40 ° f), -30 ℃ Flexible (-22 ° F) -+85 ° C (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP66/IP67 IP66/IP67 Makura hole depth = 30mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-1416-C10V-5AW

OCD-CAA1B-1416-C10V-5AW

Available upon quote ø 10 mm (0.39 ") Din en 61000-6-2 Din en 61000-6-4 Stainless steel V2A (1.4305; 303) Clamping flange, ø 58 mm ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) No paint Stainless steel (V2A) (1.4305, 303) 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS Axial loading load 40 N, radius direction load 110 n ≤ 3,000 1/min 13.5 years (40 ° C) -40 ℃ Fixed (-40 ° f), -30 ℃ Flexible (-22 ° F) -+85 ° C (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP66/IP67 IP66/IP67 Middle real axis, one -sided hand removal l = 20mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-1416-SA1A-PA9

OCD-CAA1B-1416-SA1A-PA9

Available upon quote ø 6 mm (0.24 ") Din en 61000-6-2 Din en 61000-6-4 Aluminum Synchro Frange, ø 58 mm ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) Cathedematic prevention (> 720 hours salt water spray resistance) + liquid painting steel 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS Axial loading load 40 N, radius direction load 110 n ≤ 12,000 1/min 13.5 years (40 ° C) -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP54 IP65 Both the interior axis of the axis l = 10mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-1213-B08A-PA9

OCD-CAA1B-1213-B08A-PA9

Available upon quote ø 12 mm (0.47 ") Din en 61000-6-2 Din en 61000-6-4 Stainless steel V2A (1.4305; 303) Synchro Frange, ø 58 mm ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) No paint Stainless steel (V2A) (1.4305, 303) 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS Axial load 50 n, radius direction load 50 N ≤ 3,000 1/min 13.5 years (40 ° C) -40 ℃ Fixed (-40 ° f), -30 ℃ Flexible (-22 ° F) -+85 ° C (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP66/IP67 IP66/IP67 Middle real axis, one -sided hand removal l = 20mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-0013-B15S-H72

OCD-CAA1B-0013-B15S-H72

Available upon quote ø 15 mm (0.59 ") Din en 61000-6-2 Din en 61000-6-4 Aluminum One -side hollow shaft, ø 58 mm ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) Cathedemonic protection (> 720 hours salt water spray resistance) steel 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS - ≤ 3,000 1/min 13.5 years (40 ° C) -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP66/IP67 IP66/IP67 Makura hole depth = 30mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-0012-B15S-H2M

OCD-CAA1B-0012-B15S-H2M

Available upon quote ø 15 mm (0.59 ") Din en 61000-6-2 Din en 61000-6-4 Aluminum One -side hollow shaft, ø 58 mm ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) Cathedemonic protection (> 720 hours salt water spray resistance) steel 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS - ≤ 3,000 1/min 13.5 years (40 ° C) -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP66/IP67 IP66/IP67 Makura hole depth = 30mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-0012-SA10-H2M

OCD-CAA1B-0012-SA10-H2M

Available upon quote ø 6 mm (0.24 ") Din en 61000-6-2 Din en 61000-6-4 Aluminum Synchro Frange, ø 58 mm ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) Cathedemonic protection (> 720 hours salt water spray resistance) steel 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS Axial loading load 40 N, radius direction load 110 n ≤ 12,000 1/min 13.5 years (40 ° C) -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP65 IP65 Both the interior axis of the axis l = 10mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-1416-B12V-H3P

OCD-CAA1B-1416-B12V-H3P

Available upon quote ø 12 mm (0.47 ") Din en 61000-6-2 Din en 61000-6-4 Stainless steel V2A (1.4305; 303) One -side hollow shaft, ø 58 mm ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) No paint steel 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS - ≤ 3,000 1/min 13.5 years (40 ° C) -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP66/IP67 IP66/IP67 Makura hole depth = 30mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w
IXARC Absolute Encoder OCD-CAA1B-Part Number-OCD-CAA1B-0012-S06V-H2M

OCD-CAA1B-0012-S06V-H2M

Available upon quote ø 6 mm (0.24 ") Din en 61000-6-2 Din en 61000-6-4 Stainless steel V2A (1.4305; 303) Synchro Frange, ø 58 mm ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) No paint Stainless steel (V2A) (1.4305, 303) 98%, no condensation ≤ 100 g (Half Sign 6 MS, EN 60068-27) ≤ 30 GCM² [≤ 0.17 OZ-IN²] ≥ 1 MS Axial loading load 40 N, radius direction load 110 n ≤ 3,000 1/min 13.5 years (40 ° C) - +85 ℃ (+185 ° F) Transiver (ISO11898), (Galvanic insulation via optocapula) Existence Existence DS-406 Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode IP68/IP69K IP66/IP67 Middle real axis L = 10mm 10 - 30 VDC Minimum 20 k bore rate, up to 1 m bore rate <1 s ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) Canopen ≤ 2.5 w

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of POSITAL -Fraba


View more products of POSITAL -Fraba

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree