Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change-CORA 5001 Direct
Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change-Anton Paar GmbH

Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change
Anton Paar GmbH


About This Product

■ Raman -specific meter suitable for quick and reliable identification of substances based on chemical fingerprints and monitoring chemical changes -You can analyze the Fiber models that can be analyzed outside the device using the probe or the sample in a sealed compartment, and select a super -safe Direct model that has acquired laser class 1 authentication. ・ CORA 5001 minimizes the training required for operation by the guided analysis procedure. This desktop type laman -shaped optical meter has a battery option in a space -saving space, so it can be used for multiple purposes in the analysis operations in -house and on -site. ■ Main functions ・ Easy and safe - user guidance and laser class 1 ・ No sample before treatment -accessories that increase efficiency ・ In a nutshell, various samples are measured with one unit ・ Pharmaceutical company Compliance -Anton Pearl SPECTROSCOPY SUITE ・ Autofocus -the strongest signal that achieves reproducible results ■ Related products CORA100

  • Product

    Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change

Share this product


270+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Battery (optional) Battery drive time Countermeasive time two wavelengths Data Export format Data port Detector array single wavelength Detector array two wavelengths Dimensions (depth x width x height) Exciting wavelength single wavelength Exciting wavelength two wavelengths Fiber probe dimensions Incilence time single wavelength Input Power Internal storage capacity Laser class Laser output Laser output single wavelength Power consumption Range of operating Resolution (ASTM E2529 compliant) Resolution (ASTM E2529 compliant) single wavelength Security Spectral area Spectral area single wavelength Spectroscope Spectrum library Wavelength proofreading Wireless connection display weight
Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change-Part Number-CORA 5001 Direct

CORA 5001 Direct

Available upon quote lithium ion > 1.5h 0.005 S ~ 600 S (532 NM and 785 nm), 0.001 S ~ 20 S (1,064 Nm) .csv, .txt, .png, .spc, .aps, .pdf 4 X USB 2.0, 1 x Ethernet, 1 x CAN output, 1 x USB (PC connection) 2,048 PX CCD
2,048 PX CCD
256 PX INGAAS
2,048 PX CCD (532 NM and 785 nm), 256 PX ingaas (1,064 NM) 355 x 384 x 168mm 532nm
785nm
1,064nm
532nm, 785nm
532nm, 1,064nm
785nm, 1,064nm
Cable length: 1.50m 0.005 S ~ 600 S
0.005 S ~ 600 S
0.001 S ~ 20 S
Line power input: AC 115/230V, 50/60Hz
In -vehicle power adapter input: DC 9 ~ 32V
8 1 50mW (532nm) 0 ~ 450mW (785nm and 1,064Nm) (sample) 50 MW (laser rays)
0 MW ~ 450 MW (adjustable) (sample)
0 MW ~ 450 MW (adjustable) (sample)
Inline power input: Up to 100 VA
DC input: Representative value 30 VA (60 VA when optional battery charging)
10 ℃ ~ 35 ° C (without condensation) 9 ~ 12cm-1 (532nm) 6 ~ 9cm-1 (785nm) 12 ~ 17cm-1 (1,064Nm) 9 ~ 12cm-1
6 ~ 9cm-1
12-17cm-1
User roll, user password login with customizable authority 9 ~ 12cm-1 (532nm) 6 ~ 9cm-1 (785nm) 12 ~ 17cm-1 (1,064Nm) 200 ~ 3,500cm-1
100 ~ 2,300cm-1
100 ~ 2,300cm-1
F/2, transmitted body accumulation posterity (VPG) Factory library, user construction, options made by other companies Automatic school film by software Wi-Fi stick (optional) 10 inch touch screen 9.8
Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change-Part Number-CORA 5001 Fiber

CORA 5001 Fiber

Available upon quote lithium ion > 1.5h 0.005 S ~ 600 S (532 NM and 785 nm), 0.001 S ~ 20 S (1,064 Nm) .csv, .txt, .png, .spc, .aps, .pdf 4 X USB 2.0, 1 x Ethernet, 1 x CAN output, 1 x USB (PC connection) 2,048 PX CCD
2,048 PX CCD
256 PX INGAAS
2,048 PX CCD (532 NM and 785 nm), 256 PX ingaas (1,064 NM) 355 x 384 x 168mm 532nm
785nm
1,064nm
532nm, 785nm
532nm, 1,064nm
785nm, 1,064nm
Cable length: 1.50m 0.005 S ~ 600 S
0.005 S ~ 600 S
0.001 S ~ 20 S
Line power input: AC 115/230V, 50/60Hz
In -vehicle power adapter input: DC 9 ~ 32V
8 3B 50mW (532nm) 0 ~ 450mW (785nm and 1,064Nm) (sample) 50 MW (laser rays)
0 MW ~ 450 MW (adjustable) (sample)
0 MW ~ 450 MW (adjustable) (sample)
Inline power input: Up to 100 VA
DC input: Representative value 30 VA (60 VA when optional battery charging)
10 ℃ ~ 35 ° C (without condensation) 9 ~ 12cm-1 (532nm) 6 ~ 9cm-1 (785nm) 12 ~ 17cm-1 (1,064Nm) 9 ~ 12cm-1
6 ~ 9cm-1
12-17cm-1
User roll, user password login with customizable authority 9 ~ 12cm-1 (532nm) 6 ~ 9cm-1 (785nm) 12 ~ 17cm-1 (1,064Nm) 200 ~ 3,500cm-1
100 ~ 2,300cm-1
100 ~ 2,300cm-1
F/2, transmitted body accumulation posterity (VPG) Factory library, user construction, options made by other companies Automatic school film by software Wi-Fi stick (optional) 10 inch touch screen 9.8
Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change-Part Number-CORA 5001 Direct model for pharmaceuticals

CORA 5001 Direct model for pharmaceuticals

Available upon quote lithium ion > 1.5h 0.005 S ~ 600 S (532 NM and 785 nm), 0.001 S ~ 20 S (1,064 Nm) .csv, .txt, .png, .spc, .aps, .pdf 4 X USB 2.0, 1 x Ethernet, 1 x CAN output, 1 x USB (PC connection) 2,048 PX CCD
2,048 PX CCD
256 PX INGAAS
2,048 PX CCD (532 NM and 785 nm), 256 PX ingaas (1,064 NM) 355 x 384 x 168mm 532nm
785nm
1,064nm
532nm, 785nm
532nm, 1,064nm
785nm, 1,064nm
Cable length: 1.50m 0.005 S ~ 600 S
0.005 S ~ 600 S
0.001 S ~ 20 S
Line power input: AC 115/230V, 50/60Hz
In -vehicle power adapter input: DC 9 ~ 32V
8 1 50mW (532nm) 0 ~ 450mW (785nm and 1,064Nm) (sample) 50 MW (laser rays)
0 MW ~ 450 MW (adjustable) (sample)
0 MW ~ 450 MW (adjustable) (sample)
Inline power input: Up to 100 VA
DC input: Representative value 30 VA (60 VA when optional battery charging)
10 ℃ ~ 35 ° C (without condensation) 9 ~ 12cm-1 (532nm) 6 ~ 9cm-1 (785nm) 12 ~ 17cm-1 (1,064Nm) 9 ~ 12cm-1
6 ~ 9cm-1
12-17cm-1
User roll, user password login with customizable authority 9 ~ 12cm-1 (532nm) 6 ~ 9cm-1 (785nm) 12 ~ 17cm-1 (1,064Nm) 200 ~ 3,500cm-1
100 ~ 2,300cm-1
100 ~ 2,300cm-1
F/2, transmitted body accumulation posterity (VPG) Factory library, user construction, options made by other companies Automatic school film by software Wi-Fi stick (optional) 10 inch touch screen 9.8
Raman -specific optical meter CORA 5001 that is perfect for monitoring chemical change-Part Number-CORA 5001 Fiber model for pharmaceuticals

CORA 5001 Fiber model for pharmaceuticals

Available upon quote lithium ion > 1.5h 0.005 S ~ 600 S (532 NM and 785 nm), 0.001 S ~ 20 S (1,064 Nm) .csv, .txt, .png, .spc, .aps, .pdf 4 X USB 2.0, 1 x Ethernet, 1 x CAN output, 1 x USB (PC connection) 2,048 PX CCD
2,048 PX CCD
256 PX INGAAS
2,048 PX CCD (532 NM and 785 nm), 256 PX ingaas (1,064 NM) 355 x 384 x 168mm 532nm
785nm
1,064nm
532nm, 785nm
532nm, 1,064nm
785nm, 1,064nm
Cable length: 1.50m 0.005 S ~ 600 S
0.005 S ~ 600 S
0.001 S ~ 20 S
Line power input: AC 115/230V, 50/60Hz
In -vehicle power adapter input: DC 9 ~ 32V
8 3B 50mW (532nm) 0 ~ 450mW (785nm and 1,064Nm) (sample) 50 MW (laser rays)
0 MW ~ 450 MW (adjustable) (sample)
0 MW ~ 450 MW (adjustable) (sample)
Inline power input: Up to 100 VA
DC input: Representative value 30 VA (60 VA when optional battery charging)
10 ℃ ~ 35 ° C (without condensation) 9 ~ 12cm-1 (532nm) 6 ~ 9cm-1 (785nm) 12 ~ 17cm-1 (1,064Nm) 9 ~ 12cm-1
6 ~ 9cm-1
12-17cm-1
User roll, user password login with customizable authority 9 ~ 12cm-1 (532nm) 6 ~ 9cm-1 (785nm) 12 ~ 17cm-1 (1,064Nm) 200 ~ 3,500cm-1
100 ~ 2,300cm-1
100 ~ 2,300cm-1
F/2, transmitted body accumulation posterity (VPG) Factory library, user construction, options made by other companies Automatic school film by software Wi-Fi stick (optional) 10 inch touch screen 9.8

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Anton Paar GmbH


View more products of Anton Paar GmbH

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree