Vibration alarm VA -300-Sortec

VA-300A | Vibration alarm VA -300
Sortec


Price (excluding tax)

Estimate Required


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Alarm mode

Alarm reset

Calibration signal

Connection load resistance

Detection method

Digital display

Digital display cycle

External dimensions

Frequency range

Indicating method

Measurement display mode

Measurement range (High)

Measurement range (LOW)

Mounting hole dimensions

Power -on -delay

Signal output

Smoothing constant

Supply voltage

Temperature and humidity range

Terminal stand screw

Warning delay time

Warning relay contact

Warning setting range

weight

See all 3 models in list
  • Part Number

    VA-300A




*Please note that we may not be able to accommodate sample requests.

Vibration alarm VA -300 VA-300A's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Alarm mode Alarm reset Calibration signal Connection load resistance Detection method Digital display Digital display cycle External dimensions Frequency range Indicating method Measurement display mode Measurement range (High) Measurement range (LOW) Mounting hole dimensions Power -on -delay Signal output Smoothing constant Supply voltage Temperature and humidity range Terminal stand screw Warning delay time Warning relay contact Warning setting range weight
Vibration alarm VA -300-Part Number-VA-300A Available upon quote Alarm and trip two -stage alarm The alarm display LED lamp is canceled by the reset button, the relay output is automatic reset. Press the [FS] button to display the maximum value 20Hz 300Ω or less Effective value 31/2 digits, red LED, character height 14mm 1 time/second 96 x 96 x 117 (D) mm 10-8000Hz One strikeout Acceleration type 1-199.9m/S2 0.1-19.99m/S2 92 × 92 (0 ~+0.8) mm Operation 30 seconds after the power is turned on Red LED lamp lighting when alarm occurs, yellow LED lamp lighting, trip occurs About 5 seconds Acout2vrms (maximum instruction) DCOUT2V (maximum instruction) 0-45 ° C, 95 % RH or less (main unit only) (only for the main body) -10 to 60 ° C, 95 % RH or less (main body only) 3.5mm Alarm [Can be set in 2-30 seconds, 2 seconds step] Trip [Output about 2 seconds later after alarm alarm] Trans -focusing point each route, contact capacity is a resistance load, DC24V5AAC100V5A From 1/20 of the maximum value of each measurement range to the maximum measurement limit 400g

There are 3 models for this product.

Customers who viewed this product also viewed

Other products of Sortec


View more products of Sortec

About Company Handling This Product

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree