Price (excluding tax)
$41.60
・ No mounting work required (glow, lapid) ・ It can be used directly by the AC power supply by wiring work ・ Maximum power consumption reduced by about 62%(compared to fluorescent lamps, our confirmation) ・ Design life 50,000 hours (at 40 ° C) ・ Built -in overcurrent and over -voltage protection circuit ・ Polycarbonate+aluminum frame specification is resistant to impact ・ Control flicker by high frequency lighting
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Admitted color (RA)
All light bundles (when using one light equipment) directly connected to the AC power supply
All light bundles (when using one light) Rapid
All light bundles (when using one light) glow
Beam angle
Color temperature
Color type
Compatible equipment universal compatible
Design life
Directly connected to the power consumption AC power supply (when using one light equipment, please consider it as a guide because there are variations due to the type of stabilizer and LED elements)
Directly under illuminance (when using 1m, 1 light trough equipment) AC power supply directly
Follow -up standard
Immediately under illuminance (when using 1m, 1 light trough equipment) Glow
Immediately under illuminance (when using 1m, 1 light trough equipment) Rapid
Insulation resistance
Lower luminous bundle (when using 1 light trough equipment) Glow
Lower luminous bundle (when using 1 light trough equipment) Rapid
Lower luminous bundle (when using one light trough equipment) directly connected to AC power
Material
Mounting
Operating temperature limit
Power consumption glow (when using one light equipment, please consider it as a guide because there are variations due to the type of stable and LED elements)
Power consumption rapid (When using one light equipment, please consider it as a guide because there are variations due to the type of stabilizer and LED elements)
Supply power supply (when directly connected to AC power)
Tint
Used humidity range
Withstand voltage
mass
Part Number
LS1200D-C1Handling Company
MGMTItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | All light bundles (when using one light equipment) directly connected to the AC power supply | All light bundles (when using one light) Rapid | All light bundles (when using one light) glow | Beam angle | Color temperature | Color type | Compatible equipment universal compatible | Design life | Directly connected to the power consumption AC power supply (when using one light equipment, please consider it as a guide because there are variations due to the type of stabilizer and LED elements) | Directly under illuminance (when using 1m, 1 light trough equipment) AC power supply directly | Follow -up standard | Immediately under illuminance (when using 1m, 1 light trough equipment) Glow | Immediately under illuminance (when using 1m, 1 light trough equipment) Rapid | Insulation resistance | Lower luminous bundle (when using 1 light trough equipment) Glow | Lower luminous bundle (when using 1 light trough equipment) Rapid | Lower luminous bundle (when using one light trough equipment) directly connected to AC power | Material | Mounting | Operating temperature limit | Power consumption glow (when using one light equipment, please consider it as a guide because there are variations due to the type of stable and LED elements) | Power consumption rapid (When using one light equipment, please consider it as a guide because there are variations due to the type of stabilizer and LED elements) | Supply power supply (when directly connected to AC power) | Tint | Used humidity range | Withstand voltage | mass |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ 41.60 | 600lm | 600lm | 600lm | 115 ° | 1500 ~ 1900k | Orange type | ・ 1 glow, 2 lights, 1 lapid, 2 lights, directly connected to AC power supply (compatible fluorescent light compatible format: FL40, FLR40) Note 1) It may not be partially lighted even if it is a compatible device. Note 2) Depending on the shape of the socket, it may not be possible. Note 3) In the case of a two-light type, be sure to replace two at the same time because the use in combination with the direct pipe LED or fluorescent light other than the LS1200-C1 may cause a failure. Note 4) It is recommended to replace equipment that exceeds the legal useful life because it causes the product to fall or fire due to deterioration. Note 5) Cannot be used for inverter equipment. | 50.000 hours (at 40 ° C) (it is time until all light bundles decrease to 70%. It does not guarantee the life of the product.) | 17 ~ 22W | 140LX | Safety standard JISC8147-2-13JISC8154 | 140LX | 140LX | Bound pin-Aluminum frame 4mΩ or more/500VDC | 560lm | 560lm | 560lm | Polycarbonate, aluminum | Mounting on existing fluorescent lamp equipment without any need for construction 1) In the case of glow, be sure to remove the glow lamp. Note 2) In the case of an AC power supply directly, the wiring work of the fluorescent lamp is required. | -25 ~+55 ° C C | 17 ~ 25W | 20-22W (dimming type 30-34W) | 100-240vac (tolerance 90-264vac, 47 ~ 66Hz) | G13 | 20 ~ 90%RH (not condensation) | Bound pin-Aluminum frame 1500VAC 1 minute | Approximately 340g |