Product
Liquid conductivity level switch LIQUIPOINT FTW33Handling Company
Endress+Hauser Group Services AGCategories
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Characteristics / application | Design certification | Features | Major liquid portion | Measurement principle | Power / communication | Process connection | Process pressure / maximum overpressure limit | Process temperature | Sanitari process connection | Sanitation standard conformity certificate | Selection item | Standard conformity certificate/authentication | communication |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LIQUIPOINT FTW33 |
Available upon quote |
-40 ... 70 ° C (-40 ... 158 ° f) |
Compact type level limit switch. Used in piping, stirrer with/ no storage tank, mixed tank, and process tank. Water -based or oil -based measurement, with adhesive compensation function, flash mount. | EN 10204-3.1 |
For CIP and SIP Conductive foam can be detected and switch off. Power / communication DC 10 ... 30 V Ambient temperature -40 ... 70 ° C (-40 ... 158 ° f) Process temperature standard: -20 ... 100 ° C Washing: -20 ... 150 ° C 1 hour (-4 ... 302 ° f 1 hour) Process pressure / maximum overpressure limit Vacuum ... 2.5 mpa (Vacuum ... 362.5 PSI) Major liquid portion Sensor: SUS316L equivalent Sensor Insulation: PEEK |
Sensor: SUS316L equivalent Sensor Insulation: PEEK |
Conductivity | DC 10 ... 30 V | Neji G1, G1/2, G3/4, M24 |
Vacuum ... 2.5 mpa (Vacuum ... 362.5 PSI) |
standard: -20 ... 100 ° C Washing: -20 ... 150 ° C 1 hour (-4 ... 302 ° f 1 hour) |
Clamp ISO 2852 1 to 1/2 ", 2", DIN11851 Pipe Union |
3A, EHEDG |
Welding adapter, Sanitari process connection process adapter |
CSA C/US | DC PNP |
Endress+Hauser Group Services AG