Converter that enables the use of Memosens sensors at Lab Far Menta ◾️ Application The Memosens analog converter CYM17 allows you to use a digital MEMOSENS sensor in the labofer mentor application without changing the SOP. Memosens digital technology maximizes the consistency between processes and data, and has a simple operability. Eliminates dew condensation issues due to moisture and guarantee a stable signal after autoclave. The Memosens analog converter CYM17 allows you to use the digital Memosens sensor in the existing Farmet of the biotechnology industrial lab. ◾️Anucial ・ Easy to exchange with existing analog sensors. All you have to do is set up a Memosens sensor in Farmet and connect it to the converter. ・ One Memosens PH sensor (CPS171D, etc.) and one optical oxygen sensor (COS81D, etc.) There are a variety of adapta cables that can be easily connected. ・ Cable connection that is not affected by moisture, corrosion, and adhesion due to Memosens technology Ensure the highest availability of sensors and safety of testing. ・ Memosens sensors are both bench top fhamen or process applications Demonstrates excellent performance. Provides a complete consistency measurement value from the first test in the lab to the final large -scale process. ・ The converter continues to check the Memosens sensor to maintain highly measured reliability. Emit an alarm when an error occurs.

  • Product

    Water quality analysis meter Memosens analog converter CYM17




*Please note that we may not be able to accommodate sample requests.

1 Models of Water quality analysis meter Memosens analog converter CYM17

Product Image Part Number Price (excluding tax) External dimensions Material Measurement principle Output / communication Process temperature Protection grade application input
Water quality analysis meter Memosens analog converter CYM17-Part Number-CYM17

CYM17

Available upon quote Height: 36.6 mm (1.44 in)
Depth: 72 mm (2.8 in)
Width: 140.6 mm (5.5 in)
Housing: Aluminum Potential difference measurement Output PH: MV signal complies with Nernst formula (0 MV (pH 7) and -59 MV/pH)
Temperature PH: Simulate PT1000
Output oxygen: 0 to 60 na (100%oxygen saturation: 60 NA)
Temperature oxygen: 22 KOHM NTC simulates
-5 ~+50 ° C (20 ~ 120 ° f) IP54 With the CYM17 converter, you can easily install conventional analog pH/oxygen sensors to Memosens CPS171D and COS81D in bench top fermented applications. M12 socket