■ Overview ・ It is a signal/spectrum analyzer with excellent dynamic range, phase noise, amplitude accuracy, and measuring speed. ・ High -sensitivity spectrum analyzer, standard power measurement component, IQ analyzer, vector signal analyzer, real -time spectrum analyzer, transgent analyzer, pulse signal analyzer, audio analyzer, analog recovery measurement, phase miscellaneous measurement, noise index, etc. With We can provide customers with high -performance high -performance measurement services. ・ Excellent expandability and can further improve its performance by combining options. -The output interface of various digital and analog signals allows the spectral analyzer to establish or obtain secondary development. ・ It can be widely used to measure signals and devices in the fields such as aviation, aerospace, radar detection, communication, electronic counter major and operation. ■ Functions / features ・ Axis frequency range: up to 67GHz ・ Up to 550MHz analysis bandwidth ・ Excellent measurement performance and reception performance ・ Comprehensive spectral analysis function ・ Abundant measurement and applied function ・ Streaming and regenerative analysis functions of powerful RF signals ・ Flexible analog signal output interface ■ Overall performance evaluation of electronic systems ・ It is widely used for comprehensive evaluation of electronic systems such as radar and communication, and provides high -sensitivity, wide dynamic range, high accuracy, and high -efficiency solutions. ■ Measurement / diagnosis of transmitter ・ It has functions such as spectral analysis, one -button measurement, instantaneous analysis, analog recovery analysis, pulse signal analysis, and phase mixed sound measurement, and it is possible to comprehensively diagnose transmission and receiving machines. ・ It is used directly to integrate ATE and provides signal output, data output and results analysis for the system. ・ Electromagnetic signal RF streaming application: It can be applied to data collection and records in the process of a large -scale weapon test and the electromagnetic spectrum environment of the universe.

  • Product

    Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed




*Please note that we may not be able to accommodate sample requests.

9 Models of Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Control bandwidth External dimensions Frequency count accuracy Frequency range AC bond Frequency range DC bond Frequency reading accuracy Input connector Remaining response (the input end is connected to a match road, 0db attenuation) Reverse FM Signal analysis band width Sweep time range Temperature range Trace detector Trigger source Video bandwidth memory power consumption power supply span weight
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-4051A

4051A

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 4GHz 3Hz ~ 4GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) Type N (female), impedance. 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-4051B

4051B

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 9GHz 3Hz ~ 9GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) Type N (female), impedance. 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-4051c

4051c

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 13.2GHz 3Hz ~ 13.2GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) Type N (female), impedance. 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-4051D

4051D

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 18GHz 3Hz ~ 18GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) Type N (female), impedance. 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-4051E

4051E

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 26.5GHz 3Hz ~ 26.5GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) 3.5mm (male), impedance. 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-405F

405F

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 40GHz 3Hz ~ 40GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) 2.4mm (male), impedance: 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-4051G

4051G

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 45GHz 3Hz ~ 45GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) 2.4mm (male), impedance: 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-4051H

4051H

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 50GHz 3Hz ~ 50GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) 2.4mm (male), impedance: 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz 4051-H98: AC 100 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)
Signal/Spectrum Analyzer 4051 Series with excellent dynamic range, phase noise, amplitude accuracy, and measurement speed-Part Number-4051L

4051L

Available upon quote Range 1Hz ~ 3MHz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz conversion uncertainty: ± 0.3db 1Hz ~ 10MHz ± 1.0db 20MHz Width x height x depth = 510mm x 190mm x 534mm (including handle, footpad, bottom leg) width x height x depth = 426mm x 177mm x 460mm (excluding handle, footpad, bottom leg) ± (frequency reading accuracy x frequency standard accuracy + 0.1Hz) 10MHz ~ 67GHz 3Hz ~ 67GHz ± (frequency reading value × frequency reference accuracy + 0.1%frequency band + 5%resolution range + 2Hz + 0.5 horizontal resolution *) *horizontal resolution = span / (number-1) 1.85mm (male), impedance: 50Ω Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 10Hz ~ 10MHz (standard), 40MHz (optional), 200MHz (optional), 550MHz (optional) Span ≥ 10Hz: 1ms ~ 6000s Span = 0Hz: 1us ~ 6000s Operation temperature 0 ° C ~ +50 ° C, storage temperature: -40 ° C ~ +70 ° C Free, line, video, external level (front panel), external level (back panel), burst RF, timer Free, line, video, external level (front panel), external level (back panel), burst RF, timer 1Hz ~ 3MHz (1, 2, 3, 5 steps) 4, 5, 6, 8, 10, 20MHz (rated value) 4GB At the time of standby: 20W or less, operation: 400w or less Standard AC 220 ~ 240V: 50 ~ 60Hz Range: 0Hz (zero span), 10Hz ~ Maximum frequency accuracy of models: ± (0.1%x span + span / (number-1)) Approximately 25kg (if the configuration is different, the weight is different)