Price (excluding tax)
Estimate Required
Model Description
The MET ONE MODEL R4800/R4900 is a remote particle counter for monitoring fine particles, which is indispensable for maintaining the cleansing of clean rooms in sterile drug manufacturing equipment and semiconductor factories. The cleanliness is installed in the area where you want to measure, and the measurement result is sent to monitoring software in real time by communication. By constantly monitoring 24 hours a day, it is useful for early detection of deviation.
Product Summary
・ Remote particle counter ideal for cleanliness intensive monitoring system
We will propose the optimal model for the use of 0.3 or 0.5 μm sensitivity 2.83 liters / min, 28.3 liters of large suction, etc., etc.
・ Abundant models (R4803/4805/4815) (R4903/4905/4915)
・ Small and lightweight and stable performance
・ Easy to understand in the event of a sensor error or failure
・ Calonials and inspections can be performed locally
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Battery
5 hours consecutive (3.5 hours charging) | Handheld Central Particle Counter MET ONE HHPC 2+
5 hours consecutive (3.5 hours charging) | Handheld Central Particle Counter MET ONE HHPC 3+
5 hours consecutive (3.5 hours charging) | Handheld Central Particle Counter MET ONE HHPC 6+
6 hours (when 2 batteries are installed) | Kien Particle Counter MET ONE3413
6 hours (when 2 batteries are installed) | Kien Particle Counter MET ONE3423
6 hours (when 2 batteries are installed) | Kien Particle Counter MET ONE3415
6 hours (when 2 batteries are installed) | Kien Particle Counter MET ONE3425
3 hours | Kien Particle Counter MET ONE3445
3 hours | Kien Particle Counter MET ONE3411
Data memory
10,000 times | Handheld Central Particle Counter MET ONE HHPC 2+
10,000 times | Handheld Central Particle Counter MET ONE HHPC 3+
10,000 times | Handheld Central Particle Counter MET ONE HHPC 6+
5,000 times | Kien Particle Counter MET ONE3413
5,000 times | Kien Particle Counter MET ONE3423
5,000 times | Kien Particle Counter MET ONE3415
5,000 times | Kien Particle Counter MET ONE3425
5,000 times | Kien Particle Counter MET ONE3445
5,000 times | Kien Particle Counter MET ONE3411
Delay time
3 seconds to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 2+
3 seconds to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 3+
3 seconds to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 6+
6 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3413
6 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3423
6 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3415
6 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3425
6 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3445
6 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3411
Hold time
0 seconds to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 2+
0 seconds to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 3+
0 seconds to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 6+
0 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3413
0 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3423
0 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3415
0 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3425
0 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3445
0 seconds to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3411
Measurement cycle
0 to 999 | Handheld Central Particle Counter MET ONE HHPC 2+
0 to 999 | Handheld Central Particle Counter MET ONE HHPC 3+
0 to 999 | Handheld Central Particle Counter MET ONE HHPC 6+
0-100 cycle | Kien Particle Counter MET ONE3413
0-100 cycle | Kien Particle Counter MET ONE3423
0-100 cycle | Kien Particle Counter MET ONE3415
0-100 cycle | Kien Particle Counter MET ONE3425
0-100 cycle | Kien Particle Counter MET ONE3445
0-100 cycle | Kien Particle Counter MET ONE3411
Measurement particle diameter
0.5 μm (fixed)
A voluntary selection of 1.0/2.0/5.0 μm (2 grain size simultaneous measurement) | Handheld Central Particle Counter MET ONE HHPC 2+
0.3 μm (fixed)
0.5/1.0/2.0/5.0/10.0 μm arbitrarily selected (3 grain size simultaneous measurement) | Handheld Central Particle Counter MET ONE HHPC 3+
0.3/0.5/1.0/2.0/5.0/10.0 μm (simultaneous measurement of 6 gaps)
Suction flow rate 2.83ℓ/minute | Handheld Central Particle Counter MET ONE HHPC 6+
0.3/0.5/1.0/3.0/5.0/10.0 μm | Kien Particle Counter MET ONE3413
0.3/0.5/1.0/3.0/5.0/10.0 μm | Kien Particle Counter MET ONE3423
0.5/1.0/2.0/3.0/5.0/10.0 or 25.0μm | Kien Particle Counter MET ONE3415
0.5/1.0/2.0/3.0/5.0/10.0 or 25.0μm | Kien Particle Counter MET ONE3425
0.5/1.0/2.0/3.0/5.0/10.0 μm | Kien Particle Counter MET ONE3445
0.1/0.2/0.3/0.5/1.0/5.0 μm | Kien Particle Counter MET ONE3411
0.3/0.5μm | Remote Particle Counter MET ONER4803
0.5/5.0μm | Remote Particle Counter MET ONER4805
0.5/5.0μm | Remote Particle Counter MET ONER4815
0.3/0.5μm | Remote Particle Counter MET ONER4903
0.5/5.0μm | Remote Particle Counter MET ONER4905
0.5/5.0μm
Standard 2 grain diameter option 4 grain size
( * Excluding Pulse model)
0.3/0.5μm 0.3/0.5/1.0/5.0 μm | Remote Particle Counter MET ONE6003
Standard 2 grain diameter option 4 grain size
( * Excluding Pulse model)
0.5/5.0μm 0.5/1.0/5.0/10.0 μm | Remote Particle Counter MET ONE6005
Standard 2 grain diameter option 4 grain size
( * Excluding Pulse model)
0.3/0.5μm 0.3/0.5/1.0/5.0 μm | Remote Particle Counter MET ONE6013
Standard 2 grain diameter option 4 grain size
( * Excluding Pulse model)
0.5/5.0μm 0.5/1.0/5.0/10.0 μm | Remote Particle Counter MET ONE6015
Standard 2 grain diameter option 4 gaps (Ethernet model)
0.5/5.0μm 0.5/1.0/5.0/10.0 μm | Built -in remote party counter MET ONE6015P
Sample time
1 second to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 2+
1 second to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 3+
1 second to 23 hours 59 minutes 59 seconds | Handheld Central Particle Counter MET ONE HHPC 6+
1 second to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3413
1 second to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3423
1 second to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3415
1 second to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3425
1 second to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3445
1 second to 23 hours 59 minutes 59 seconds | Kien Particle Counter MET ONE3411
Standard accessories
Purge filter, Purge filter adapter,
AC adapter, USB cable (A-mini-b),
Inspection results, calibration certificate, traceability systemem,
carrying case | Handheld Central Particle Counter MET ONE HHPC 2+
Purge filter, Purge filter adapter,
AC adapter, USB cable (A-mini-b),
Inspection results, calibration certificate, traceability systemem,
carrying case | Handheld Central Particle Counter MET ONE HHPC 3+
Purge filter, Purge filter adapter,
AC adapter, USB cable (A-mini-b),
Inspection results, calibration certificate, traceability systemem,
carrying case,
Communication stand | Handheld Central Particle Counter MET ONE HHPC 6+
Speed suction probe, one Li-ion battery,
Purge filter, printer paper (normal paper 2 volumes),
Sampling tube, USB flash memory,
AC adapter, instructions | Kien Particle Counter MET ONE3413
Speed suction probe, one Li-ion battery,
Purge filter, printer paper (normal paper 2 volumes),
Sampling tube, USB flash memory,
AC adapter, instructions | Kien Particle Counter MET ONE3423
Speed suction probe, one Li-ion battery,
Purge filter, printer paper (normal paper 2 volumes),
Sampling tube, USB flash memory,
AC adapter, instructions | Kien Particle Counter MET ONE3415
Speed suction probe, one Li-ion battery,
Purge filter, printer paper (normal paper 2 volumes),
Sampling tube, USB flash memory,
AC adapter, instructions | Kien Particle Counter MET ONE3425
Correspondence suction probe, two Li-ion batteries,
Purge filter, printer paper (normal paper 2 volumes),
Sampling tube, USB flash memory,
AC adapter, instruction manual | Kien Particle Counter MET ONE3445
Correspondence suction probe, two Li-ion batteries,
Purge filter, printer paper (normal paper 2 volumes),
Sampling tube, USB flash memory,
AC adapter, instructions | Kien Particle Counter MET ONE3411
Suction flow rate
2.83ℓ/minute | Handheld Central Particle Counter MET ONE HHPC 2+
2.83ℓ/minute | Handheld Central Particle Counter MET ONE HHPC 3+
2.83ℓ/minute | Handheld Central Particle Counter MET ONE HHPC 6+
28.3ℓ/minute | Kien Particle Counter MET ONE3413
50ℓ/minute | Kien Particle Counter MET ONE3423
28.3ℓ/minute | Kien Particle Counter MET ONE3415
50ℓ/minute | Kien Particle Counter MET ONE3425
100ℓ/minute | Kien Particle Counter MET ONE3445
28.3ℓ/minute | Kien Particle Counter MET ONE3411
2.83ℓ/minute | Remote Particle Counter MET ONER4803
2.83ℓ/minute | Remote Particle Counter MET ONER4805
28.3ℓ/minute | Remote Particle Counter MET ONER4815
2.83ℓ/minute | Remote Particle Counter MET ONER4903
2.83ℓ/minute | Remote Particle Counter MET ONER4905
28.3ℓ/minute
2.83ℓ/minute | Remote Particle Counter MET ONE6003
2.83ℓ/minute | Remote Particle Counter MET ONE6005
28.3ℓ/minute | Remote Particle Counter MET ONE6013
28.3ℓ/minute | Remote Particle Counter MET ONE6015
28.3ℓ/minute | Built -in remote party counter MET ONE6015P
The same clock number error difference
less than 10,
Maximum concentration 70,000,000 pieces/m3
(2,000,000 pieces/28.3ℓ) | Handheld Central Particle Counter MET ONE HHPC 2+
less than 10,
Maximum concentration 140,000,000/M3
(4,000,000 pieces/28.3ℓ) | Handheld Central Particle Counter MET ONE HHPC 3+
"less than 10,
Maximum concentration 140,000,000/M3
(4,000,000 pieces/28.3ℓ) | Handheld Central Particle Counter MET ONE HHPC 6+
28.3ℓ model: 10 % or less,
Maximum concentration 20,000,000/M3
(566,570 pieces/28.3ℓ)
50ℓ model: 10 % or less,
Maximum concentration 10,000,000/M3
(283,280 pieces/28.3ℓ) | Kien Particle Counter MET ONE3413
28.3ℓ model: 10 % or less,
Maximum concentration 20,000,000/M3
(566,570 pieces/28.3ℓ)
50ℓ model: 10 % or less,
Maximum concentration 10,000,000/M3
(283,280 pieces/28.3ℓ) | Kien Particle Counter MET ONE3423
28.3ℓ model: 10 % or less,
Maximum concentration 20,000,000/M3
(566,570 pieces/28.3ℓ)
50ℓ model: 10 % or less,
Maximum concentration 10,000,000/M3
(283,280 pieces/28.3ℓ) | Kien Particle Counter MET ONE3415
28.3ℓ model: 10 % or less,
Maximum concentration 20,000,000/M3
(566,570 pieces/28.3ℓ)
50ℓ model: 10 % or less,
Maximum concentration 10,000,000/M3
(283,280 pieces/28.3ℓ) | Kien Particle Counter MET ONE3425
less than 10,
Maximum concentration 5,000,000 pieces/m (141,640 pieces/28.3ℓ) | Kien Particle Counter MET ONE3445
less than 10,
Maximum concentration 3,500,000 pieces/m (100,000 pieces/28.3ℓ) | Kien Particle Counter MET ONE3411
less than 10,
Maximum concentration 140,000,000/M3
(4,000,000 pieces/28.3ℓ) | Remote Particle Counter MET ONER4803
less than 10,
Maximum concentration 140,000,000/M3
(4,000,000 pieces/28.3ℓ) | Remote Particle Counter MET ONER4805
less than 10,
Maximum concentration 28,000,000/M3
(800,000 pieces/28.3ℓ) | Remote Particle Counter MET ONER4815
less than 10,
Maximum concentration 140,000,000/M3
(4,000,000 pieces/28.3ℓ) | Remote Particle Counter MET ONER4903
less than 10,
Maximum concentration 140,000,000/M3
(4,000,000 pieces/28.3ℓ) | Remote Particle Counter MET ONER4905
less than 10,
Maximum concentration 28,000,000/M3
(800,000 pieces/28.3ℓ)
less than 10,
Maximum concentration 140,000,000/M3
(4,000,000 pieces/28.3ℓ) | Remote Particle Counter MET ONE6003
less than 10,
Maximum concentration 140,000,000/M3
(4,000,000 pieces/28.3ℓ) | Remote Particle Counter MET ONE6005
less than 10,
Maximum concentration 20,000,000/M3
(566,000 pieces/28.3ℓ) | Remote Particle Counter MET ONE6013
less than 10,
Maximum concentration 20,000,000/M3
(566,000 pieces/28.3ℓ) | Remote Particle Counter MET ONE6015
less than 10,
Maximum concentration 20,000,000/M3
(566,000 pieces/28.3ℓ) | Built -in remote party counter MET ONE6015P
display
3.5 inch color LCD panel (LED backlight type) | Handheld Central Particle Counter MET ONE HHPC 2+
3.5 inch color LCD panel (LED backlight type) | Handheld Central Particle Counter MET ONE HHPC 3+
3.5 inch color LCD panel (LED backlight type) | Handheld Central Particle Counter MET ONE HHPC 6+
Color touch screen, 1/4VGA TFT | Kien Particle Counter MET ONE3413
Color touch screen, 1/4VGA TFT | Kien Particle Counter MET ONE3423
Color touch screen, 1/4VGA TFT | Kien Particle Counter MET ONE3415
Color touch screen, 1/4VGA TFT | Kien Particle Counter MET ONE3425
Color touch screen, 1/4VGA TFT | Kien Particle Counter MET ONE3445
Color touch screen, 1/4VGA TFT | Kien Particle Counter MET ONE3411
light source
Semiconductor laser | Handheld Central Particle Counter MET ONE HHPC 2+
Semiconductor laser | Handheld Central Particle Counter MET ONE HHPC 3+
Semiconductor laser | Handheld Central Particle Counter MET ONE HHPC 6+
Semiconductor laser | Kien Particle Counter MET ONE3413
Semiconductor laser | Kien Particle Counter MET ONE3423
Semiconductor laser | Kien Particle Counter MET ONE3415
Semiconductor laser | Kien Particle Counter MET ONE3425
Semiconductor laser | Kien Particle Counter MET ONE3445
HENE laser | Kien Particle Counter MET ONE3411
Semiconductor laser | Remote Particle Counter MET ONER4803
Semiconductor laser | Remote Particle Counter MET ONER4805
Semiconductor laser | Remote Particle Counter MET ONER4815
Semiconductor laser | Remote Particle Counter MET ONER4903
Semiconductor laser | Remote Particle Counter MET ONER4905
Semiconductor laser
Semiconductor laser | Remote Particle Counter MET ONE6003
Semiconductor laser | Remote Particle Counter MET ONE6005
Semiconductor laser | Remote Particle Counter MET ONE6013
Semiconductor laser | Remote Particle Counter MET ONE6015
Semiconductor laser | Built -in remote party counter MET ONE6015P
output
USB, Ethernet | Handheld Central Particle Counter MET ONE HHPC 2+
USB, Ethernet | Handheld Central Particle Counter MET ONE HHPC 3+
USB, Ethernet | Handheld Central Particle Counter MET ONE HHPC 6+
USB client, USB host, Ethernet | Kien Particle Counter MET ONE3413
USB client, USB host, Ethernet | Kien Particle Counter MET ONE3423
USB client, USB host, Ethernet | Kien Particle Counter MET ONE3415
USB client, USB host, Ethernet | Kien Particle Counter MET ONE3425
USB client, USB host, Ethernet,
RS-232C, RS-485, PDF (optional) | Kien Particle Counter MET ONE3445
USB client, USB host, Ethernet,
RS-232C, RS-485, PDF (optional) | Kien Particle Counter MET ONE3411
RS-485 | Remote Particle Counter MET ONER4803
RS-485 | Remote Particle Counter MET ONER4805
RS-485 | Remote Particle Counter MET ONER4815
DC4-20MA | Remote Particle Counter MET ONER4903
DC4-20MA | Remote Particle Counter MET ONER4905
DC4-20MA
Ethernet, 4-20ma, Pulse, RS-232C,
RS485 (MODBUS RTU or FXB) | Remote Particle Counter MET ONE6003
Ethernet, 4-20ma, Pulse, RS-232C,
RS485 (MODBUS RTU or FXB) | Remote Particle Counter MET ONE6005
Ethernet, 4-20ma, Pulse, RS-232C,
RS485 (MODBUS RTU or FXB) | Remote Particle Counter MET ONE6013
Ethernet, 4-20ma, Pulse, RS-232C,
RS485 (MODBUS RTU or FXB) | Remote Particle Counter MET ONE6015
Ethernet, 4-20ma, Serial (RS232C/RS485), pulse | Built -in remote party counter MET ONE6015P
size
245 (H) x 99 (W) x 53 (D) * Excluding protrusions | Handheld Central Particle Counter MET ONE HHPC 2+
245 (H) x 99 (W) x 53 (D) * Excluding protrusions | Handheld Central Particle Counter MET ONE HHPC 3+
245 (H) x 99 (W) x 53 (D) * Excluding protrusions | Handheld Central Particle Counter MET ONE HHPC 6+
318 (W) x 254 (D) x 203 (H) mm | Kien Particle Counter MET ONE3413
318 (W) x 254 (D) x 203 (H) mm | Kien Particle Counter MET ONE3423
318 (W) x 254 (D) x 203 (H) mm | Kien Particle Counter MET ONE3415
318 (W) x 254 (D) x 203 (H) mm | Kien Particle Counter MET ONE3425
318 (W) x 254 (D) x 203 (H) mm | Kien Particle Counter MET ONE3445
330 (W) x 559 (D) x 229 (H) mm | Kien Particle Counter MET ONE3411
94 (W) x 38 (D) x 47 (H) mm | Remote Particle Counter MET ONER4803
94 (W) x 38 (D) x 47 (H) mm | Remote Particle Counter MET ONER4805
94 (W) x 38 (D) x 47 (H) mm | Remote Particle Counter MET ONER4815
94 (W) x 38 (D) x 47 (H) mm | Remote Particle Counter MET ONER4903
94 (W) x 38 (D) x 47 (H) mm | Remote Particle Counter MET ONER4905
94 (W) x 38 (D) x 47 (H) mm
135.6 (W) x 89.3 (D) x 120.6 (H) mm | Remote Particle Counter MET ONE6003
135.6 (W) x 89.3 (D) x 120.6 (H) mm | Remote Particle Counter MET ONE6005
135.6 (W) x 89.3 (D) x 120.6 (H) mm | Remote Particle Counter MET ONE6013
135.6 (W) x 89.3 (D) x 120.6 (H) mm | Remote Particle Counter MET ONE6015
170 (W) x 318 (D) x 102 (H) mm | Built -in remote party counter MET ONE6015P
191 (W) x 57 (φ) mm | High -pressure diffuser for MET ONE Particle Counter
weight
Approximately 690g | Handheld Central Particle Counter MET ONE HHPC 2+
Approximately 690g | Handheld Central Particle Counter MET ONE HHPC 3+
Approximately 690g | Handheld Central Particle Counter MET ONE HHPC 6+
7.55kg | Kien Particle Counter MET ONE3413
8.33kg | Kien Particle Counter MET ONE3423
7.55kg | Kien Particle Counter MET ONE3415
8.33kg | Kien Particle Counter MET ONE3425
8.65kg | Kien Particle Counter MET ONE3445
15.9kg | Kien Particle Counter MET ONE3411
0.3kg | Remote Particle Counter MET ONER4803
0.3kg | Remote Particle Counter MET ONER4805
0.3kg | Remote Particle Counter MET ONER4815
0.3kg | Remote Particle Counter MET ONER4903
0.3kg | Remote Particle Counter MET ONER4905
0.3kg
0.82kg | Remote Particle Counter MET ONE6003
0.82kg | Remote Particle Counter MET ONE6005
0.82kg | Remote Particle Counter MET ONE6013
0.82kg | Remote Particle Counter MET ONE6015
4.62kg | Built -in remote party counter MET ONE6015P
Housing material
Stainless steel housing | Kien Particle Counter MET ONE3413
Stainless steel housing | Kien Particle Counter MET ONE3423
Stainless steel housing | Kien Particle Counter MET ONE3415
Stainless steel housing | Kien Particle Counter MET ONE3425
Stainless steel housing | Kien Particle Counter MET ONE3411
SUS304 | Remote Particle Counter MET ONE6003
SUS304 | Remote Particle Counter MET ONE6005
SUS304 | Remote Particle Counter MET ONE6013
SUS304 | Remote Particle Counter MET ONE6015
SUS304 | Built -in remote party counter MET ONE6015P
Measurement location ID
0 to 999 | Kien Particle Counter MET ONE3413
0 to 999 | Kien Particle Counter MET ONE3423
0 to 999 | Kien Particle Counter MET ONE3415
0 to 999 | Kien Particle Counter MET ONE3425
0 to 999 | Kien Particle Counter MET ONE3445
0 to 999 | Kien Particle Counter MET ONE3411
Optional gas measurement
nitrogen | Kien Particle Counter MET ONE3413
nitrogen | Kien Particle Counter MET ONE3423
nitrogen | Kien Particle Counter MET ONE3415
nitrogen | Kien Particle Counter MET ONE3425
nitrogen | Kien Particle Counter MET ONE3411
Printer
Built -in heat printer | Kien Particle Counter MET ONE3445
Built -in heat printer | Kien Particle Counter MET ONE3411
Flow rate adjustment
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONER4803
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONER4805
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONER4815
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONER4903
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONER4905
Critical Olifice
(-0.051MPa = -380mmHg or higher.)
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONE6003
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONE6005
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONE6013
Critical Olifice
(-0.051MPa = -380mmHg or higher.) | Remote Particle Counter MET ONE6015
Operating environment
Temperature 12-29 ° C, humidity 20-95 % (without condensation) | Remote Particle Counter MET ONER4803
Temperature 12-29 ° C, humidity 20-95 % (without condensation) | Remote Particle Counter MET ONER4805
Temperature 12-29 ° C, humidity 20-95 % (without condensation) | Remote Particle Counter MET ONER4815
Temperature 12-29 ° C, humidity 20-95 % (without condensation) | Remote Particle Counter MET ONER4903
Temperature 12-29 ° C, humidity 20-95 % (without condensation) | Remote Particle Counter MET ONER4905
Temperature 12-29 ° C, humidity 20-95 % (without condensation)
Temperature 10-32 ° C, humidity 5-95 % (without condensation) | Remote Particle Counter MET ONE6003
Temperature 10-32 ° C, humidity 5-95 % (without condensation) | Remote Particle Counter MET ONE6005
Temperature 10-32 ° C, humidity 5-95 % (without condensation) | Remote Particle Counter MET ONE6013
Temperature 10-32 ° C, humidity 5-95 % (without condensation) | Remote Particle Counter MET ONE6015
Temperature 10-32 ° C, humidity 5-95 % (without condensation) | Built -in remote party counter MET ONE6015P
Storage environment
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) | Remote Particle Counter MET ONER4803
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) | Remote Particle Counter MET ONER4805
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) | Remote Particle Counter MET ONER4815
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) | Remote Particle Counter MET ONER4903
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) | Remote Particle Counter MET ONER4905
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation)
Temperature -40-70 ° C, humidity 5-98 % (without condensation) | Remote Particle Counter MET ONE6003
Temperature -40-70 ° C, humidity 5-98 % (without condensation) | Remote Particle Counter MET ONE6005
Temperature -40-70 ° C, humidity 5-98 % (without condensation) | Remote Particle Counter MET ONE6013
Temperature -40-70 ° C, humidity 5-98 % (without condensation) | Remote Particle Counter MET ONE6015
power supply
DC6V@ <250ma | Remote Particle Counter MET ONER4803
DC6V@ <250ma | Remote Particle Counter MET ONER4805
DC6V@ <250ma | Remote Particle Counter MET ONER4815
DC6V@ <250ma | Remote Particle Counter MET ONER4903
DC6V@ <250ma | Remote Particle Counter MET ONER4905
DC6V@ <250ma
DC9-28V | Remote Particle Counter MET ONE6003
DC9-28V | Remote Particle Counter MET ONE6005
DC9-28V | Remote Particle Counter MET ONE6013
DC9-28V | Remote Particle Counter MET ONE6015
DC24V (up to 60W), AC100-240V (up to 150W) | Built -in remote party counter MET ONE6015P
Flow rate
Automatic adjustment (built -in pressure sensor) | Built -in remote party counter MET ONE6015P
LED output
Count alarm, sensor fail, communication failure,
Flow rate fail | Built -in remote party counter MET ONE6015P
Material
stainless | High -pressure diffuser for MET ONE Particle Counter
Sampling diversion
2.83ℓ/minute type, 28.3ℓ/minute type
50ℓ/minute type, 100ℓ/minute type | High -pressure diffuser for MET ONE Particle Counter
pressure
30psi to 150psi | High -pressure diffuser for MET ONE Particle Counter
Compatible models
227 Series/237 Series/2400/2408/3400 Series
(Depending on the revision of EPROM, it may not be supported. For more information, please contact us.) | Particle logger
227 Series/237 Series/2400/2408/3400 Series
(Depending on the revision of EPROM, it may not be supported. For more information, please contact us.) | Particle Logger II
227 series, 237 series, 2400/2408, 3400 series
(Depending on the revision of EPROM, please contact us for details.) | Particle View (Japanese version)
3400 series/manifold/R4800 series/6000 series | Clean purifying intensive monitoring system monitoring software "CMS"
Number of connections
One | Particle logger
Up to 6 units | Particle Logger II
Recommended hardware
Intel Pentium IV, 1GHz, 4GB or more empty hard disk memory 256MB, RS-232 port or USB port | Particle logger
Intel Pentium IV, 1GHz, 4GB or more empty hard disk memory 256MB, RS-232 port or USB port | Particle Logger II
Intel Pentium IV, 1GHz, 4GB or more empty hard disk memory 256MB, RS-232 port or USB port | Particle View (Japanese version)
Start measurement
Can be stopped from the computer | Particle logger
Can be stopped from the computer | Particle Logger II
Supported OS
Windows® 7, Windows® 2000Pro (SP1 or later), XP, Vista, InternetExplore® 5 or later | Particle logger
Windows® 7, Windows® 2000Pro (SP1 or later), XP, Vista, InternetExplore® 5 or later | Particle Logger II
Windows® 2000Pro (SP1 or later), XP, Vista and InternetExplore® 5 or later | Particle View (Japanese version)
Alarm cleanliness
Upper limit 2 level (HIHI/hi), analog upper lower limit 1 level (HI/LO) | Clean purifying intensive monitoring system monitoring software "CMS"
Daily/Total processing
Average, maximum, minimum, and standard deviation in an arbitrary period,
File output is also possible in CSV format | Clean purifying intensive monitoring system monitoring software "CMS"
Number of measurement points
Clean cleaning + analog | Clean purifying intensive monitoring system monitoring software "CMS"
See all 25 models in list
Part Number