Product
IXARC Absolute Encoder TCR-CA01BHandling Company
POSITAL -FrabaItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Axial diameter | EMC: Noise Immediate | Electromagnetic interference | Flange material | Flango | Friction torque | Housing coating | Housing material | Humidity | Impact resistance | Inertial rotor inertia | Interface cycle time | Maximum axial load | Maximum machine speed | Mttf | Operating temperature | Output driver | Over -voltage prevention | Polar Improvement | Profile | Programming function | Protection structure (housing) | Protection structure (shaft) | Shaft type | Supply voltage | Technology | Transmission speed | Vibration resistance | interface | power consumption |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TCR-CA01B-1416-SA10-PRX |
Available upon quote | ø 6 mm (0.24 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | Synchro Frange, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 12,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | - +85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP65 | IP65 | Both the interior axis of the axis l = 10mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1416-B12S-PAX |
Available upon quote | ø 12 mm (0.47 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | One -side hollow shaft, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | - | ≤ 3,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Makura hole depth = 30mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1416-SB90-PRK |
Available upon quote | ø 10 mm (0.39 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | Synchro Frange, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 12,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP65 | IP65 | Middle real axis, one -sided hand removal l = 20mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1216-C060-PRK |
Available upon quote | ø 6 mm (0.24 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | Clamping flange, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 12,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP65 | IP65 | Middle real axis L = 10mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1213-C10S-PRX |
Available upon quote | ø 10 mm (0.39 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | Clamping flange, ø 58 mm | ≤ 5 NCM @ 20 ° C, (7.1 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 3,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP66/IP67 | Middle real axis, one -sided hand removal l = 20mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 20 g (20 hz-2,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1416-B120-PRK |
Available upon quote | ø 12 mm (0.47 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | One -side hollow shaft, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | - | ≤ 12,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP65 | IP65 | Makura hole depth = 30mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1216-B150-PAK |
Available upon quote | ø 15 mm (0.59 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | One -side hollow shaft, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | - | ≤ 12,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP65 | IP65 | Makura hole depth = 30mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1413-C100-PRX |
Available upon quote | ø 10 mm (0.39 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | Clamping flange, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 12,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP66/IP67 | IP65 | Middle real axis, one -sided hand removal l = 20mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1416-C120-PRK |
Available upon quote | ø 12 mm (0.47 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | Clamping flange, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | Axial loading load 40 N, radius direction load 110 n | ≤ 12,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP65 | IP65 | Middle real axis, one -sided hand removal l = 20mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W | |
TCR-CA01B-1213-B120-PRK |
Available upon quote | ø 12 mm (0.47 ") |
EN 61000-6-2 En 61326-3-2 & EN 61000-6-7 |
Din en 61000-6-4 | Aluminum | One -side hollow shaft, ø 58 mm | ≤ 3 NCM @ 20 ℃ (4.2 OZ-in @ 68 ° f) | No paint | aluminum | 98%, no condensation | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ≤ 30 GCM² [≤ 0.17 OZ-IN²] | ≥ 1 MS | - | ≤ 12,000 1/min | 100 YEARS @ 40 ° C (Based on en ISO 13849-1) | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Transiver (ISO11898), (Galvanic insulation via optocapula) | Existence | Existence | DS-406 | Resolution, preset, 2 limit switches, 8 CAMS, Borate, CAN-identifier, bootloader, communication mode: Polling polling, cycle mode, synchro mode | IP65 | IP65 | Makura hole depth = 30mm | 10 - 30 VDC | Optical + Magnetic | Minimum 20 k bore rate, up to 1 m bore rate | ≤ 10 g (10 Hz-1,000 Hz, en 60068-2-6) | Canopen | ≤ 3.7 W |
Click on the part number for more information about each product