Clamp-on-type ultrasonic flow meter FU-ES series-FU-ES015
Clamp-on-type ultrasonic flow meter FU-ES series-Krone Co., Ltd.

Clamp-on-type ultrasonic flow meter FU-ES series
Krone Co., Ltd.


About This Product

■ Product features -The FU-ES series ultrasonic flow meter does not require input settings such as piping information, which are essential for setting, and is installed in the piping and then clicked to complete the settings. ・ Because it uses a special gasket pad, there is no need to apply a sensor gel. ・ Installation to the piping can be easily installed in just three steps, and efficiency is improved. ■ Applications Water treatment facility flow management, building test run and maintenance, agricultural irrigation water, etc.

  • Product

    Clamp-on-type ultrasonic flow meter FU-ES series




*Please note that we may not be able to accommodate sample requests.

8 Models of Clamp-on-type ultrasonic flow meter FU-ES series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Adaptive fluid Adaptive outer diameter Connection diameter Display cycle Display resolution ability Environmental temperature Flow range (L/min) Flow speed range Measurement accuracy Operating temperature Output signal Piping material Power-supply voltage Protection grade weight
Clamp-on-type ultrasonic flow meter FU-ES series-Part Number-FU-ES015

FU-ES015

Available upon quote Liquid without impurities and air bubbles 21 ~ 22 mm 1/2 "(15A) 0.5 seconds / 1 second 0.0001 -10 ~ 60 ° C (35-85 % RH) * No condensation 1.5 ~ 120 ± 0.3 ~ 6.0 m/s (recommended), ± 0.1 ~ 10 m/s (measured) ± 3.0 % RD (10 % or more of F.S) /± 0.3 % F.S. (less than 10 % of F.S.) 0 to 85 ℃ 4-20 MA analog output / modbus RTU RS485 Metal assignment, resin piping (UPVC / PPH / PVDF / PFA / PTFE) 12 ~ 36VDC (current consumption: 200ma @12V) IP66 770
Clamp-on-type ultrasonic flow meter FU-ES series-Part Number-FU-ES020

FU-ES020

Available upon quote Liquid without impurities and air bubbles 25 ~ 27.2 mm 3/4 "(20A) 0.5 seconds / 1 second 0.0001 -10 ~ 60 ° C (35-85 % RH) * No condensation 2.0 ~ 200 ± 0.3 ~ 6.0 m/s (recommended), ± 0.1 ~ 10 m/s (measured) ± 3.0 % RD (10 % or more of F.S) /± 0.3 % F.S. (less than 10 % of F.S.) 0 to 85 ℃ 4-20 MA analog output / modbus RTU RS485 Metal assignment, resin piping (UPVC / PPH / PVDF / PFA / PTFE) 12 ~ 36VDC (current consumption: 200ma @12V) IP66 770
Clamp-on-type ultrasonic flow meter FU-ES series-Part Number-FU-ES025

FU-ES025

Available upon quote Liquid without impurities and air bubbles 32 ~ 34 mm 1 "(25A) 0.5 seconds / 1 second 0.0001 -10 ~ 60 ° C (35-85 % RH) * No condensation 3.0 ~ 300 ± 0.3 ~ 6.0 m/s (recommended), ± 0.1 ~ 10 m/s (measured) ± 3.0 % RD (10 % or more of F.S) /± 0.3 % F.S. (less than 10 % of F.S.) 0 to 85 ℃ 4-20 MA analog output / modbus RTU RS485 Metal assignment, resin piping (UPVC / PPH / PVDF / PFA / PTFE) 12 ~ 36VDC (current consumption: 200ma @12V) IP66 785
Clamp-on-type ultrasonic flow meter FU-ES series-Part Number-FU-ES032

FU-ES032

Available upon quote Liquid without impurities and air bubbles 38 ~ 42.16 mm 1.1/4 "(32a) 0.5 seconds / 1 second 0.0001 -10 ~ 60 ° C (35-85 % RH) * No condensation 5.0 ~ 470 ± 0.3 ~ 6.0 m/s (recommended), ± 0.1 ~ 10 m/s (measured) ± 3.0 % RD (10 % or more of F.S) /± 0.3 % F.S. (less than 10 % of F.S.) 0 to 85 ℃ 4-20 MA analog output / modbus RTU RS485 Metal assignment, resin piping (UPVC / PPH / PVDF / PFA / PTFE) 12 ~ 36VDC (current consumption: 200ma @12V) IP66 800
Clamp-on-type ultrasonic flow meter FU-ES series-Part Number-FU-ES040

FU-ES040

Available upon quote Liquid without impurities and air bubbles 48 ~ 50 mm 1.1/2 "(40A) 0.5 seconds / 1 second 0.0001 -10 ~ 60 ° C (35-85 % RH) * No condensation 8.0 ~ 770 ± 0.3 ~ 6.0 m/s (recommended), ± 0.1 ~ 10 m/s (measured) ± 3.0 % RD (10 % or more of F.S) /± 0.3 % F.S. (less than 10 % of F.S.) 0 to 85 ℃ 4-20 MA analog output / modbus RTU RS485 Metal assignment, resin piping (UPVC / PPH / PVDF / PFA / PTFE) 12 ~ 36VDC (current consumption: 200ma @12V) IP66 -
Clamp-on-type ultrasonic flow meter FU-ES series-Part Number-FU-ES050

FU-ES050

Available upon quote Liquid without impurities and air bubbles 60 ~ 63 mm 2 "(50A) 0.5 seconds / 1 second 0.0001 -10 ~ 60 ° C (35-85 % RH) * No condensation 13.0 ~ 1,320 ± 0.3 ~ 6.0 m/s (recommended), ± 0.1 ~ 10 m/s (measured) ± 3.0 % RD (10 % or more of F.S) /± 0.3 % F.S. (less than 10 % of F.S.) 0 to 85 ℃ 4-20 MA analog output / modbus RTU RS485 Metal assignment, resin piping (UPVC / PPH / PVDF / PFA / PTFE) 12 ~ 36VDC (current consumption: 200ma @12V) IP66 -
Clamp-on-type ultrasonic flow meter FU-ES series-Part Number-FU-ES065

FU-ES065

Available upon quote Liquid without impurities and air bubbles 73 ~ 76.3 mm 2.1/2 "(65A) 0.5 seconds / 1 second 0.0001 -10 ~ 60 ° C (35-85 % RH) * No condensation 22.0 ~ 1,670 ± 0.3 ~ 6.0 m/s (recommended), ± 0.1 ~ 10 m/s (measured) ± 3.0 % RD (10 % or more of F.S) /± 0.3 % F.S. (less than 10 % of F.S.) 0 to 85 ℃ 4-20 MA analog output / modbus RTU RS485 Metal assignment, resin piping (UPVC / PPH / PVDF / PFA / PTFE) 12 ~ 36VDC (current consumption: 200ma @12V) IP66 -
Clamp-on-type ultrasonic flow meter FU-ES series-Part Number-FU-ES080

FU-ES080

Available upon quote Liquid without impurities and air bubbles 88.9 ~ 90 mm 3 "(80A) 0.5 seconds / 1 second 0.0001 -10 ~ 60 ° C (35-85 % RH) * No condensation 30.0 ~ 1,870 ± 0.3 ~ 6.0 m/s (recommended), ± 0.1 ~ 10 m/s (measured) ± 3.0 % RD (10 % or more of F.S) /± 0.3 % F.S. (less than 10 % of F.S.) 0 to 85 ℃ 4-20 MA analog output / modbus RTU RS485 Metal assignment, resin piping (UPVC / PPH / PVDF / PFA / PTFE) 12 ~ 36VDC (current consumption: 200ma @12V) IP66 -

Click on the part number for more information about each product