DC earth leakage relay LDI-1-LDI-1
DC earth leakage relay LDI-1-Hikari Shoko Co., Ltd.

DC earth leakage relay LDI-1
Hikari Shoko Co., Ltd.


About This Product

■Features ・Can protect DC ungrounded circuits of 750V DC or less. - Sensitivity setting is a 3-point sliding switch (10-15-20mA). ・The operating time is a 2-point sliding switch (0.5-1s). ・The return method is automatic/manual switching type. ・The control power supply is 100V DC and 100V AC. ・Earth leakage inspection can be easily performed by code display. - Environmentally friendly product (compliant with European RoHS Directive). ・ZCT supports load current of 800A or less. ■Operation LDI-1 provides earth leakage protection in DC circuits and is used in combination with a zero-phase current transformer with the same serial number. LDI-1 constantly applies an excitation signal to the secondary terminal of the zero-phase current transformer. When a leakage occurs in the electrical circuit, a DC leakage current is generated. Depending on the magnitude of the DC magnetic field generated in the zero-phase current transformer, the microcomputer calculates the DC leakage current from the excitation current controlled by the LDI-1, and sets the set value. Performs a comparison operation. When the operation point is reached by calculation, the operation display and output contact are activated. ■Function ・Measurement display When a zero-phase current transformer is connected and the power is turned on, it enters the monitoring state and displays the current DC leakage current value (Io) on the measurement display. K→L earth leakage is displayed without a sign, and L→K earth leakage is displayed with an unsign. If it is less than 1mA, it will be displayed as 0mA, and if it is more than 30mA, it will be displayed blinking at 30mA. (Measurement range: 1mA to 30mA) ・Operation and recovery When the DC leakage current reaches the set sensitivity current setting value and the operating time has elapsed, the operation indicator lights up and the output contact operates. The current value displayed is the current value. When the manual reset is set, pressing the reset switch will turn off the operation indicator light and reset the output contact. When set to automatic reset, the operation indicator light turns off and the output contact automatically resets when the current leakage disappears. ■Features ・This is a relay that detects leakage in DC ungrounded electrical circuits. ・You can check the current value and maximum value using the measurement display function. ・Used in combination with dedicated ZCT, BM30D/41D/64D.

  • Product

    DC earth leakage relay LDI-1

Share this product


20+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of DC earth leakage relay LDI-1

Product Image Part Number Price (excluding tax) Abnormal display Commercial frequency withstand voltage Control power range used Control power supply Electrical circuit used Exterior color Insulation resistance Lightning impulse withstand voltage Mass Measurement display Earth leakage current value/accuracy/resolution 1 Measurement display Earth leakage current value/accuracy/resolution 2 Measuring range Non-operating power consumption Number of monitoring circuits Operating power consumption Operating temperature range Operating time Operating time tolerance Operation display Output contact configuration Output contact switching capacity (cosφ=1) Recovery method Operation display Return method Contact Sensitivity current setting value Sensitivity current tolerance range Startup display Test display Test method
DC earth leakage relay LDI-1-Part Number-LDI-1

LDI-1

Available upon quote E_* flashes on the measurement display (display E_1 sensor not connected, E_2 control signal abnormal) AC2,000V for 1 minute between all electrical circuits and outer box
AC1,500V for 1 minute Between all P1, P2 and other terminals / Between all contacts and other terminals
AC1,000V for 1 minute between a1 and c1
DC80~140V
AC80~110V 50/60Hz
DC100V, AC100V 50/60Hz DC ungrounded circuit of 750V DC or less Black (ABS resin) 20MΩ or more with DC500V megger
Between all electrical circuits and the outer box, between all P1, P2 and other terminals/between all contacts and other terminals, between a1 and c1
7kV waveform (1.2φs/50φs), positive and negative 3 times each
Between P1, P2 collectively and outer box
Approximately 0.3kg 0mA is displayed when the measured value is within ±1mA
When the measured value is within 30mA, 30mA flashes.
-30mA blinks when the measured value is less than -30mA
1.0mA~9.9mA ±20%rdg±10digit 0.1mA
10mA~ ±20%rdg±1digit 1mA
1mA~30mA 2.0W or less (DC100V), 4.2VA or less (AC100V 50Hz) 1 circuit 2.4W or less (DC100V), 4.8VA or less (AC100V 50Hz) -10℃~+50℃ 0.5-1s 0.5s: 0.3~0.6s, 1s: 0.8~01.2s (signal 130% applied)
0.5s: 0.2~0.6s, 1s: 0.7~01.2s (signal 400% applied)
Light emitting diode display (red) 1 pair of A contacts DC30V 5A
AC100V 3A
AC200V 2A
Automatic/manual Automatic/manual 10-15-20mA ±20% of the rated sensitivity current setting value LDI-1 PG200_*.**.**" is displayed on the measurement display. All measurement display lights up Test switch