Wearing type Multi-type gas detector XA-4400II-New Cosmos Electric

XA-4400II | Wearing type Multi-type gas detector XA-4400II
New Cosmos Electric


Price (excluding tax)

Estimate Required


Model Description

Detection principle Combustible gas: Contact combustion type Oxygen: Galvani battery type Hydrogen sulfide / carbon monoxide: constant potential multi -oxide type Detection range Combustible gas: 0-100%LEL Oxygen: 0 to 25.0vol% Hydrogen sulfide: 0 to 30.0ppm Carbon monoxide: 0-300ppm alarm [Warning setting value] Combustible gas: (1st stage) 10%LEL (2nd stage) 30%LEL Oxygen: (1st stage) 19.5vol%(2nd stage) 18.0vol% Hydrogen sulfide: (1st stage) 10.0ppm (2nd stage) 15.0ppm Carbon monoxide: (1st stage) 50 ppm (second stage) 150pm [Warning method] Buzzer sounding, red lamp flashing, vibration, LCD display (automatic return) Continuous use time About 40 hours (long life mode ON) / about 20 hours (when long life mode is OFF) / about 1200 hours (for models without combustible gas detection) * 25 ° C, no alarm / backlight lights out


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Detection range

Gas collection method

Protection grade

Target gas

alarm

mass

size

See all 2 models in list
  • Part Number

    XA-4400II




*Please note that we may not be able to accommodate sample requests.

Wearing type Multi-type gas detector XA-4400II XA-4400II's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Detection range Gas collection method Protection grade Target gas alarm mass size
Wearing type Multi-type gas detector XA-4400II-Part Number-XA-4400II Available upon quote Combustible gas: 0 to 100%LEL oxygen: 0 to 25.0vol%hydrogen sulfide: 0 to 30.0 ppm carbon monoxide: 0 to 300 ppm Automatic suction type Equivalent to IP67 Flashy gas (methane or isobutan), oxygen, hydrogen sulfide, carbon monoxide [Warning setting value] combustible gas: (1st stage) 10%LEL (second stage) 30%LEL oxygen: 19.5vol%(1st stage) 18.0vol%hydrogen sulfide: (1st stage) 10.0 ppm (second stage) 15.0 ppm carbon monoxide: 2nd stage) 150PPM [Warning method] Buzzer sound, red lamp flashing, vibration, LCD display (automatic return) Approximately 130g W70 x H72 x D26mm

There are 2 models for this product.

Customers who viewed this product also viewed

Other products of New Cosmos Electric


View more products of New Cosmos Electric

About Company Handling This Product

New Cosmos Electric

  • Japan
  • 467 employees

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.