Product
Ior detection method Earth leakage direction relayHandling Company
Hikari Shoko Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Accessories | Alarm contact Self-diagnosis abnormality alarm | Alarm contact earth leakage monitoring | Ambient temperature range | Control power supply voltage | Earth leakage operation display | Elevation | Exterior color | Heavy ground fault capacity | Inertial dead time | Insulation resistance | Mass | Monitoring circuit setting | Monitoring line frequency | Non-operating current | Operating time setting value | Operating time tolerance | Power consumption | Relative humidity | Self-diagnosis error display | Sensitivity current setting value | Sensitivity current tolerance range | Switching capacity (for each alarm contact) | Test method | Withstand voltage | Working voltage range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LIG-12 |
Available upon quote | Complete set of case mounting nuts (nuts x 2, washers x 2, spring washers x 2) | A1-c1: Automatic recovery method (If the earth leakage monitoring contact was activated in advance, the self-diagnosis abnormality alarm contact will not operate) | A2-c2: Automatic/manual recovery switching (If the self-diagnosis abnormality alarm contact was activated in advance, the earth leakage monitoring contact will not operate) | -10℃~+50℃ | AC100V | Magsign display (orange during operation): Manual return method | 2,000m or less | Munsell symbol N1.5 | Continuous: AC600A Maximum: AC5,000A 2.0s | 0.1-0.3-0.5-0.8-1.6 (s) | 20MΩ or more using a 500V DC megger (conducted at locations where withstand voltage is applied) | Approximately 1.5kg | 1φ2W-1φ3W-3φY-3φ△ (Used circuit voltage is AC440V or less) |
50/60Hz (manual switching) Control power frequency is also the same |
0.1-0.2-0.3-0.4-0.5 (A) | 0.3-0.5-0.8-1.0-2.0 (s) |
0.3-0.5-0.8-1.0 (s): +0.15s~-0.1s 2.0s: +0s~-0.3s When a current of 100% of the current setting value is applied |
Always: 6VA or less Operating: 7VA or less |
45~85% | Light emitting diode display (red): Automatic recovery method | 0.2-0.4-0.6-0.8-1.0 (A) | 51~100% |
AC110V: 5A (cosφ=1), 2A (cosφ=0.4) DC100V: 0.4A (L/R=1ms),0.1A (L/R=7ms) |
Test switch Automatic self-diagnosis method |
AC2,000V for 1 minute between control circuit conductive part and outer box AC1,500V for 1 minute Between conductive parts of control circuits (excluding between input circuits) 1,000V AC for 1 minute between open contacts of the same control circuit |
AC80V~110V |