Product
UFA separate converter for vane type FA sensor IP65 aluminum housing type/LDG16 DIN rail mounting typeHandling Company
Centronic Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Alarm output | Analog output | Connector | EMC | External dimensions | Forward/reverse (±) direction output | Input sensor | Insulation function | Integrated flow output | Material | Model | Mounting method | Operating temperature range | PC interface RS232 | Power supply | Protection class | Relay output | Self-diagnosis function (NAMUR NE43 compliant) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UFA-LDG16 |
Available upon quote |
Flow velocity < alarm setpoint: Relay is in reset position Flow rate > Alarm setpoint: Relay in working position |
Current output | Screw fastening method according to DIN VDE 0100, according to VGB4, cable 0.14 ~ 4 mm2 | EN61 000-6-2 / IEC77 | W/H/D = 55 / 75 / 110mm, |
+: Relay is in reset position -: Relay is in working position |
Probe type: ZS, ZSR (with forward/reverse function), Pipe-mounted vane sensor: FA-Di, FAR-Di, (with forward/reverse direction function) |
The output signal is electrically isolated from the power supply. |
Pulse frequency 1 Hz per flow rate, Setting example: 1,10 or 100 Nm3 per pulse, pulse width 0.1 s |
Made of Macrolon resin | UFA | 35mm DIN rail mounting method or wall screw mounting method | 0~+50℃ | Used for calibration and various settings. Open the front cover and connect the cable to the RJ22 connector. | 24 V DC (20 ~ 27 V DC), output <5 W | IP20, IEC529/EN60 529 compliant | Max. 300 mA / 27 V DC |
Error signal: 4-20 mA Output type: < 3.6 mA, LED on (yellow) When power is normal: LED lights green Flow velocity sensor input value > 0m/s: LED blinking green |