Two-stage alarm earth leakage relay LEG-193L series-LEG-193L
Two-stage alarm earth leakage relay LEG-193L series-Hikari Shoko Co., Ltd.

Two-stage alarm earth leakage relay LEG-193L series
Hikari Shoko Co., Ltd.


About This Product

■JIS C 8374 earth leakage relay (earth leakage relay) standard compliant product This product is a relay that cuts off the electrical circuit or issues an alarm in the event of an electrical leakage accident in the low-voltage electrical circuit. ■Features ・The inside of the relay has a plug-in structure. - Highly noise resistant, with the ability to be unaffected by radio waves, surges, etc. - Stable operation under changes in voltage, frequency, temperature, etc. ・It is a harmonic countermeasure product. -The case has been changed to a resin case. The mounting hole dimensions are the same as the old model (LEG-170L/173L series). ・Select the zero-phase current transformer (ZCT) from the M30, SM41 to SM240, BM30 to BM106, DM55B to DM100M, as well as the ZC series with temporary conductor. Compatible. However, LEG-193L and DM55B are not compatible, so they will be shipped in combination with the same serial number. ・This is an environmentally friendly product (compliant with the European RoHS Directive). ■Operation If a leakage occurs in the load side circuit after the zero-phase current transformer is installed, an electromotive force will be generated at the secondary terminal of the zero-phase current transformer. This secondary output is distributed to independent circuits for light leakage and heavy leakage. After adjusting the sensitivity of each, it is amplified by an amplifier circuit, the level is judged by a level detection circuit, and the switching circuit displays the operation display and output contact. Let it work. At this time, since the light leakage is an automatic recovery method, it will recover once the leakage is resolved. If heavy earth leakage is set to auto-reset, only the output contact will return when the earth leakage is resolved. When set to manual recovery, the operation indicator and output contacts will not recover until the test/reset switch is turned to the recovery side even if the leakage is eliminated. Please note that the operation display cannot be reset if the control power is turned off. ■Features ・Protects low-voltage circuit equipment from electrical leakage. ・Two-stage alarm type for light leakage and heavy earth leakage. - Automatic/manual return switching method. ・It is a harmonic countermeasure product. ・Compliant with "JIS C 8374 Earth Leakage Relay".

  • Product

    Two-stage alarm earth leakage relay LEG-193L series

Share this product


50+ people viewing

Last viewed: 9 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Two-stage alarm earth leakage relay LEG-193L series

Product Image Part Number Price (excluding tax) Control power supply voltage Exterior color Frequency Heavy ground fault capacity Inertial dead time Insulation resistance Mass Non-operating current Operating temperature range Operating time setting value Operating time tolerance range (when 100% signal is applied) Operation display Display method Operation display Return method Output contact configuration Output contact return method Output contact switching capacity Power consumption Sensitivity current setting value Sensitivity current tolerance range Test method Withstand voltage Working voltage range
Two-stage alarm earth leakage relay LEG-193L series-Part Number-LEG-193L

LEG-193L

Available upon quote AC100/110V
AC200/220V
Munsell symbol N1.5 50/60Hz Continuous AC600A, max. 5,000A, 2s Light leakage 0.1s
Heavy leakage 0.1-0.3-0.5-0.7-1.0 (s)
20MΩ or more with DC500V megger Approximately 1.0kg Light leakage 0.25-0.5-0.75-1.0-1.25 (A)
Heavy leakage 0.5-1.0-2.5-5.0-10 (A)
-20℃~+50℃ Light leakage 0.3s
Heavy leakage 0.3-0.5-1.0-1.5-2.0 (s)
Light leakage 0.3s within +25%~-50%
Heavy leakage 0.3s within +25%~-50%, 0.5~1.5s within ±25%, 2.0s within +0%~-25%
Light leakage LED display (red)
Heavy leakage mag sign display (orange during operation)
Light leakage automatic recovery method
Heavy leakage manual return method
Light leakage 1a
Heavy leakage 1a,1c
Light leakage automatic recovery method
Heavy leakage automatic/manual return switching
AC110/220V 5A cosφ=1 2/1.5A cosφ=0.4A
DC100V 0.6A L/R=1ms 0.2A L/R=7ms
2.5VA normally, 5VA during operation Light leakage 0.5-1.0-1.5-2.0-2.5 (A)
Heavy leakage 1.0-2.0-5.0-10-20 (A)
51%~100% Test/reset switch (combined) Between control circuit conductive part and outer box 2,000V AC for 1 minute
Between control circuit conductive parts AC1,500V for 1 minute
1,000V AC for 1 minute between open contacts of the same control circuit
AC80~121V
AC160~242V