Product
Liquid and paste pressure measurement equipment Static pressure type meter DeltaPilot FMB52Handling Company
Endress+Hauser Group Services AGProduct Image | Part Number | Price (excluding tax) | Ambient temperature | Characteristic | Class certification | Design certification | Drinking water authentication | Features | Gasket material | Housing material | Inclusion solution | Long -term stability | Maximum overpressure limit | Maximum turndown | Measurement principle | Measuring cell | Minimum calibration span | Process connection | Process menblene material | Process temperature | Safety certification | Standard accuracy | Standard conformity certificate/authentication | Supply voltage | Vacuum resistance | communication |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DeltaPilot FMB52 |
Available upon quote |
-40 ° C ... 85 ° C (-40 ° f ... 185 ° f) |
With pressure transmission device for static pressure level measurement, with flash mount type metal Contite measuring cell: Completely airtight, condensation resistance, liner resistance, low temperature effects Rope extension type |
GL/ ABS/ LR/ BV/ DNV |
EN10204-3.1 NACE MRO175 |
KTW/ NSF/ ACS |
Sharing parts by module concept in differential pressure and process pressure devices (replacement display, common electronic insert) Diagnostic function |
Biton, EPDM, Carretz, None | SUS316L equivalent, die -cast aluminum |
Intructible oil, Synthetic lubricating oil |
0.05 %/year of URL | 4 MPA (600 PSI) | 100: 1 | Static pressure |
10 kpa ... 1 mpa (1.5psi ... 150psi) |
1 kpa (1.45 PSI) |
screw: G1 1/2, mnpt1 1/2 Flange: DN40 ... DN100, ASME 2 "... 4", JIS 10K |
Equivalent to SUS316L, Aloy C, Gold-Radium PE, Fep |
PE cable: -10 ° C ... 70 ° C / 14 ° f ... 158 ° f FEP cable: -10 ° C ... 80 ° C / 14 ° f ... 176 ° f |
Overflow prevention WHG SIL |
Standard: 0.2% Options: 0.1% |
ATEX, FM, CSA, CSA C/US, IEC EX, Inmetro, Nepsi, UK EX |
4 ... 20 ma mount DC 10.5 ... 45 v (Non -explosion): EX IA: DC 10.5 ... 30 V Profibus PA: DC 9 ... 32 V (non -explosion) Foundation field bus: DC 9 ... 32 V (non -explosion) |
0 KPA Abs. |
4 ~ 20 ma heat Profibus PA Foundation field bus |
Endress+Hauser Group Services AG